Disposable Automatic Flushing Closed Suction Catheter 72H
Price:
2.6-4.5usd/pc
MOQ:
1 Pieces
Delivery Time:
3-45 Days
Brand:
MCR / OEM
Product Description
Disposable Automatic Flushing Closed Suction Catheter 72H
Product Parameters
| Product Code | Size | Colour Code | Tube OD (mm) | Length of Tube (mm) |
| MC-07210 | Adult/72H/Endotracheal | Black | 10Fr(3.35mm) | 600mm |
| MC-07211 | Adult/72H/Endotracheal | White | 12Fr(4.05mm) | 600mm |
| MC-07212 | Adult/72H/Endotracheal | Green | 14Fr(4.75mm) | 600mm |
| MC-07213 | Adult/72H/Endotracheal | Orange | 16Fr(5.45mm) | 600mm |
| MC-07200 | Adult/72H/Tracheostomy | Black | 10Fr(3.35mm) | 300mm |
| MC-07201 | Adult/72H/Tracheostomy | White | 12Fr(4.05mm) | 300mm |
| MC-07202 | Adult/72H/Tracheostomy | Green | 14Fr(4.75mm) | 300mm |
| MC-07203 | Adult/72H/Tracheostomy | Orange | 16Fr(5.45mm) | 300mm |
Feature:
Reduce oxygen desaturation by allowing constant patient ventilation.
Reduces the potential of infection to the clinician.
Maintains a sealed airway to reduce exposure to secretions.
Provide maximum suction and is designedto reduce trauma.
Enhance patients safety avoids disconnectionfrom the ventilator during catheter change-out or untangling of lines
Color coded rings provide fast size recognition.
Application
1. Choose the appropriate specification according to clinical needs, 600mm length is used with Endotracheal tube and 450mm length is used with Tracheostomy tube. Check whether the package is complete. If the package is damaged, do not use it.
2. Tear open the package to check whether the product in the package is in a sound and good condition, please note sterile operation.
3. Turn on the vacuum regulator and adjust the pressure as appropriate. Then turn off the protective cap and connect the machine end to the vacuum tubing, and connect the patient end to tracheal tube and breathing circuit.
4. Before suctioning commences, ensure that the suction control valve and the irrigation ports is closed. When suction operation, open the suction control valve, then grip the four-way valve in one hand and with the other hand feed slowly the suction catheter into the tracheal tube until the required depth by observing the tube scale.
5. Once the suction catheter is in the desired depth depress the vacuum control valve to apply suction. (If the patient has tenacious secretions, sterile 0.9% NaCl may be instilled by the irrigation port prior to suctioning to facilitate loosening and removal of the secretions.).
6. After suctioning, remove suction catheter until the protective sleeve is straight and close the suction control valve.
7. It is possible that repeat the suctioning procedure,until secretions are cleared from the airway and breath sounds are improved. But ensure stable vital signs prior to reinsertion of the catheter.
8. When close the suction control valve and open the protective cap, rinse the suction tubing in water after the procedure to prevent clogging of the vacuum apparatus.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
MCREAT (GUANGZHOU) BIO-TECH CO.,LTD
Location
3rd-Floor, B15 Huachuang Industry Area, Jinshan Cun, Shiji Town, Panyu District, Guangzhou, Guangdong China
Contact Person
Irina Li