4S1P 1280Wh Portable Backup Power Station 12.8V 100Ah LiFePO4 Li Ion Battery
Portable Energy Storage Station 12.8V 100Ah LiFePO4 Li-ion Battery , 1280Wh High Energy for Outdoor Power Supply
Production Description:
1. General
This product specification describes the technique requirements, test procedures and precaution notes of LiFePO4 battery pack AMT-ESS BATTERY-12.8V-100Ah, manufactured by Shenzhen AMT Technology Co., Ltd.
2. Battery’s Characteristics:
- Sturdy and pressure resistant steel envelope
- Short time to take full charge
- High capacity and high energy density
- Excellent cycle life
- Excellent high and low temperature performance
- Steady output voltage
- Low self-discharge
- Double safety protection
- With outstanding high level of vibrations and shocks
- Having iron and plastic shells for choice
- Environmentally-friendly
3. Key Parameter for cell and battery pack
| Item | Parameter | Remark | |
| Cell | Type | LiFePO4 Battery | |
| Cell Model | LF48174133-100Ah | RP | |
| Nominal Capacity | 100Ah | Discharge : 0.2C | |
| Cut-off Voltage:2.5V | |||
| Minimum Capacity | 98Ah | Discharge : 0.2C | |
| Cut-off Voltage: 2.5V | |||
| Nominal voltage | 3.2V | ||
| Internal Impedance | ≤0.45mΩ | ||
| Dimension | Max.L173.9±0.5XW132.2±0.5H48±0.5mm | ||
| Weight | Approx.2.2kg | ||
|
Battery pack |
Pack Method | 4S1P | |
| Nominal Capacity | 100Ah | Discharge : 0.2C | |
| Cut-off Voltage:10V | |||
| Minimum Capacity | 98Ah | Discharge : 0.2C | |
| Cut-off Voltage: 10V | |||
| Nominal Voltage | 12.8V | ||
| Energy | 1280Wh | ||
| Charge Voltage | 14.6V | ||
| Discharge cut-off voltage | 10V | ||
| Charge Method | CC/CV | ||
| Standard Charge Current | 10A | ||
| Max. Charge Current | 30A | ||
| Standard Discharge Current | 20A | ||
| Max. Continues Discharge current | 100A | ||
| Cycle Life | 2000 times | 80% | |
| Internal Impedance | ≤30mΩ | ||
| Dimension | L521xW237.9xH217.3mm | Gray/Silver | |
| Weight | Approx.13.8kg | ||
| USB 2 Output | 5V 2.1A | ||
| Max USB QC3.0 Output | Max 18W | ||
| Type-C Output | Max 60W | ||
| 2*DC12V Output | Max 7A | ||
| DC Switch Output | Max 10A | ||
| AC Output | 110V/ 220V,60Hz/50Hz,Rated power 1000W | Peak power 2000W | |
| PV Input | Max 15~25V 150W |
Suggested Max 18V150W |
|
| Working Temperature Range | Charge: 0°C--45°C | ||
| Discharge: -20°C--60°C | |||
| Storage Temperature | -10°C--50°C | ||
4. The parameter for BMS
4. 1Table 1Technical Parameter
| No. | Item | Parameter | Remark |
| Technical Parameter for LY-MP091-A | |||
| 1 | Working Voltage Range | 8.8~26V | DC |
| 2 | Working Consumption | <500uA | @12.8V |
| 3 | Sleep Consumption | <100uA | @12.8V |
| 4 | WorkingTemperature Range | -20~80℃ |
|
| 5 | WorkingHumidity Range | 15%~90% | No condensation |
| 6 | Overall VoltageTestAccuracy | <1%FSR | |
| 7 | TemperatureTest Range | -30~90℃ |
|
| 8 | TemperatureTestAccuracy | <±3℃ | |
| 9 | CurrentTestAccuracy | <1%FSR | |
| 10 | SOCEstimateAccuracy | <8% | |
| 11 | Max. Continuous Discharge Current | 100A | |
| 12 | Max. Continuous charge Current | 30A | |
| 13 | Communication Port | SMBus v1.1 | |
| Technical Parameter for LY-MP091-B | |||
| 1 | Working Voltage Range | 8~28V | |
| 2 | Sleep Consumption | <500uA | @12.8V |
| 3 | DC Output | USD 3 Output | 5V/2.1A |
| 4 | USB QC3.0 output | Max 18W | |
| 5 | Type-C | Max 60W | |
| 6 | 2*DC12V Output | Max 7A | |
| 7 | DC12V Switch | Max 10A | |
| 8 | Inverter Control Signal | ||
| 9 | Communication Port | 12C Communication Port | SMBus communicatewith BMS LY-MP091-A to gain battery information |
| 10 | Button | 2 Independent Button | DC12V, USB, AC, Control DC12V, USB andAC separately |
| 11 | Display | LCD Screen | Indication of batteryinformation |
| 12 | Working Temperature Range | -20~80℃ |
|
| 13 | Working Humidity Range | 15%~90% | No condensation |
4.2 Table 2 Protection Value
| Item | Trigger Condition | Standard Parameter | Remark |
| Over charge protection and recovery for cell | Over charge inspect voltage | 3.70V±10mV | |
| Over charge release voltage | 3.55V±10mV | ||
| Over discharge protection and recovery for cell | Over discharge inspect voltage | 2.5V±10mV | |
| Over discharge release voltage | 2.8V±10mV | ||
| Charge over current | Charge over current protect 1 | 25000mA±2A | |
| Charge over current protect 2 | 40000mA±2A | ||
| Discharge over current | Discharge over current protection 1 | 100000mA±2A | |
| Discharge over current protection 2 | 125000mA±2A | ||
| Short circuit | Load short circuit | Yes | |
| Charge over temperature | Charge over temperature protection | 55℃±2℃ | |
| Protection time delay | 5S | ||
| Charge high temperature recovery | 55℃±2℃ | ||
| Charge low temperature | Charge low-temperature protection | 0℃±2℃ | |
| Protection time delay | 5S | ||
| Charge low-temperature recovery | 5℃±2℃ | ||
| Discharge over temperature | Discharge over temperature protection | 60℃±2℃ | |
| Protection time delay | 5S | ||
| Discharge high temperature recovery | 55℃±2℃ | ||
| Discharge low temperature | Discharge low temperature protection | -20℃±2℃ |
|
