1.0 Mpa Zone Heating Valves 3 Wires 2 Points DN40 Water Flow Control
3 wires 2 points control zone heating valves, hot water flow control valves 95 ℃
Product Description
Our heating zone control valves are available from DN15 to DN32, and many different thread connection ports. This CW25S zone control valve has the manual OPEN/CLOSE function in case of no electricity, lift the manual handle and turn it on or off, and it will get heat when any of the other zones call for heat. They can used for hot water flow controls, priority zoning circulators, or fan controls, central heating and cooling systems.
Features
1. Extreme long service life span ;
2. Manual Override, the valve can be operated when power failure;
3. Mini dimension and position indicator;
4. Good sealing performance, IP65 enclosure.
Application
- HVAC system heating, ventilation, air conditioning
- Baseboard/radiant heating
- Convectors
- Fan coil units
- Underfloor heating
- Unit ventilators
- VAV reheat
Advantages
- Sturday valve body with reasonable structure design, and best material to be used
| No. | Ours | Normal products |
| Valve shaft seal | Quadruple seals | Dual seals |
| Nut seal | Auto super anaerobic glue coating, Consistent torque tightening | Manual anaerobic glue, unevenly, non consistent torque tightening |
| Seal between valve body and housing | Seal groove | none |
| Torque | Smoothly and light | Heavy, non consistently |
| Drainage | Yes | none |
Technical data
| Model | 20P-1.0A |
| Work Amp (mA) | Max 80 |
| Protection | IP65 |
| Power (W) | <2 |
| Operate Pressure (Mpa) | PN10 |
| Torque (NM) | 2 |
| Dia range | DN8-32 (Straight); DN15-20 (Tee, three way) |
| Open/close (S) | Straight: < 7s; Three way: <13s |
| Work volt. (V) | DC3-6V, DC12V |
| Media temp (℃) | 0-90 |
| Control | CR01, CR02, CR05 |
| Valve body material | Connection port | Diameter | D | L | H | W |
| (mm) | (Kg) | |||||
| Brass | Both female thread full diameter | DN8 | 8 | 46 | 31 | 0.232 |
| DN10 | 8 | 46 | 31 | 0.231 | ||
| DN15 | 15 | 57 | 38 | 0.308 | ||
| DN20 | 15 | 66 | 38 | 0.389 | ||
| DN25 | 20 | 72 | 47 | 0.478 | ||
| 3-way vertical | DN15 | 12 | 63 | 49 | 0.31 | |
| DN20 | 15 | 66 | 53 | 0.367 | ||
| Female-male thread | DN15 | 15 | 63 | 38 | 0.307 | |
| DN20 | 15 | 66 | 38 | 0.337 | ||
| DN32 | 20 | 76 | 50 | 0.569 | ||
| Both male thread | DN15 | 15 | 68 | 38 | 0.299 | |
Wiring options
- Two wires and reverse polarity (DC3-6V / DC12V)
1. Connecting SW to OPEN , the valve opens , getting the position ,automatically power off, the valve remain fully open position
2. Connection SW to CLOSE , the valve close , getting the position ,automatically power off, the valve remains side passes position(fully closed)
- Three wires and two control points (DC3-6V / DC12V / DC24V)
1. Connecting SW to OPEN, the valve opens , getting the position ,automatically power off, the valve remain fully open position
2. Connection SW to CLOSED, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)
Note: AC24V/AC220V can only be used for 50K series electric valves
- Three wires and one control point (DC3-6V/12V)
1. Connecting SW, the valve opens , getting the position ,automatically power off, thevalve remain fully open position
2. Disconnecting SW, the valve close , getting the position ,automatically power off, the valve remains side passes position (fully closed)
Note: When power is DC voltage and Red Wires is “+”,Blue wire is “—”
- Two wires and power off return (DC3-6V/ADC9-24V/AC220V)
1. SW connecting, the valve open, getting the position and the power off automatically, the valve remains fully open/close position
2. SW disconnecting, the valve close, getting the position and power off automatically, the valve remains fully open/close position
- Five wires micro conntroller with signal feedback (DC3-6V/12V)
1. Connecting SW and OPEN, the valve opens, getting the position green wire output the OLS signal, the controller tests the signal OLS, connect SW to STOP, the valve stops and remains fully open position
2. Connecting SW and CLOSE, the valve close, getting the position red wire output the CLS signal, the controller tests the signal CLS, connect SW to STOP, the valve stops and remains fully close position,
Note: Please make sure the signal wires "red", "black" and "green" be connected at first, then connect the power wires " yellow" and "blue".
Factory show


Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.