Server Immersion Cooling Dielectric Coolants Bitcoin Cooler Unit
Server Immersion Cooling Dielectric Coolants Bitcoin Cooler Unit
What's Immersion Cooling?
Immersion cooling refers to the process of immersing servers, GPUs, ASICs, and other IT hardware in a non-conductive fluid. The fluid is a far more effective cooling medium than air is and so higher efficiencies are achievable. Two-phase immersion cooling is similar but the fluid boils on the hot components.
Benefits of Immersion Cooling:
Reduce Operating Costs by 50%+
Power reduction by removing the fans from the miners (~18% – 25%)
Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%)
Increase the hash rate of your current equipment
Increase hardware lifespan
Increase the density of miners in your facility
Built in fire protection as our dielectric fluid is non-flammable
Technical parameter of dry cooler
Dry cooler D3 series parameter(fin space 2.1mm)
| Type |
D3-042- 1X800 |
D3-046- 1X800 |
D3-051- 1X800 |
D3-087- 2X800 |
D3-094- 2X800 |
D3-103- 2X800 |
D3-125- 3X800 |
D3-146- 3X800 |
D3-153- 3X800 |
D3-175- 4X800 |
D3-188- 4X800 |
||||||
| Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | KW | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | |
| outlet | 40℃ | ||||||||||||||||
| 20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||||
| outlet | 40℃ | ||||||||||||||||
| Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||||
| Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||||
| Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||||
| Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||||
| A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||||
| Fan | No X φ |
1x1 x800 |
1x1 x800 |
1x1 x800 |
1x2 x800 |
1x2 x800 |
1x2 x800 |
1x3 x800 |
1x3 x800 |
1x3 x800 |
2x2 x800 |
2x2 x800 |
|||||
| Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||||
| 10m | |||||||||||||||||
| Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||||
| W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||||
| H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||||
| A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||||
| B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
| B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
| B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||||
| B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
| X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||||
| Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
| Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
| Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 |
|||||
Packing and loading:
![]() |
![]() |
![]() |
![]() |
Some reference:
| Dry cooler case | |
|
Case 1 Chemical plant |
Case 2 Chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h) |
![]() ![]() |
![]() ![]() |
|
Case 3 Communication station As air conditioner outdoor unit in China. |
Case 4 Communication station As air conditioner outdoor unit |
![]() |
![]() |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.