VICTOR 24 Portable Multifunction Process Calibrator Rtd Calibration Equipment
Portable Multifunction Process Calibrator Rtd Calibration Equipment
VICTOR 24 Handheld Multifunction Process Calibrator 0.02% Accuracy Two Independent Channels For Input And Output 5 Digits Display
Introduction
This multifunction process calibrator (the calibrator in the following) is a handheld, battery-operated instrument that measures and sources electrical and physical parameters. (See Table 1)
Table 1 Source and Measurement Function
|
Measurement Function Sourcing Function |
DCV |
DCI |
OHM |
FREQ |
TC |
RTD |
CONT. |
||
|
LOOP OFF |
LOOP ON |
||||||||
|
DCV |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
DCI |
RAMP ON |
× |
× |
× |
× |
× |
× |
× |
× |
|
RAMP OFF |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
OHM |
● |
● |
● |
● |
● |
● |
● |
● |
|
|
FREQ |
● |
● |
● |
● |
× |
● |
● |
● |
|
|
TC |
● |
● |
● |
● |
● |
× |
× |
● |
|
|
RTD |
● |
● |
● |
● |
● |
× |
× |
● |
|
Except the functions listed in Table 1, the calibrator has the following features as well:
-
You can operate the measurement and source function simultaneously. The LCD screen is divided into two separate districts, whose upper part displays measurement information and lower part displays source information.
-
TC measurement/source terminals and built-in lead connector of same temperature (RJ compensation with auto-reference joint point)
-
Manual step source and auto -step and sweeping –step source
-
Room temperature monitoring under any operation
-
Measurement/source temperature monitoring function
-
Measurement/source mA% display
-
Measurement wave-filter function
-
Measurement manual-holding function
-
Pressure source auto-holding function
-
Contact Us
To purchase parts, obtain operation help or address of the vendor or service center nearest to you, please call us or visit our web (see the bottom page of the Manual).
-
Standard Accessories
Make sure that the package contains all the accessories listed below. And if you find they are damaged or any of them is missing, please contact the vendor from which you purchased the product as soon as possible. Refer to the replacing part list in 15.3 in the Manual if you want to order the replacing parts.
-
Two pair of Industrial testing Lead (H000002)
-
A pair of Testing Probe (H000000)
-
A pair of Alligator clip (H010000)
-
A quick reference guide
-
A User's Manual
-
One Fuse 50mA/250V
-
One Fuse 100mA/250V
Techincal Data
|
Project |
Model |
VICTOR 24 |
VICTOR 25 |
|
|
Source |
DC millivolt |
Range |
-10 ~ 110mV |
-10 ~ 110mV |
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
|
Resolution |
1uV |
1uV |
||
|
DC voltage |
Range |
-0.1 ~ 11V |
-0.1 ~ 11V |
|
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
|
Resolution |
10uV/0.1mV |
10uV/0.1mV |
||
|
DC current |
Range |
0 ~ 22mA |
0 ~ 22mA |
|
|
Accuracy= |
0.02%+0.02% |
0.02%+0.02% |
||
|
Resolution |
1uA |
1uA |
||
|
Sink current |
Range |
0 ~ 22mA |
0 ~ 22mA |
|
|
Accuracy= |
0.02%+0.02% |
0.02%+0.02% |
||
|
Resolution |
1uA |
1uA |
||
|
External power |
5 ~ 28V |
5 ~ 28V |
||
|
Resistance |
Range |
0 ~40KΩ |
0 ~40KΩ |
|
|
Accuracy= |
0.02%+0.02% |
0.02%+0.02% |
||
|
Resolution |
0.01Ω/0.1Ω/1Ω |
0.01Ω/0.1Ω/1Ω |
||
|
Thermocouple |
Range |
R/S/K/E/J/T/B/N |
R/S/K/E/J/T/B/N |
|
|
Accuracy |
0.4℃ |
0.4℃ |
||
|
Resolution |
0.1℃/1℃ |
