Magic Series HD96 Fiber Optic Cassette Magic Fiber Patch Panel Cassette
Magic Series HD96 Fiber Optic Cassette Magic Fiber Patch Panel Cassette
HD96 Fiber Optic Cassette provides a centered cable distribution to management rooms, equipment rooms and data center information points in smart building structured cabling system. It exceeds all parameters specified in IEC 61754, IEC 61755 standards.
The cassette can be installed in Magic series Modular Patch Panels, used in combination with fiber optic splicing, MPO/MTP pre-term fiber optic cables and fiber optic patch cords, and provide high performance, high density inlets and outlets for fiber optic information points.
There are both splicing and pre-terminated types. The former supports 24 splices, while the latter provides a variety of models, such as MPO/MTP to SC, LCD, MPO/MTP, and OS2, OM3, OM4, OM5. With LC adapter in use, it can house 96 fibers within 1U, which realizes optimal space utilization and provides a strong guarantee for structured cabling installation, maintenance and management.
TC Fiber Optic Cassette Features
- Plastics gives the main housing good mechanical property. Modular design offers both splicing and pre-terminated types.
- With SCD/LCQ adapters in front (in combination with 1.6mm ultra thin patch cords from TC) and M16 cable gland (4-8mm diameter ) in rear, each splice cassette holds up to 24 splices and is equipped with a micro splice tray as well as bend radius protection. It is suggested that G.657.A1 singlemode pigtails should be used to reduce macro bending losses of singlemode fibers.
- Pre-terminated type has two MPO/MTP-LC fan-outs built-in with low losses. 100% original, it exceeds all parameters specified in IEC 61754, IEC 61755 and other international standards.
- It is compatible with Type A and Type B wiring as well as exclusive Type T wiring (the same wiring on both terminals) by TC. High density that 96 fibers within 1U, together with pretermination ensures high space utilization and quick deployment in data center.
Application Standards
GB/T 18233 (ISO/IEC 11801); GB 50311; TIA/EIA568-C.2
Technical Details
| Specifications | OM3/OM4 | 0M5 | G.657.A2 LC-PC | G.657.A2 LC-APC | |
| Capacity | 24 core | 24 core | 24 core | 24 core | |
| Rear | Connector | 2 x MPO/MTP female | 2 x MPO/MTP female | 2 x MPO/MTP female | 2 x MPO/MTP female |
| Connector Type, Grinding Type |
Low loss, PC 0˚ | Low loss, PC 0˚ | Low loss, APC 8˚ | Low loss, APC 8˚ | |
| Insertion Loss IL (Typical) | ≤ 0.15dB | ≤ 0.15dB | ≤ 0.18dB | ≤ 0.18dB | |
| Insertion Loss IL (Max.) | ≤ 0.30dB | ≤ 0.30dB | ≤ 0.30dB | ≤ 0.30dB | |
| Return Loss RL (Typical) | ≥ 35dB | ≥ 35dB | ≥ 70dB | ≥ 70dB | |
| Return Loss RL (Min.) | ≥ 30dB | ≥ 30dB | ≥ 65dB | ≥ 65dB | |
| Connectivity Method | A, B, T | A, B, T | A, B, T | A, B, T | |
| Color Code | Aqua, Violet | Lime green | Black | Black | |
| Front | Connector Grinding Type |
24 x LC PC 0˚ | 24 x LC PC 0˚ | 24 x LC PC 0˚ | 24 x LC APC 8˚ |
| Fiber Stub | ZrO2 | ZrO2 | ZrO2 | ZrO2 | |
| Insertion Loss IL (Typical) | ≤ 0.10dB | ≤ 0.10dB | ≤ 0.10dB | ≤ 0.10dB | |
| Insertion Loss IL (Max.) | ≤ 0.25dB | ≤ 0.25dB | ≤ 0.25dB | ≤ 0.25dB | |
| Return Loss RL (Typical) | ≥ 40dB | ≥ 40dB | ≥ 50dB | ≥ 75dB | |
| Return Loss RL (Min.) | ≥ 35dB | ≥ 35dB | ≥ 45dB | ≥ 65dB | |
| Tube | ZrO2 | ZrO2 | ZrO2 | ZrO2 | |
| Color Code | Aqua, Violet | Lime green | Blue | Green | |
| Jacket Material | PEI | PEI | PEI | PEI | |
| Dust Cover (duplex) | White or Transparent | White or Transparent | White or Transparent | White or Transparent | |
| Color Code of Fan-Out Fibers |
IEC 60304 | IEC 60304 | IEC 60304 | IEC 60304 | |
| Quantity of Fan-Outs | 2 x 12 core | 2 x 12 core | 2 x 12 core | 2 x 12 core |