Temperature Humidity Test Chamber TH-80 TH-150 TH-225 -40℃ to 150℃ 20-98% RH
- Temperature and humidity environmental control test chamber designed to simulate test environments with varying temperature and humidity conditions.
- Cyclic testing includes climatic conditions such as holding test, cooling-off test, heating-up test, moistening test, and drying test.
- Cable port with flexible silicone plug for cable routing, allowing the test unit to operate under real working conditions.
- Uncovers test unit weaknesses in a short-term test through accelerated time effect.
- High performance with quiet operation at 68 dBA.
- Space-saving design suitable for flush installation to wall.
- Full thermal break around the doorframe.
- One 50 mm diameter cable port on the left, fitted with a flexible silicone plug.
- Accurate wet/dry-bulb humidity measurement system for easy maintenance.
- PLC controller dedicated to the test chamber.
- Step types include ramp, soak, jump, auto-start, and end.
- RS-232 interface for connection to a computer for data output.
| Parameter | TH-80(A~F) | TH-150(A~F) | TH-225(A~F) |
|---|---|---|---|
| Internal Dimension W×H×D (mm) | 400 × 500 × 400 | 500 × 600 × 500 | 600 × 750 × 500 |
| External Dimension W×H×D (mm) | 950 × 1650 × 950 | 1050 × 1750 × 1050 | 1200 × 1900 × 1150 |
| Temperature Range | Low Temperature (A: 25℃, B: 0℃, C: -20℃, D: -40℃, E: -60℃, F: -70℃); High Temperature 150℃ | ||
| Humidity Range | 20%–98% R.H. (10%–98% R.H. / 5%–98% R.H. is optional and requires a dehumidifier) | ||
| Control Accuracy of Temperature and Humidity | ±0.5℃; ±2.5% R.H. | ||
| Temperature Rising / Falling Velocity | Temperature rising approx. 0.1–3.0℃/min; temperature falling approx. 0.1–1.0℃/min (falling min. 1.5℃/min is optional) | ||
| Optional Accessories | Inner door with operation hole, recorder, water purifier, dehumidifier | ||
| Weight (kg) | 150 | 180 | 250 |
- Imported LCD display screen capable of displaying the measured value as well as the set value and time.
- Fixed condition or programmable condition can be set.
- Fixed condition setting time range: 0 – 99999 H 59 MIN.
- Programmable mode can set 269 different programs at the same time; each program can set several segments to perform cycle testing.
- Each program can have a maximum of 50 segments with different temperature settings; segment running time max. 530 hr 59 min; max. 13450 cycles.
- Power-off memory device allows the program to resume from where it left off.
- The control unit features slope control of temperature and a self-calibration temperature function.
- Equipped with timer signal output relay.
- Temperature sensor adopts DIN PT-100Ω.
We are a testing equipment manufacturer with a long history. Over the past 28 years, we have devoted ourselves to simulation environmental testing equipment and mechanical vibration and shock testing machines. The Temperature Humidity Environmental Control Test Chamber is one of our star products, and we have obtained CE certification for this machine.
A: PP film first, then 10 mm foam between the machine and the case, and outside is a standard export plywood case.
A: T/T 50% as deposit, and 50% before delivery. We will show you the photos of the products and packages before you pay the balance.
A: EXW, FOB, CIF.
If you need more information about the Temperature Humidity Environmental Control Test Chamber, please feel free to contact us.
Get in Touch