IFM Pressure sensor with display PN2071 PN-250-SER14-MFRKG/US/ in stock
Price:
USD
MOQ:
1PC
Delivery Time:
4-6weeks
Brand:
IFM
Product Description
IFM Pressure sensor with display PN2071 PN-250-SER14-MFRKG/US/ in stock
- Two switching outputs, one of them programmable as IO-Link and one as analogue output
- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Measuring range 0...250 bar 0...3625 psi 0...25 MPa Process connection threaded connection G 1/4 internal thread (DIN EN ISO 1179-2) Application
Special feature Gold-plated contacts Measuring element metallic thin film cell Application for industrial applications Media liquids and gases Medium temperature[°C] -25...80 Min. bursting pressure 1200 bar 17400 psi 120 MPa Pressure rating 500 bar 7250 psi 50 MPa Vacuum resistance -1000 mbar -0.1 MPa Type of pressure relative pressure Electrical data
Operating voltage[V] 18...30 DC; (to SELV/PELV) Current consumption[mA] < 35 Min. insulation resistance[MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time[s] 0.3 Integrated watchdog yes Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Outputs
Total number of outputs 2 Output signal switching signal; analogue signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / normally closed; (parameterisable) Max. voltage drop switching output DC[V] 2 Permanent current rating of switching output DC[mA] 250 Switching frequency DC[Hz] < 500 Number of analogue outputs 1 Analogue current output[mA] 4...20; (scalable 1:5) Max. load[Ω] 500 Analogue voltage output[V] 0...10; (scalable 1:5) Min. load resistance[Ω] 2000 Short-circuit protection yes Type of short-circuit protection pulsed Overload protection yes Measuring/setting range
Measuring range 0...250 bar 0...3625 psi 0...25 MPa Analogue start point 0...200 bar 0...2900 psi 0...20 MPa Analogue end point 50...250 bar 725...3625 psi 5...25 MPa Factory setting / CMPT = 2 Set point SP 1.5...250 bar 25...3625 psi 0.15...25 MPa Reset point rP 0.5...249 bar 10...3610 psi 0.05...24.9 MPa Min. difference between SP and rP 1.5 bar 15 psi 0.15 MPa In steps of 0.5 bar 5 psi 0.05 MPa Status_B High Resolution / CMPT = 3 Set point SP 1.6...250 bar 23...3626 psi 0.16...25 MPa Reset point rP 0.5...249 bar 8...3611 psi 0.05...24.9 MPa Min. difference between SP and rP 1.1 bar 15 psi 0.11 MPa In steps of 0.1 bar 1 psi 0.01 MPa Accuracy / deviations
Switch point accuracy[% of the span] < ± 0,4; (Turn down 1:1) Repeatability[% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation[% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting) Hysteresis deviation[% of the span] < ± 0,1; (Turn down 1:1) Long-term stability[% of the span] < ± 0,05; (Turn down 1:1; per 6 months) Temperature coefficient zero point[% of the span / 10 K] 0,2; (-25...80 °C) Temperature coefficient span[% of the span / 10 K] 0,2; (-25...80 °C) Notes on the accuracy / deviation switch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1% Response times
Response time[ms] < 1.5 Delay time programmable dS, dr[s] 0...50 Damping process value dAP[s] 0...4 Damping for the analogue output dAA[s] 0...4 Max. response time analogue output[ms] 3 Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output Interfaces
Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 SIO mode yes Required master port type A; (when pin 2 not connected: B) Supported DeviceIDs Type of operation DeviceID Factory setting / CMPT = 2 460 Status_B High Resolution / CMPT = 3 639 Note For further information please see the IODD PDF file under "Downloads" Factory setting / CMPT = 2 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis Min. process cycle time[ms] 2.3 IO-Link resolution pressure[bar] 0.1 IO-Link process data (cyclical) function bit length pressure 14 binary switching information 2 IO-Link functions (acyclical) application specific tag Status_B High Resolution / CMPT = 3 Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) Min. process cycle time[ms] 3 IO-Link resolution pressure[bar] 0.1 IO-Link process data (cyclical) function bit length pressure 16 device status 4 binary switching information 2 IO-Link functions (acyclical) application specific tag Operating conditions
Ambient temperature[°C] -25...80 Storage temperature[°C] -40...100 Protection IP 65; IP 67 -
•We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
-
•It will take 3 to 7days to reach in your hands.China Post delivery schedule will be in 20-45 days. If you can't wait, please choose other express.
Our Advantage:
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
GREAT SYSTEM INDUSTRY CO. LTD
Location
10A, SEAVIEW PLAZA, TAIZI ROAD, NANSHAN DISTRICT, SHENZHEN, CHINA
Contact Person
Roc