Mineral Oil Immersion Aluminum Fin Dry Fluid Cooler Chiller
Mineral Oil Immersion Cooling Copper Tube Aluminum Fin Air Dry Coolers
Why immerse?
- Silent Operations - Whether it’s single or two-phase immersion cooling, liquid cooling keeps your hardware submerged in a dielectric fluid of some type. More importantly, that will eliminates the noisy fans, which should be running throughout day and night in condition of air-based cooling and consume roughly 25-30% in additional power required to keep compute equipment on-line.
- Reduced PUE - Power usage effectiveness (PUE) is the ratio of a data center’s total facility energy to its total IT equipment (ITE) energy.Legacy or underside air-cooled techniques can struggle to maintain in the 1.8 to 2.4 range. Modern, purpose-built data centers have achieved significant PUE reductions using air-cooled chillers with closed-loop systems, often hitting a PUE of 1.3-1.5.With immersion cooling, PUE consistently stays under 1.3, drastically reducing a facility’s energy load.
- Cost Savings - Cooling accounts for a large part of operating expenses. A facility that houses thousands of servers is also expected to run 24/7, 365 days a year. In traditional air cooling, a large number of fans, HVAC and CRAC systems contribute a lot to the electricity bill. However, when servers are submerged in thermally conductive cooling solutions, electricity usage is reduced by more than 95%, which no one can refuse.
Application:
- Data center air conditioning system.
- Cryptocurrency cooling system.
Air dry cooler features:
| Air discharge direction | ![]() |
| Performance ranges |
Cooling capacity: from 5 to 649 kw Air volume: from 2828 to 263503 m3/h Sound pressure level: from 31 to 69 dB A(10m) Dry coolers:customized on demand |
| High efficiency heat exchanger |
Capacity designs for maximizing the heat transfer relative to the energy consumption of the fan. Tube and tube coupling design for low pressure drop in the coil on the media sides(maximum 100KPa at water designing condition). Our thermodynamic and aerodynamic designing software is long year tested and proved in Germany |
| Fan |
Only choose low specific energy consumption fans. Fan nozzle designs for maximum air flow and air throw. Our fans from the world`s leading manufacturer are practically proved to be reliable in operation and long lasting. Motor: protection class IP 54 and insulation class F. Voltage:400V/3N/50Hz Air separator for each fan. |
| Testing | Heat exchangers are supplied clean and tested at a pressure of 30 bars |
| Options |
Coil design refrigerant: water, oil, glycol. Multiple circuits. Sub-cooling circuits. Stainless steel or aluminum casing. Coated aluminum or copper fins. Explosion ploof motor. Customized fin spacing. |
Dry fluid cooler technical parameter
FLAT SERIES SINGLE ROW FANS
| H*VS*91 H*VS*125 |
Van Dim mm |
* | H*VS191 H*VS1125 | H*VS291 H*VS212 | H*VS391 H*VS3125 | H*VS491 H*VS4125 | H*VS591 H*VS5125 | H*VS691 H*VS6125 | H*VS791 H*VS7125 | H*VS891 H*VS8125 | H*VS991 H*VS9125 | H*VS1091 H*VS10125 |
| Rated Capacities (kW) Heat Exchange Surface (㎡) | ||||||||||||
| Fluid Coolers | 910 | D | 69kW-1050kW 171㎡-4711㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||||
| 1250 | 182kW-2056kW 481㎡-8546㎡ (Water/Ta25℃/Tin40℃/Tout35℃) | |||||||||||
| Freon Condensers | 910 | F | 86kW-1167kW 171㎡-4711㎡ (R404A/Ta35℃/Tk50℃) | |||||||||
| 1250 | 212kW-2340kW 481㎡-8546㎡ (R404A/Ta35℃/Tk50℃) | |||||||||||
| Ammonia Condensers | 910 | A | 93kW-1234kW 203㎡-6027㎡ (NH3/Ta35℃/Tk50℃) | |||||||||
| 1250 | 201kW-2377kW 502㎡-10046㎡ (NH3/Ta35℃/Tk50℃) | |||||||||||
| Gas Coolers | 910 | G | 81kW-1534kW 259㎡-4711㎡ (CO2/Tair32℃/Tin113℃/P94Bar/Tout34℃) | |||||||||
| Oil Coolers | 910 | O | 65kW-2126kW 171㎡-4711㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||||
| 1250 | 176kW-3548kW 481㎡-8546㎡ (OIL ISO VG 46/Ta35℃/Tin85℃/Tout60℃) | |||||||||||
| Fan Model | 910 | EC | W3G910KU2503 (2.55kW) or FN091-ZIQ.GL.V5P1 (3.2kW) | |||||||||
| 910 | AC | W6D910GB0101 (2.02kW) or FN091-SDS.6N.V7P2 (1.85kW) | ||||||||||
| 1250 | EC | 160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L | ||||||||||
| 1250 | AC | 160M2-8P-5.5kW/720RPM/1250_5-5_LP_39°_PPG_9W2L | ||||||||||
| No of Fans | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | ||
| Overall Dimensions | 910 | Lenth | 1530 | 2730 | 3930 | 5130 | 6330 | 7530 | 8730 | 9930 | 11130 | 12330 |
| Width | 2000 | |||||||||||
| Width+Pad | 2260 | |||||||||||
| Height | 2260 | |||||||||||
| 1250 | Lenth | 1930 | 3530 | 5130 | 6730 | 8330 | 9930 | 11530 | 13130 | 14730 | 16330 | |
| Width | 2000 | |||||||||||
| Width+Pad | 2260 | |||||||||||
| Height | 2360 | |||||||||||