Shenzhen AMT Technology Co., Ltd.
                                                                                                           
Verified Supplier
13 Years
Since 2013
Menu

4S1P 1280Wh Portable Backup Power Station 12.8V 100Ah LiFePO4 Li Ion Battery

Price Negotiable
Price: Negotiate
MOQ: 100 pcs
Delivery Time: 3-4weeks for samples; 5~6 weeks for mass production.
Brand: ODM/OEM
Product Description

Portable Energy Storage Station 12.8V 100Ah LiFePO4 Li-ion Battery , 1280Wh High Energy for Outdoor Power Supply

Production Description:

 

1. General

This product specification describes the technique requirements, test procedures and precaution notes of LiFePO4 battery pack AMT-ESS BATTERY-12.8V-100Ah, manufactured by Shenzhen AMT Technology Co., Ltd.

 

2. Battery’s Characteristics:

  • Sturdy and pressure resistant steel envelope
  • Short time to take full charge
  • High capacity and high energy density
  • Excellent cycle life
  • Excellent high and low temperature performance
  • Steady output voltage
  • Low self-discharge
  • Double safety protection
  • With outstanding high level of vibrations and shocks
  •  Having iron and plastic shells for choice
  • Environmentally-friendly

3. Key Parameter for cell and battery pack

 

Item Parameter Remark
Cell Type LiFePO4 Battery  
Cell Model LF48174133-100Ah RP
Nominal Capacity 100Ah Discharge : 0.2C
Cut-off Voltage:2.5V
Minimum Capacity 98Ah Discharge : 0.2C
Cut-off Voltage: 2.5V
Nominal voltage 3.2V  
Internal Impedance ≤0.45mΩ  
Dimension Max.L173.9±0.5XW132.2±0.5H48±0.5mm  
Weight Approx.2.2kg  

Battery

pack

Pack Method 4S1P  
Nominal Capacity 100Ah Discharge : 0.2C
Cut-off Voltage:10V
Minimum Capacity 98Ah Discharge : 0.2C
Cut-off Voltage: 10V
Nominal Voltage 12.8V  
Energy 1280Wh  
Charge Voltage 14.6V  
Discharge cut-off voltage 10V  
Charge Method CC/CV  
Standard Charge Current 10A  
Max. Charge Current 30A  
Standard Discharge Current 20A  
Max. Continues Discharge current 100A  
Cycle Life 2000 times 80%
Internal Impedance ≤30mΩ  
Dimension L521xW237.9xH217.3mm Gray/Silver
Weight Approx.13.8kg  
USB 2 Output 5V 2.1A  
Max USB QC3.0 Output Max 18W  
Type-C Output Max 60W  
2*DC12V Output Max 7A  
DC Switch Output Max 10A  
AC Output 110V/ 220V,60Hz/50Hz,Rated power 1000W Peak power 2000W
PV Input Max 15~25V 150W

Suggested

Max 18V150W

Working Temperature Range Charge: 0°C--45°C  
Discharge: -20°C--60°C
Storage Temperature -10°C--50°C  

 

4. The parameter for BMS

 

 4. 1Table 1Technical Parameter

No. Item Parameter Remark
Technical Parameter for LY-MP091-A
1 Working Voltage Range 8.8~26V DC
2 Working Consumption <500uA @12.8V
3 Sleep Consumption <100uA @12.8V
4 WorkingTemperature Range
-20~80℃
 
5 WorkingHumidity Range 15%~90% No condensation
6 Overall VoltageTestAccuracy <1%FSR  
7 TemperatureTest Range
-30~90℃
 
8 TemperatureTestAccuracy <±3℃  
9 CurrentTestAccuracy <1%FSR  
10 SOCEstimateAccuracy <8%  
11 Max. Continuous Discharge Current 100A  
12 Max. Continuous charge Current 30A  
13 Communication Port SMBus v1.1  
Technical Parameter for LY-MP091-B
1 Working Voltage Range 8~28V  
2 Sleep Consumption <500uA @12.8V
3 DC Output USD 3 Output 5V/2.1A
4 USB QC3.0 output Max 18W
5 Type-C Max 60W
6 2*DC12V Output Max 7A
7 DC12V Switch Max 10A
8 Inverter Control Signal  
9 Communication Port 12C Communication Port SMBus communicatewith BMS LY-MP091-A to gain battery information
10 Button 2 Independent Button DC12V, USB, AC, Control DC12V, USB andAC separately
11 Display LCD Screen Indication of batteryinformation
12 Working Temperature Range
-20~80℃
 
13 Working Humidity Range 15%~90% No condensation

 

4.2 Table 2 Protection Value

 

Item Trigger Condition Standard Parameter Remark
Over charge protection and recovery for cell Over charge inspect voltage 3.70V±10mV  
Over charge release voltage 3.55V±10mV  
Over discharge protection and recovery for cell Over discharge inspect voltage 2.5V±10mV  
Over discharge release voltage 2.8V±10mV  
Charge over current Charge over current protect 1 25000mA±2A  
Charge over current protect 2 40000mA±2A  
Discharge over current Discharge over current protection 1 100000mA±2A  
Discharge over current protection 2 125000mA±2A  
Short circuit Load short circuit Yes  
Charge over temperature Charge over temperature protection 55℃±2℃  
Protection time delay 5S  
Charge high temperature recovery 55℃±2℃  
Charge low temperature Charge low-temperature protection 0℃±2℃  
Protection time delay 5S  
Charge low-temperature recovery 5℃±2℃  
Discharge over temperature Discharge over temperature protection 60℃±2℃  
Protection time delay 5S  
Discharge high temperature recovery 55℃±2℃  
Discharge low temperature Discharge low temperature protection
-20℃±2℃
 
