IFM Pressure sensor with display PN7099 PN-1-1BRER14-QFRKG/US/ /V in stock
Price:
USD
MOQ:
1PC
Delivery Time:
4-6weeks
Brand:
IFM
Product Description
IFM Pressure sensor with display PN7099 PN-1-1BRER14-QFRKG/US/ /V in stock
- Two switching outputs, one of them programmable as IO-Link and one as analogue output
- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
-
Product characteristics
Number of inputs and outputs Number of analogue outputs: 1 Measuring range -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa Process connection threaded connection Aseptoflex external thread Aseptoflex Application
Special feature Gold-plated contacts Application flush mountable for the food and beverage industry Media viscous media and liquids with suspended particles; liquids and gases Medium temperature[°C] -25...125; (145 max. 1h) Min. bursting pressure 30000 mbar 12000 inH2O 3000 kPa Pressure rating 6000 mbar 2400 inH2O 600 kPa Type of pressure relative pressure No dead space yes Electrical data
Operating voltage[V] 14...30 DC Min. insulation resistance[MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Measuring principle hydrostatic Inputs / outputs
Number of inputs and outputs Number of analogue outputs: 1 Outputs
Total number of outputs 1 Output signal analogue signal Number of analogue outputs 1 Analogue current output[mA] 4...20 Max. load[Ω] 550; (Ub = 24 V; (Ub - 13 V) / 20 mA) Overload protection yes Measuring/setting range
Measuring range -0.0125...0.25 bar -12.5...250 mbar -5...100.4 inH2O -1.25...25 kPa Analogue start point -12.5...100 mbar -5...40.2 inH2O -1.25...10 kPa Analogue end point 50...250 mbar 20.2...100.4 inH2O 5...25 kPa In steps of 0.5 mbar 0.2 inH2O 0.05 kPa Factory setting ASP = 0.0 mbar AEP = 250.0 mbar Accuracy / deviations
Repeatability[% of the span] < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) Characteristics deviation[% of the span] < ± 0,6; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) Linearity deviation[% of the span] < ± 0,5; (Turn down 1:1) Hysteresis deviation[% of the span] < ± 0,1; (Turn down 1:1) Long-term stability[% of the span] < ± 0,1; (Turn down 1:1; per year) Temperature coefficient zero point[% of the span / 10 K] < ± 0,1; (0...80 °C) Temperature coefficient span[% of the span / 10 K] < ± 0,4; (0...80 °C) Response times
Max. response time analogue output[ms] 3 Software / programming
Parameter setting options zero point; span Interfaces
Communication interface EPS Operating conditions
Ambient temperature[°C] -25...80 Storage temperature[°C] -40...100 Protection IP 67 Product characteristics
Number of inputs and outputs Number of digital outputs: 2 Measuring range -1...1 bar -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa Process connection threaded connection G 1/4 internal thread Application
Special feature Gold-plated contacts Measuring element ceramic-capacitive pressure measuring cell Application for industrial applications Media liquids and gases Medium temperature[°C] -25...80 Min. bursting pressure 30000 mbar 450 psi 880 inHg 3000 kPa Pressure rating 10000 mbar 145 psi 290 inHg 1000 kPa Vacuum resistance -1000 mbar -0.1 MPa Type of pressure relative pressure; vacuum Electrical data
Operating voltage[V] 18...30 DC; (to SELV/PELV) Current consumption[mA] < 35 Min. insulation resistance[MΩ] 100; (500 V DC) Protection class III Reverse polarity protection yes Power-on delay time[s] < 0.3 Integrated watchdog yes Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2 Outputs
Total number of outputs 2 Output signal switching signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / normally closed; (parameterisable) Max. voltage drop switching output DC[V] 2.5 Permanent current rating of switching output DC[mA] 150; (200 (...60 °C) 250 (...40 °C)) Switching frequency DC[Hz] < 170 Short-circuit protection yes Type of short-circuit protection pulsed Overload protection yes Measuring/setting range
Measuring range -1...1 bar -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa Factory setting / CMPT = 2 Set point SP -980...1000 mbar -14.3...14.5 psi -29...29.6 inHg -98...100 kPa Reset point rP -990...990 mbar -14.4...14.4 psi -29.4...29.2 inHg -99...99 kPa Min. difference between SP and rP 10 mbar 0.2 psi 0.4 inHg 1 kPa In steps of 10 mbar 0.1 psi 0.2 inHg 0.1 kPa Status_B High Resolution / CMPT = 3 Set point SP -983...1000 mbar -14.3...14.5 psi -29...29.5 inHg -98...100 kPa Reset point rP -993...990 mbar -14.4...14.4 psi -29.3...29.2 inHg -99...99 kPa Min. difference between SP and rP 10 mbar 0.2 psi 0.3 inHg 1 kPa In steps of 1 mbar 0.1 psi 0.1 inHg 0.1 kPa Accuracy / deviations
Switch point accuracy[% of the span] < ± 0,5 Repeatability[% of the span] < ± 0,1; (with temperature fluctuations < 10 K) Characteristics deviation[% of the span] < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) Hysteresis deviation[% of the span] < ± 0,25 Long-term stability[% of the span] < ± 0,05; (per 6 months) Temperature coefficient zero point[% of the span / 10 K] < ± 0,2; (-25...80 °C) Temperature coefficient span[% of the span / 10 K] < ± 0,2; (-25...80 °C) Response times
Response time[ms] < 3 Delay time programmable dS, dr[s] 0...50 Software / programming
Parameter setting options hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit Interfaces
Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 SIO mode yes Required master port type A; (when pin 2 not connected: B) Process data analogue 1 Process data binary 2 Supported DeviceIDs Type of operation DeviceID Factory setting / CMPT = 2 406 PN7009 314 Status_B High Resolution / CMPT = 3 604 Note For further information please see the IODD PDF file under "Downloads" Factory setting / CMPT = 2 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis Min. process cycle time[ms] 2.3 IO-Link resolution pressure 1 mbar 0.0001 MPa IO-Link process data (cyclical) function bit length pressure 14 binary switching information 2 IO-Link functions (acyclical) application specific tag Status_B High Resolution / CMPT = 3 Profiles Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) Min. process cycle time[ms] 3 IO-Link resolution pressure 1 mbar 0.0001 MPa IO-Link process data (cyclical) function bit length pressure 16 device status 4 binary switching information 2 IO-Link functions (acyclical) application specific tag Operating conditions
Ambient temperature[°C] -25...80 Storage temperature[°C] -40...100 Protection IP 65; IP 67

-
•It will take 3 to 7days to reach in your hands.China Post delivery schedule will be in 20-45 days. If you can't wait, please choose other express.
Our Advantage:
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
GREAT SYSTEM INDUSTRY CO. LTD
Location
10A, SEAVIEW PLAZA, TAIZI ROAD, NANSHAN DISTRICT, SHENZHEN, CHINA
Contact Person
Roc