Non Standard Purification Vertical AHU Clean Room Air Handling Units
Non-standard Customization Purification Air Conditioning Unit For PCR Detection
Feature: integral design, simple and convenient installation and operation, inverter compressor, dual EC fan, PLC high precision constant temperature and humidity control. Non-standard design.
Clean operating room air conditioning system solution Ⅰ
l DC frequency conversion outdoor unit + clean operating room air conditioning unit + PLC intelligent control
1,Frequency conversion technology: The DC frequency conversion compressor is used to adjust the operating frequency of the compressor according to the temperature change, which is efficient and energy-saving
2,Low ambient temperature cooling: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;
3,Low temperature air supply: Shenglin's unique technology, through the grading and separate control of the evaporator, reduces the evaporation temperature, and the minimum air supply temperature is 5℃;
4,Precise temperature control: electric reheating and electric preheating are steplessly adjusted by SCR to accurately control the indoor temperature
5,Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20°C.
Air conditioning system solution for clean operating room Ⅱ
l Four-pipe air-cooled heat pump heat recovery unit + clean operating room combined air conditioner + PLC control
Multi-function: four-pipe, frequency conversion adjustment, cooling and heating operation can realize energy recovery at the same time, no need to add a hot water tank to adjust the water capacity on the hot water side;
Low-temperature heating: Adopting jet enthalpy and high-temperature liquid injection technology, heating operation at minus 20℃, and energy efficiency ratio higher than 2.1;
Low temperature refrigeration: EC fan is used to detect the discharge pressure of the compressor to achieve normal refrigeration at -20°C,
Cooling and heating balance: automatic cooling and heating balance under partial cooling and heating load, automatic distribution of refrigerant flow;
System stability: Adopting single four-valve design, consistent operation, mature system technology, stable and reliable operation;
Energy saving and environmental protection: annual heat recovery can be realized, energy recovery can be adjusted, cooling energy efficiency ratio ≥ 4.0, while heat energy efficiency ratio ≥ 5.0, combined cooling and heating energy efficiency ratio ≥ 9.0, operation energy saving effect is more significant ;
Intelligent control: Microcomputer PLC control technology, automatically detects the operating status, and realizes energy-saving operation;
Fault self-check: automatic fault detection system can detect operation faults such as suction and exhaust pressure, exhaust temperature, phase loss and reverse phase, overcurrent and overload;
Unique technology: the perfect combination of single four-way valve design, ultra-low temperature heating design, low temperature refrigeration design, and stable mode conversion.
Clean operating room air conditioning system solution Ⅲ
l Air-cooled heat pump + clean operating room combined air conditioning unit + PLC control
Precise temperature control: DC inverter compressor is used, and the operating power of the compressor is self-matched according to changes in ambient temperature;
Low ambient temperature refrigeration: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;
Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20℃;
Intelligent defrosting: super-cooling ice suppression technology, combined with Sunlin’s unique defrosting module, with frost defrosting, frost-free heating
Smart cloud service: PC client + mobile App real-time monitoring.
Standard AHU model representation method:
Unit quick selection table (air volume)
| Model | Nominal air volume m³/h | Windward area of coil㎡ | Wind speed of the coil(m/s) | |||||
| 2.00 | 2.25 | 2.50 | 2.75 | 3.00 | 3.25 | |||
| m³/h | ||||||||
| SLZK015W | 1500 | 0.16 | 1152 | 1296 | 1440 | 1584 | 1728 | 1872 |
| SLZK018W | 1800 | 0.2 | 1440 | 1620 | 1800 | 1980 | 2160 | 2340 |
| SLZK022W | 2200 | 0.24 | 1728 | 1944 | 2160 | 2376 | 2592 | 2808 |
| SLZK032W | 3200 | 0.35 | 2520 | 2835 | 3150 | 3465 | 3780 | 4095 |
| SLZK038W | 3800 | 0.42 | 3024 | 3402 | 3780 | 4158 | 4536 | 4914 |
| SLZK050W | 5000 | 0.56 | 4032 | 4536 | 5040 | 5544 | 6048 | 6552 |
| SLZK063W | 6300 | 0.7 | 5040 | 5670 | 6300 | 6930 | 7560 | 8190 |
| SLZK072W | 7200 | 0.8 | 5760 | 6480 | 7200 | 7920 | 8640 | 9360 |
| SLZK095W | 9500 | 1.04 | 7488 | 8424 | 9360 | 10296 | 11232 | 12168 |
| SLZK120W | 12000 | 1.3 | 9360 | 10530 | 11700 | 12870 | 14040 | 15210 |
| SLZK150W | 15000 | 1.69 | 12168 | 13689 | 15210 | 16731 | 18252 | 19773 |
| SLZK180W | 18000 | 2.08 | 14976 | 16848 | 18720 | 20592 | 22464 | 24336 |
| SLZK230W | 23000 | 2.56 | 18432 | 20736 | 23040 | 25344 | 27648 | 29952 |
| SLZK270W | 27000 | 3.04 | 21888 | 24624 | 27360 | 30096 | 32832 | 35568 |
| SLZK320W | 32000 | 3.61 | 25992 | 29241 | 32490 | 35739 | 38988 | 42237 |
| SLZK370W | 37000 | 4.18 | 30096 | 33858 | 37620 | 41382 | 45144 | 48906 |
| SLZK430W | 43000 | 4.75 | 34200 | 38475 | 42750 | 47025 | 51300 | 55575 |
| SLZK500W | 50000 | 5.5 | 39600 | 44550 | 49500 | 54450 | 59400 | 64350 |
| SLZK550W | 55000 | 6.16 | 44352 | 49896 | 55440 | 60984 | 66528 | 72072 |
| SLZK630W | 63000 | 7 | 50400 | 56700 | 63000 | 69300 | 75600 | 81900 |
| SLZK700W | 70000 | 7.84 | 56448 | 63504 | 70560 | 77616 | 84672 | 91728 |
| SLZK760W | 76000 | 8.5 | 61200 | 68850 | 76500 | 84150 | 91800 | 99450 |
| SLZK850W | 85000 | 9.52 | 68544 | 77112 | 85680 | 94248 | 102816 | 111384 |
| SLZK930W | 93000 | 10.36 | 74592 | 83916 | 93240 | 102564 | 111888 | 121212 |
| SLZK1000W | 100000 | 11.47 | 82584 | 92907 | 103230 | 113553 | 123876 | 134199 |
| SLZK1100W | 110000 | 12.58 | 90576 | 101898 | 113220 | 124542 | 135864 | 147186 |
Note: 1. It is recommended to add a water baffle if the wind speed exceeds 2.75m/s.
