Teledyne B71875 Insta Trace Oxygen Analyzer Sensor - 0-10 ppm Range with Rapid Recovery Technology for Inert Gas Streams
Price:
negotiable
MOQ:
1PC
Delivery Time:
on request
Brand:
Teledyne
Product Description
Product Overview
The B71875 Insta Trace Oxygen Analyzer from Teledyne Analytical Instruments is a specialized oxygen sensor designed for general purpose trace oxygen analysis applications. This advanced sensor features patented construction technology that enables rapid recovery to low PPM levels during initial installation.
Key Specifications
- Part Number: B71875 -INSTA TRACE
- Manufacturer: Teledyne (USA)
- Measurement Range: 0-10 ppm oxygen
- Application: Trace O2 analysis in inert gas and hydrocarbon streams
- Special Feature: Rapid recovery from hours to minutes during installation
Teledyne Oxygen Sensor Models Comparison
| Model | Part Number | Primary Application | Key Features |
|---|---|---|---|
| A-2C | C6689-A2C | Trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2) | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. |
| A-2CXL | B74033-A2CXL | Specially qualified for XL model analyzers (0-1 ppm range) | Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present. |
| A-5 | C6689-A5 | Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2 | 90% response time is 45 seconds. More tolerance to air exposure than A-3. |
| B-1 | C6689-B1 | General purpose percent oxygen analysis requiring fast response | 90% response in less than 7 seconds. May be used to spot check flue gas. |
| B-2C | C6689-B2C | General purpose trace O2 analysis for inert gas and hydrocarbon streams | Low range limit is 0-10 ppm. Suitable for CO2 free gas streams with H2, He, ethylene. |
| INSTA TRACE | B71875 | Trace O2 analysis in inert gas and hydrocarbon streams | Patented construction reduces recovery period from hours to minutes (0-10 ppm range) |
| B-3 | C6689-B3 | Percent O2 analysis balancing long life and fast response | May be used to spot check flue gas. 90% response time is 30 seconds. |
| C-3 | C6689-C3 | Percent O2 measurements requiring maximum cell life | 90% response time is 30 seconds. Expected life in air is 18 months. |
Quality Assurance & Service
- 100% original Teledyne product with complete quality assurance
- Multiple payment options: T/T, Western Union, PayPal (EUR, USD, RMB)
- Global shipping via DHL, UPS, FedEx, TNT and regional carriers
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
GREAT SYSTEM INDUSTRY CO. LTD
Location
10A, SEAVIEW PLAZA, TAIZI ROAD, NANSHAN DISTRICT, SHENZHEN, CHINA
Contact Person
Roc