Shenzhen Sino-Australia Refrigeration Equipment Co., Ltd.
                                                                                                           
Verified Supplier
23 Years
Since 2003
Menu
Machinery Refrigeration & Heat Exchange Equipment Refrigeration & Heat Exchange Parts

SF 102S AC12V Chiller Freezer Digital Temperature Controller For 1 HP Compressor

Price Negotiable
Price: negotiate
MOQ: 5 sets
Delivery Time: 4-6 weeks
Brand: SF
Product Description

SF-102S Digital Temperature Controller For Freezer,Chiller, Refrigeration System, Condensing Unit

Features of Function

* Mini-sized and integrated intelligent control and applicable to the compressor of one HP.
 
* Temperature Display/ Temperature Control/ Manual, automatic defrost by turning off /Light Control/Value Storing/ Self Testing /Parameter Locking.
 
Specifications
 
1. Output of the outside sealed transformer:AC12V(one transformer matched with one temp. controller)
2. Temperature sensor: NTC, Double sensors(for cold room temp.&defrost control),2m(L)
3. Range of temperature displayed : -45 ~ 45℃ ; Accuracy:±1℃
4. Range of set temperature: -45 ~ 45℃ ; Factory default :±1℃
5. Temperature of the operating environment: -10 ~ 60℃ ; Relative Humidity:20%~90%(Non-condensing)
6. Relay rated coil voltage:12VDC
7. Relay output contact capacity:  -Compressor relay: N.O. 30A/250VAC (applicable to 1 HP Compressor,if more connected to AC contactor)   -Light relay: N.O.30A/240VAC

Technical Parameters 

Parameter
Function
Set range
Default
E1
Lower setpoint limit
-45℃~Set temp.
-35℃
E2
Higher setpoint limit
Set temp.~45℃
20℃
E3
Temp.hysteresis
1~10℃
4℃
E4
Comp.start delay time
0~10Min
2Min
E5

 

Offset on room temp.
-5℃
0℃
E6 Offset on evap. temp. -5℃ 0℃
F1
Max.Defrost duration
1~60Min
20Min
F2
Defrost interval time
0~24Hr

 

6Hr
F3 Defrost termination temp. 0~20℃ 8℃
F4 Display during defrost 0=normal display 1= last value before defrost 0
C1 Temperature unit 0=℃  0

 

 

Notes for Installation
1. Sensor leads must be kept separately from main voltage wires in order to avoid high frequency noise induced. Separate the power supply of the loads from the power supply of the controller.
 
2. When installation the sensor shall be placed with the head upward and the wire downward; The evaporator sensor must be installed between the fins of the evaporator in the area, where probably the ice is the thickest.
 
3.In case of long-distance sensor installation from the controller, the sensor cable may be prolonged up to 100 m max. without any re-calibration.
 
4.The temperature controller can not be installed in the area with water drops.
 
Accessories for the temperature controller
 
1. One attached transformer and two relays
2. Two temperature sensors
3. One installation stand
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Sino-Australia Refrigeration Equipment Co., Ltd.
Location 6F Building No.2 Huamei Industry Zone,Jingnan Road,Buji Town,Longgang Disctrict,Shenzhen,China
Contact Person Jason

Request A Quote

Please check your email address.
Your message must be at least 20 characters.