Protection time delay 5S  
Discharge low temperature recovery
-10℃±2℃
 
Standard USB Over current protection 2.5A±0.2A Recover in 10s afterload is disconnected
DC12V Over current protection 7A±0.5A Recover in 10s afterload is disconnected
DC12V switch Over current protection 10A±0.5A Recover in 10s afterload is disconnected
USB QC3.0 Protection power 18W±0.5W Disconnect load andreconnect
Type-C Over current protection 4A±0.2A Disconnect load and reconnect, output power shall be <60W

 

5. Product Circuit diagram

 

6. Inverter Parameter

Model PS1000-1211 PS1000-1222
Output Rated power 1000W
Peak power 2000W
AC voltage 110V AC 220V AC
Output frequency 60Hz±0.5Hz 50Hz±0.5Hz
Output Waveform Pure sine wave(THD<3%)
Input Battery voltage 12V
Battery voltage range DC10~15V
DC current 110A
Work efficiency 90%
Battery input protetion Fuse 40A*4
Battery low voltage alarm 11V±4%
Battery low voltage shutdown 10V±4%
Battery with reverse protection Blow off an internal fuse
Output protection over temperature protection Whenthe temperature of the temperature control point reaches 70℃±3℃, the output will be stopped, and the built-in buzzer will have 5 alarmsat an interval of 1 second (continuous mode).
Overload protection Whenthe load reaches 115% ~ 145%, the alarm indicates that after 10 seconds, the output is turned off, and the switch needs to be reset for recovery
Whenthe load reaches more than 145%, shut off the output for 2 seconds
Output short circuit protection (self-recovery mode) turn off the output voltage, remove the load fault automatic recovery

7. Packing drawing

8. Electrical Performance for cell

Item Test Condition Specification
Open-Circuit Voltage The open-circuit voltage shall be measured within 24hours after standard charge ≥13.2V
Battery Capacity The discharge time at 40A shall be measured after standard charge at 20±5℃ and rest 30mins ≥100%
Cycle Life The discharge time on standard discharge shall be measured after 2000 cycles of standard charge and discharge at 20±5℃ ≥80%
Charge(capacity) retention The discharge time at 40A shall be measured after standard charge and then storage at 20±5℃ for 28days ≥80%
Temperature Characteristics After standard charging at 20±5℃, laying the battery at 55℃ for 2hour, then discharge at 40A to 10V, record the discharge time ≥80%
Temperature Characteristics After standard charging at 20±5℃, laying the battery at -10℃ for 4hour, then discharge at 40A to 10V, record the discharge time ≥60%

 

9. Machanical Performance for cell

 

Item Test Condition Specification
Crush Test A battery is to be crushed between two flat surfaces. The force for the crushing is to be applied by a hydraulic ram with a 32mm diameter piston. The crushing is to be continued until a pressure reading of 17.2mmPa is reached on the hydraulic ram, applied force of 13kN. Once the maximum pressure has been obtained it is to be released. No fire,No explosion
Drop Test The battery has only two axes of symmetry in which case only two directions shall be tested. The battery is to be dropped from a height of 1 meter twice onto concrete ground. No explosion, No fire, No smoke
Vibration A full-charged battery is to be subjected to simple harmonic motion with an amplitude of 1.6mm total maximum excursion. The frequency is to be varied at the rate of 1 hertz per minute between 10 and 55 hertz. The cell shall be vibrated for 30 minutes per axis o XYZ axes. No leakage, No Fire, No explosion

 

10. Cell Safety Performance

Item Test Condition Specification
Over charge At 20±5℃, charging battery with constant current 1C to voltage 4V, then with constant voltage 4V till current decline to 0. No explosion, No fire
Over discharge At 20±5℃, according to the requirement of the standard of discharge after discharge to termination voltage, 30 m Ω external load discharge within 24 hours. No explosion, No fire
Short-circuit At 20±5℃, Standard charge, across the electrodes of the battery with a less than 50 m Ω wire connection, 6 hours No explosion, No fire The temperature of the surface of the cell are lower than 150℃
Heating Battery is heated in a circulating air oven at a rate of 5±2℃ per mins to 130℃, an then placed 30 mins at 130℃ No explosion, no fire

 

11. Our Company

    Shenzhen AMT Technology Co., Ltd, a professional manufacturer of LiFePO4 Lithium ion batteries. Our LiFePO4 Lithium ion batteries provide steady discharge & charge performance in a lighter volume, are applicable for different kinds of EV/PHEV/UPS/Storage energy/Starting power supply.Have passed ISO 9001, ISO 14000,UL1642/UN38.3/CB(IEC62133)/BIS/ROHS/CE certification, With our advanced equipments, we can provide customized product with high quality.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen AMT Technology Co., Ltd.
Location Room 14F,Building A2,Zhujiang Plaza,Longxiang Road,Longgang District,Shenzhen,Guangdong,China
Contact Person Sales Manager

Request A Quote

Please check your email address.
Your message must be at least 20 characters.