0.1℃/1℃ |
||
|
RTD |
Range |
Pt100/Pt200/Pt500/ |
Pt100/Pt200/Pt500/ |
|
|
Accuracy |
0.2℃ |
0.2℃ |
||
|
Resolution |
0.1℃ |
0.1℃ |
||
|
Frequency |
Range |
1Hz ~110KHz |
1Hz ~110KHz |
|
|
Accuracy |
±2words |
±2words |
||
|
Resolution |
0.01Hz/1Hz/0.1KHz/2KHz |
0.01Hz/1Hz/0.1KHz/2KHz |
||
|
Pulse |
Frequency |
N/A |
1Hz ~10KHz |
|
|
Range |
1 ~100000cyc |
|||
|
Accuracy |
±2words |
|||
|
Resolution |
1cyc |
|||
|
Switch |
Range |
N/A |
1Hz ~110KHz |
|
|
Accuracy |
±2words |
|||
|
Resolution |
0.01Hz/1Hz/0.1KHz/2KHz |
|||
|
Pressure |
Range |
N/A |
Depends on the pressure module |
|
|
Accuracy= |
Depends on the pressure module |
|||
|
Resolution |
5 digit display |
|||
|
Measure |
DC millivolt |
Range |
-5 ~ 550mV |
-5 ~ 550mV |
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
|
Resolution |
1uV/10uV |
1uV/10uV |
||
|
DC voltage |
Range |
-0.5 ~ 55V |
-0.5 ~ 55V |
|
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
|
Resolution |
0.1mV/1mV |
0.1mV/1mV |
||
|
DC current |
Range |
-5 ~ 55mA |
-5 ~ 55mA |
|
|
Accuracy= |
0.02%+0.01% |
0.02%+0.01% |
||
|
Resolution |
1uA |
1uA |
||
|
Resistance |
Range |
0 ~5.5KΩ |
0 ~5.5KΩ |
|
|
Accuracy= |
0.05%+0.02% |
0.05%+0.02% |
||
|
Resolution |
0.01Ω/0.1Ω |
0.01Ω/0.1Ω |
||
|
Thermocouple |
Range |
R/S/K/E/J/T/B/N |
R/S/K/E/J/T/B/N |
|
|
Accuracy |
0.7℃ |
0.7℃ |
||
|
Resolution |
0.1℃/1℃ |
0.1℃/1℃ |
||
|
RTD |
Range |
Pt100/Pt200/Pt500/ |
Pt100/Pt200/Pt500/ |
|
|
Accuracy |
0.3℃ |
0.3℃ |
||
|
Resolution |
0.1℃ |
0.1℃ |
||
|
Frequency |
Range |
3 Hz~50KHz |
3 Hz~50KHz |
|
|
Accuracy |
±2words |
±2words |
||
|
Resolution |
0.01Hz/0.1Hz/1Hz |
0.01Hz/0.1Hz/1Hz |
||
|
Switch |
Range |
N/A |
CLOSE/OPEN |
|
|
Threshold |
200 ~300Ω |
|||
|
Pressure |
Range |
N/A |
Depends on the pressure module |
|
|
Accuracy= |
Depends on the pressure module |
|||
|
Resolution |
5 digit display |
|||
|
Continuity beeper |
Range |
0 ~500Ω |
0 ~500Ω |
|
|
Accuracy |
≤50Ωsound |
≤50Ωsound |
||
|
Resolution |
0.01Ω |
0.01Ω |
||
|
Loop power supply |
Range |
24V |
24V |
|
|
Accuracy |
±10% |
±10% |
||
|
The maximum current |
22mA |
22mA |
||
|
Other functions |
Backlight |
√ |
√ |
|
|
Auto Power-off |
√ |
√ |
||
|
Charging function |
√ |
√ |
||
|
Room temperature display |
√ |
√ |
||
|
Battery detection |
√ |
√ |
||
|
The ramp signal |
√ |
√ |
||
|
Communication function |
RS232 serial communication, can realize remote control instrument by the device driver software. |
RS232 serial communication, can realize remote control instrument by the device driver software. |
||
|
Characteristic |
||||
|
Safety |
EN61010-1:2001 |
EN61010-1:2001 |
||
|
Withstand voltage |
The input and output AC350V/1 minutes |
The input and output AC350V/1 minutes |
||
|
Insulation |
The input and output DC500V /50MΩ. |
The input and output DC500V /50MΩ. |
||
|
EMC |
EN61326-1:2006 |
EN61326-1:2006 |
||
|
Authentication |
CE |
CE |
||
|
Display |
Double display on the LCD screen |
Double display on the LCD screen |
||
|
Power supply |
4×1.5V AAA Alkaline battery |
4×1.5V AAA Alkaline battery |
||
|
Size |
205 × 95 × 42 mm |
205 × 95 × 42 mm |
||
|
Weight |
About 500g |
About 500g |
||
|
Standard Quantity Per Carton |
10pcs |
10pcs |
||
|
Standard Carton Measurement |
395mm*385mm*260mm |
395mm*385mm*260mm |
||
|
Standard Carton Cross Weight |
12.4Kg |
12.4Kg |
||
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.