| Protection time delay | 5S | ||
| Discharge low temperature recovery | -10℃±2℃ |
||
| Standard USB | Over current protection | 2.5A±0.2A | Recover in 10s afterload is disconnected |
| DC12V | Over current protection | 7A±0.5A | Recover in 10s afterload is disconnected |
| DC12V switch | Over current protection | 10A±0.5A | Recover in 10s afterload is disconnected |
| USB QC3.0 | Protection power | 18W±0.5W | Disconnect load andreconnect |
| Type-C | Over current protection | 4A±0.2A | Disconnect load and reconnect, output power shall be <60W |
5. Product Circuit diagram
6. Inverter Parameter
| Model | PS1000-1211 | PS1000-1222 | |
| Output | Rated power | 1000W | |
| Peak power | 2000W | ||
| AC voltage | 110V AC | 220V AC | |
| Output frequency | 60Hz±0.5Hz | 50Hz±0.5Hz | |
| Output Waveform | Pure sine wave(THD<3%) | ||
| Input | Battery voltage | 12V | |
| Battery voltage range | DC10~15V | ||
| DC current | 110A | ||
| Work efficiency | 90% | ||
| Battery input protetion | Fuse | 40A*4 | |
| Battery low voltage alarm | 11V±4% | ||
| Battery low voltage shutdown | 10V±4% | ||
| Battery with reverse protection | Blow off an internal fuse | ||
| Output protection | over temperature protection | Whenthe temperature of the temperature control point reaches 70℃±3℃, the output will be stopped, and the built-in buzzer will have 5 alarmsat an interval of 1 second (continuous mode). | |
| Overload protection | Whenthe load reaches 115% ~ 145%, the alarm indicates that after 10 seconds, the output is turned off, and the switch needs to be reset for recovery | ||
| Whenthe load reaches more than 145%, shut off the output for 2 seconds | |||
| Output short circuit protection | (self-recovery mode) turn off the output voltage, remove the load fault automatic recovery | ||
7. Packing drawing
8. Electrical Performance for cell
| Item | Test Condition | Specification |
| Open-Circuit Voltage | The open-circuit voltage shall be measured within 24hours after standard charge | ≥13.2V |
| Battery Capacity | The discharge time at 40A shall be measured after standard charge at 20±5℃ and rest 30mins | ≥100% |
| Cycle Life | The discharge time on standard discharge shall be measured after 2000 cycles of standard charge and discharge at 20±5℃ | ≥80% |
| Charge(capacity) retention | The discharge time at 40A shall be measured after standard charge and then storage at 20±5℃ for 28days | ≥80% |
| Temperature Characteristics | After standard charging at 20±5℃, laying the battery at 55℃ for 2hour, then discharge at 40A to 10V, record the discharge time | ≥80% |
| Temperature Characteristics | After standard charging at 20±5℃, laying the battery at -10℃ for 4hour, then discharge at 40A to 10V, record the discharge time | ≥60% |
9. Machanical Performance for cell
| Item | Test Condition | Specification |
| Crush Test | A battery is to be crushed between two flat surfaces. The force for the crushing is to be applied by a hydraulic ram with a 32mm diameter piston. The crushing is to be continued until a pressure reading of 17.2mmPa is reached on the hydraulic ram, applied force of 13kN. Once the maximum pressure has been obtained it is to be released. | No fire,No explosion |
| Drop Test | The battery has only two axes of symmetry in which case only two directions shall be tested. The battery is to be dropped from a height of 1 meter twice onto concrete ground. | No explosion, No fire, No smoke |
| Vibration | A full-charged battery is to be subjected to simple harmonic motion with an amplitude of 1.6mm total maximum excursion. The frequency is to be varied at the rate of 1 hertz per minute between 10 and 55 hertz. The cell shall be vibrated for 30 minutes per axis o XYZ axes. | No leakage, No Fire, No explosion |
10. Cell Safety Performance
| Item | Test Condition | Specification |
| Over charge | At 20±5℃, charging battery with constant current 1C to voltage 4V, then with constant voltage 4V till current decline to 0. | No explosion, No fire |
| Over discharge | At 20±5℃, according to the requirement of the standard of discharge after discharge to termination voltage, 30 m Ω external load discharge within 24 hours. | No explosion, No fire |
| Short-circuit | At 20±5℃, Standard charge, across the electrodes of the battery with a less than 50 m Ω wire connection, 6 hours | No explosion, No fire The temperature of the surface of the cell are lower than 150℃ |
| Heating | Battery is heated in a circulating air oven at a rate of 5±2℃ per mins to 130℃, an then placed 30 mins at 130℃ | No explosion, no fire |
11. Our Company
Shenzhen AMT Technology Co., Ltd, a professional manufacturer of LiFePO4 Lithium ion batteries. Our LiFePO4 Lithium ion batteries provide steady discharge & charge performance in a lighter volume, are applicable for different kinds of EV/PHEV/UPS/Storage energy/Starting power supply.Have passed ISO 9001, ISO 14000,UL1642/UN38.3/CB(IEC62133)/BIS/ROHS/CE certification, With our advanced equipments, we can provide customized product with high quality.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.