Immersion Cooling Copper Tube Aluminum Fin Air Dry Coolers

Price Negotiable
Price: 505~31005 USD/Unit
MOQ: 1
Delivery Time: 35~40days
Brand: Shenglin
Product Description

Immersion Cooling Copper Tube Aluminum Fin Fluid Air Dry Coolers

 

Why immerse?

 

  1. Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
  2. Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
  3. Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.

 

Dry fluid cooler features:

Air discharge direction
Performance ranges

Cooling capacity: from 5 to 649 kw

Air volume: from 2828 to 263503 m3/h

Sound pressure level: from 31 to 69 dB A(10m)

Dry coolers:customized on demand

High efficiency heat exchanger

Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan.

Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition).

Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany

Fan

Only choose low specific energy consumption fans.

Fan nozzle designs for maximum air flow and air throw.

Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting.

Motor: protection class IP 54 and insulation class F.

Voltage:400V/3N/50Hz

Air separator for each fan.

Testing Heat exchangers are supplied clean and tested at a pressure of 30 bars
Options

Coil design refrigerant: water, oil, glycol.

Multiple circuits.

Sub-cooling circuits.

Stainless steel or aluminum casing.

Coated aluminum or copper fins.

Explosion ploof motor.

Customized fin spacing.


Dry fluid cooler technical parameter

Dry cooler D1 series parameter(fin space 2.1mm)

Type

D1-166-

4x630

D1-211-

6x630

D1-247-

6x630

D1-286-

8x630

D1-334-

8x630

D1-360-

10x630

D1-415-

10x630

D1-502-

12x630

D1-565-

14x630

D1-649-

16x630

Capacity Water 35℃ outdoor temp. Inlet 45℃, KW 165.92 211.36 247.3 286.15 334.49 359.72 415.31 502.25 565.18 649.48
outlet 40℃ Y 134.59 176.00 200.45 238.3 270.889 298.57 335.225 405.20 459.3 527.59
20% Glycol Inlet 45℃ 161.32 205.08 240.46 280.05 327.72 351.3 406.48 493.40 554.21 638.44
outlet 40℃ Y 130.96 170.87 195.07 233.18 265.64 291.81 328.48 398.45 450.87 519.13
Medium Water flow M3/h 29.00 37 43 50 58 63 72 88 98 113
Pressure drop kPa 50 70 47 97 95 92 70 97 96 95
Air flow M3/h 67455 109723 101185 146293 134908 179502 164442 197326 230584 263503
Y 51265 83661 76900 111544 102528 136437 124680 149612 174710 199665
Fan motor Phase 3 3 3 3 3 3 3 3 3 3
W 1100 16500 16500 22000 22000 27500 27500 33000 38500 44000
Y 700 10500 10500 14000 14000 17500 17500 21000 24500 28000
A 20.4 30.6 30.6 40.8 40.8 51.00 51.00 61.20 71.40 81.60
Y 12.00 18.00 18.00 24.00 24.00 30.00 30.00 36.00 42.00 48.00
Fan No X φ

2X2

X630

2x3

x630

2x3

x630

2x4

x630

2x4

x630

2x5

x630

2x5

x630

2x6

x630

2x7

x630

2x8

x630

Sound pressure level dB(A) 64 66 66 67 67 68 68 68 69 69
Y 10m 57 59 59 60 60 61 61 61 62 62
Dimension L mm 2930 4230 4230 5530 5530 6830 6830 8130 9430 10730
W mm 2100 2100 2100 2100 2100 2100 2100 2100 2100 2100
H mm 1070 1070 1070 1070 1070 1120 1120 1120 1120 1120
A mm -- -- -- -- -- -- -- -- -- --
B mm 1340 1340 1340 1340 1340 1340 1340 1340 1340 1340
C mm 1300 1300 1300 1300 1300 1300 1300 1300 1300 1300
D mm 640 640 640 640 640 640 640 640 640 640
Inlet φ mm 3” 3” 3” DN100 DN100 DN100 DN125 DN125

2X

DN125

2X

DN125

Inlet φ mm 3” 3” 3” DN100 DN100 DN100 DN125 DN125

2X

DN125

2X

DN125

Product weight(empty) kg 658 689 760 1105 1270 1320 1420 1584 1848 2112

Shenglin dry fluid cooler selection software example:


Packing:

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shanghai Shenglin M&E Technology Co., Ltd.
Location Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Contact Person Jason

Request A Quote

Please check your email address.
Your message must be at least 20 characters.