Unit quick selection table (cooling capacity of coil section under return air condition)
| Model | Nominal air volume m³/h | 4 rows | 6 rows | 8 rows | |||
| Cooling capacity | Water volume | Cooling capacity | Water volume | Cooling capacity | Water volume | ||
| kW | m³/h | kW | m³/h | kW | m³/h | ||
| SLZK015W | 1500 | 8.2 | 1.4 | 10.9 | 1.87 | 13.2 | 2.27 |
| SLZK018W | 1800 | 10.2 | 1.8 | 13.6 | 2.34 | 16.5 | 2.84 |
| SLZK022W | 2200 | 12.6 | 2.2 | 16.4 | 2.82 | 19.8 | 3.41 |
| SLZK032W | 3200 | 17.8 | 3.1 | 23.8 | 4.09 | 28.8 | 4.95 |
| SLZK038W | 3800 | 21.5 | 3.7 | 28.6 | 4.92 | 34.6 | 5.95 |
| SLZK050W | 5000 | 28.7 | 4.9 | 38.1 | 6.55 | 46.2 | 7.95 |
| SLZK063W | 6300 | 35.8 | 6.2 | 47.8 | 8.22 | 57.5 | 9.89 |
| SLZK072W | 7200 | 41.1 | 7.1 | 54.6 | 9.39 | 66.1 | 11.37 |
| SLZK095W | 9500 | 53.3 | 9.2 | 70.8 | 12.18 | 85.6 | 14.72 |
| SLZK120W | 12000 | 66.7 | 11.5 | 88.6 | 15.24 | 107.1 | 18.42 |
| SLZK150W | 15000 | 86.6 | 14.9 | 115.3 | 19.83 | 138.6 | 23.84 |
| SLZK180W | 18000 | 106.5 | 18.3 | 141.8 | 24.39 | 170.3 | 29.29 |
| SLZK230W | 23000 | 131.2 | 22.6 | 172.9 | 29.74 | 210.5 | 36.21 |
| SLZK270W | 27000 | 155.8 | 26.8 | 206.8 | 35.57 | 248.6 | 42.76 |
| SLZK320W | 32000 | 185.1 | 31.8 | 245.2 | 42.17 | 296.5 | 51.00 |
| SLZK370W | 37000 | 214.2 | 36.8 | 285.1 | 49.04 | 341.8 | 58.79 |
| SLZK430W | 43000 | 243.3 | 41.8 | 323.6 | 55.66 | 385.6 | 66.32 |
| SLZK500W | 50000 | 281.5 | 48.4 | 374.5 | 64.41 | 450.3 | 77.45 |
| SLZK550W | 55000 | 315.7 | 54.3 | 419.3 | 72.12 | 500.4 | 86.07 |
| SLZK630W | 63000 | 358.6 | 61.7 | 476.5 | 81.96 | 560.4 | 96.39 |
| SLZK700W | 70000 | 400.5 | 68.9 | 534.1 | 91.87 | 640.5 | 110.17 |
| SLZK760W | 76000 | 432.6 | 74.4 | 578.2 | 99.45 | 690.5 | 118.77 |
| SLZK850W | 85000 | 482.5 | 83.0 | 645.8 | 111.08 | 765.8 | 131.72 |
| SLZK930W | 93000 | 520.6 | 89.5 | 702.3 | 120.80 | 830.5 | 142.85 |
| SLZK1000W | 100000 | 576.1 | 99.1 | 778.4 | 133.88 | 940.8 | 161.82 |
| SLZK1100W | 110000 | 630.6 | 108.5 | 850.6 | 146.30 | 970.5 | 166.93 |
Note:
1. The inlet temperature of chilled water is 7°C, and the outlet temperature is 12°C;
2. Return air condition: inlet air dry bulb temperature 27℃, wet bulb temperature 19.5℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.