● DC rated voltage: 1 channel: -48VDC
● Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
● RS485(MODBUS-RTU)
● LED display
● DIN 35 mm
5G Tower Base DC Multi Circuit Energy Meter AMC16-DETT
Price:
$92.20 / Piece
MOQ:
1 Piece
Delivery Time:
Negotiable
Brand:
Acrel
Product Description
Product Description

AMC16-DETT Base Station DC Energy Meter
Dimensions(mm)

Function
Accuracy
1%In≤I≤10%In error±2.5%;I>10%In error±2%
Voltage range
-40V~-60VDC
Power consumption
≤2W( no hall power supply output)
Power supply output
+12V/100Ma, -12V/50mA
Power consumption
≤2W( no hall power supply output)
1%In≤I≤10%In error±2.5%;I>10%In error±2%
Voltage range
-40V~-60VDC
Power consumption
≤2W( no hall power supply output)
Power supply output
+12V/100Ma, -12V/50mA
Power consumption
≤2W( no hall power supply output)


Dimension(L*W*H)
89.7*87.8*52mm
Installation
DIN 35 mm
Clock
≤0.5S/d(23℃), ≤1S/d(-20℃-60℃)
Current
1.2 times continued
89.7*87.8*52mm
Installation
DIN 35 mm
Clock
≤0.5S/d(23℃), ≤1S/d(-20℃-60℃)
Current
1.2 times continued
Appearance



Wiring

Function and parameter
|
Input
|
DC rated voltage
|
1 channel:-48VDC
|
|
|
|||
|
|
DC current
|
6 channels hall sensors : total 200A/5V, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd channel reserve 100A/5V.
|
|
|
|||
|
|
Commercial power monitoring
|
1 channel :0-5 VDC
|
|
|
|||
|
|
Overload capacity
|
Voltage:1.2 times continued, 2 times continued 1 s.
Current: 1.2 times continued, 10 times continued 1 s.
|
|
|
|||
|
Accuracy(superposition hall sensors)
|
|
1%In≤I≤10%In, error ±2.5%; I>10%In; error ±2%
|
|
|
|||
|
Measurement resolution
|
|
Voltage: 0.01 V, Current: 0.01 A, Power: 0.01 kw, Energy: 0.01 kwh
|
|
|
|||
|
Functions
|
Basic function
|
Monitor device system time, total voltage, total current, power, energy, each channel voltage, current, power , energy;LED display, RS485 communication;
|
|
|
|||
|
|
Metering function
|
Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max.current, the meter starts.
Shunt running current: When there is no current in the current circuit of the meter, and 85%~125% of the rated voltage is applied on the voltage circuit, the calculator shall not have more than one digital change.
|
|
|
|||
|
|
Alarm function
|
DC under-voltage, DC over-voltage, one power down, module voltage loss, metering branch error, internal program error, clock error, memory failure, AC input power failure.
|
|
|
|||
Certificate





Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Jiangsu Acrel Electrical Manufacturing Co., LTD.
Location
No. 9 Xincheng Road,Chengjiang Street, Jiangyin City, Jiangsu Province,China
Contact Person
Dina Huang