Electrodynamic Shaker Table For Vibration Test Of Cells And Batteries SAE J2464
Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464
System Force Rating
Vibration systems have output force ratings typically expressed in terms of:
Sine force: lbs (kN) pk
Random Force: lbs (kN) rms
Shock Force: lbs (kN) pk
The stated random force rating assumes a certain spectrum shape (usually flat) over a given frequency range (usually 5 Hz – 2,000 Hz) and a certain minimum mass load on the shaker. If these conditions are different from your test requirements, a new calculation of the effective random force rating may be necessary. These output force ratings provide a starting point for the Force (F) parameter in F = M*A*1.3
Test system composition
1. One-piece horizontal vibration generator
2. Vertical expansion table
3. Cooling fan with muffler
4. Digital switching power amplifier
5. Multi-function vibration control measuring instrument.
Specification
| Name | Automobile Battery EN50604 IEC62133 UN38.3 Vibration Test Bench for Lab testing | ||||||||
| Model | Rated Sine Force (N) | Rated Random Force (N) | Frequency Range (Hz) | Rated Acceleration (m/s2) | Rated Speed(m/s) | Rated displacement (p-p)mm | Max. Loading (Kg) | moving coil (Kg) | Dimension of Moving coil (mm) |
| ES-6 | 6000 | 6000 | 3-3500 | 1000 | 1.6 | 25 | 180 | 6.5 | Φ230 |
| ES-6a | 6000 | 6000 | 3-3500 | 1000 | 1.6 | 51 | 250 | 12 | Φ230 |
| ES-10 | 10000 | 10000 | 3-3000 | 1000 | 1.8 | 51 | 270 | 14 | Φ240 |
| ES-20 | 20000 | 20000 | 3-3000 | 1000 | 1.8 | 51 | 300 | 30 | Φ320 |
| ES-30 | 30000 | 30000 | 3-2800 | 1000 | 1.8 | 5l | 450 | 40 | Φ450 |
| ES-40 | 40000 | 40000 | 3-2800 | 1000 | 1.8 | 51 | 500 | 50 | Φ450 |
| ES-50 | 50000 | 50000 | 3-2700 | 1000 | 1.8 | 51 | 750 | 50 | Φ450 |
| ES-60 | 60000 | 60000 | 3-2700 | 1000 | 1.8 | 51 | 750 | 60 | Φ450 |
| ES-100 | 100000 | 100000 | 3-2500 | 1000 | 1.8 | 51 | 1000 | 90 | Φ450 |
2. Two-magnetic circuit, magnetic flux leakage low, compact structure and rational.
3. Rocker Rod roller bearings straight and import-oriented composite body stiffness orientation, eccentric load capacity.
4. Trunnion isolation foundation dedicated to hormone use, the installation of mobile convenience.
5. Advanced technology move around the system to ensure that the dynamic circle of high reliability.
6. New duct design and enhance the cooling effect.
7. Static stiffness, dynamic stiffness of the bearing small balloon, raising the vibration table bearing capacity, improve low-frequency performance.
If you need more information about Electrodynamic Shaker table for Vibration Test of Cells and Batteries SAE J2464, please feel free to send your inquiries.