TurnKey Solution Hydrophilic Fin Copper Tubes Air Dry Crypto Mining Cooler
Hydrophilic Fin Copper Tubes Crypto Mining Cooling Air Dry Coolers
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Benefits of Immersion Cooling:
- Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
- Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
- Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.
Why choose us:
|
Professional system integration: Customized size Thermodynamic calculations Authoritative seismic design Integrated wet curtain celdek7090 |
Frame: Galvanized sheet sprayed (RAI 7035) Hot dip galvanized sheet Stainless steel plate Galvanized sheet |
AC-EC fan: Protection grade ip55 Low energy consumption Inverter control High temperature resistant fan Explosion-proof fan |
Various diameter fans are available: 800, 1~14 psc 910, 1~18 psc 1250, 1~8 psc 1800, 1~7 psc |
|
Pipe: Copper Copper nickel alloy Stainless steel Titanium |
Fin: Epoxy coating Aluminum Copper: Tinned copper foil Blygold coating Stainless steel Titanium |
Overhaul and cleaning: Easy to clean Optional access door or hinged fan panel Fin form for easy cleaning Robust material with high mechanical strength Easy to maintain |
Different connection options: Flange connection Threaded connection Welding |
Technical parameter of Radiators
Dry cooler D3 series parameter(fin space 2.1mm)
| Type |
D3-042- 1X800 |
D3-046- 1X800 |
D3-051- 1X800 |
D3-087- 2X800 |
D3-094- 2X800 |
D3-103- 2X800 |
D3-125- 3X800 |
D3-146- 3X800 |
D3-153- 3X800 |
D3-175- 4X800 |
D3-188- 4X800 |
||||||
| Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | KW | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | |
| outlet | 40℃ | ||||||||||||||||
| 20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||||
| outlet | 40℃ | ||||||||||||||||
| Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||||
| Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||||
| Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||||
| Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||||
| A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||||
| Fan | No X φ |
1x1 x800 |
1x1 x800 |
1x1 x800 |
1x2 x800 |
1x2 x800 |
1x2 x800 |
1x3 x800 |
1x3 x800 |
1x3 x800 |
2x2 x800 |
2x2 x800 |
|||||
| Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||||
| 10m | |||||||||||||||||
| Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||||
| W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||||
| H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||||
| A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||||
| B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
| B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
| B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||||
| B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
| X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||||
| Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
| Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
| Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 |
|||||
Recently shipped photos:
![]() |
![]() |
![]() |
![]() |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.