Immersion Cooling Copper Tube Aluminum Fin Air Dry Coolers
Immersion Cooling Copper Tube Aluminum Fin Fluid Air Dry Coolers
Why immerse?
- Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
- Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
- Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.
Dry fluid cooler features:
| Air discharge direction | ![]() |
| Performance ranges |
Cooling capacity: from 5 to 649 kw Air volume: from 2828 to 263503 m3/h Sound pressure level: from 31 to 69 dB A(10m) Dry coolers:customized on demand |
| High efficiency heat exchanger |
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
| Fan |
Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
| Testing | Heat exchangers are supplied clean and tested at a pressure of 30 bars |
| Options |
Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing. |
Dry fluid cooler technical parameter
Dry cooler D1 series parameter(fin space 2.1mm)
| Type |
D1-166- 4x630 |
D1-211- 6x630 |
D1-247- 6x630 |
D1-286- 8x630 |
D1-334- 8x630 |
D1-360- 10x630 |
D1-415- 10x630 |
D1-502- 12x630 |
D1-565- 14x630 |
D1-649- 16x630 |
||||||
| Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | △ | KW | 165.92 | 211.36 | 247.3 | 286.15 | 334.49 | 359.72 | 415.31 | 502.25 | 565.18 | 649.48 |
| outlet | 40℃ | Y | 134.59 | 176.00 | 200.45 | 238.3 | 270.889 | 298.57 | 335.225 | 405.20 | 459.3 | 527.59 | ||||
| 20% Glycol | Inlet | 45℃ | △ | 161.32 | 205.08 | 240.46 | 280.05 | 327.72 | 351.3 | 406.48 | 493.40 | 554.21 | 638.44 | |||
| outlet | 40℃ | Y | 130.96 | 170.87 | 195.07 | 233.18 | 265.64 | 291.81 | 328.48 | 398.45 | 450.87 | 519.13 | ||||
| Medium | Water flow | M3/h | 29.00 | 37 | 43 | 50 | 58 | 63 | 72 | 88 | 98 | 113 | ||||
| Pressure drop | kPa | 50 | 70 | 47 | 97 | 95 | 92 | 70 | 97 | 96 | 95 | |||||
| Air flow | △ | M3/h | 67455 | 109723 | 101185 | 146293 | 134908 | 179502 | 164442 | 197326 | 230584 | 263503 | ||||
| Y | 51265 | 83661 | 76900 | 111544 | 102528 | 136437 | 124680 | 149612 | 174710 | 199665 | ||||||
| Fan motor | Phase | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | 3 | |||||
| △ | W | 1100 | 16500 | 16500 | 22000 | 22000 | 27500 | 27500 | 33000 | 38500 | 44000 | |||||
| Y | 700 | 10500 | 10500 | 14000 | 14000 | 17500 | 17500 | 21000 | 24500 | 28000 | ||||||
| △ | A | 20.4 | 30.6 | 30.6 | 40.8 | 40.8 | 51.00 | 51.00 | 61.20 | 71.40 | 81.60 | |||||
| Y | 12.00 | 18.00 | 18.00 | 24.00 | 24.00 | 30.00 | 30.00 | 36.00 | 42.00 | 48.00 | ||||||
| Fan | No X φ |
2X2 X630 |
2x3 x630 |
2x3 x630 |
2x4 x630 |
2x4 x630 |
2x5 x630 |
2x5 x630 |
2x6 x630 |
2x7 x630 |
2x8 x630 |
|||||
| Sound pressure level | △ | dB(A) | 64 | 66 | 66 | 67 | 67 | 68 | 68 | 68 | 69 | 69 | ||||
| Y | 10m | 57 | 59 | 59 | 60 | 60 | 61 | 61 | 61 | 62 | 62 | |||||
| Dimension | L | mm | 2930 | 4230 | 4230 | 5530 | 5530 | 6830 | 6830 | 8130 | 9430 | 10730 | ||||
| W | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | |||||
| H | mm | 1070 | 1070 | 1070 | 1070 | 1070 | 1120 | 1120 | 1120 | 1120 | 1120 | |||||
| A | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
| B | mm | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 | |||||
| C | mm | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | 1300 | |||||
| D | mm | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 | |||||
| Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 |
2X DN125 |
2X DN125 |
|||||
| Inlet φ | mm | 3” | 3” | 3” | DN100 | DN100 | DN100 | DN125 | DN125 |
2X DN125 |
2X DN125 |
|||||
| Product weight(empty) | kg | 658 | 689 | 760 | 1105 | 1270 | 1320 | 1420 | 1584 | 1848 | 2112 | |||||