VICTOR Digital Clamp Meter 5999 Counts AC DC 600V 600A With Live NCV Flashlight
VICTOR 606+ 606A+ 606B+ 606C+ Digital Clamp meter 5999 counts AC/DC 600V 600A Clamp multimeter with Live NCV Flashlight True-RMS function
1. SUMMARIZE
This meter is a handheld automatic range digital multiemter which driven by battery. It can be used to measure such parameters as DCV, ACV, DCA and ACA, Resistance, Continuity Buzzer, Diode, Frequency etc.
2. SAFETY OPERATION RULE
The meter’s design is in accordance with the CE certification, meets the standard of IEC61010. Read the following before operation.
2-1. Input over range is prohibited in each range during the test.
2-2. Place the function knob to the proper range before measurement, in case damage the meter, do not switch the range during measurement.
2-3. Voltage less than 36V is safety voltage. To avoid electric shock, be careful when measuring voltage higher than 36V DC, 25V AC.
2-4. Don’t input voltage under the resistance, capacitance, diode, continuity test, frequency measurement.
5. TECHNICAL CHARACTERISTIC
| FUNCTION | 606+ | 606A+ | 606B+ | 606C+ | Accuracy |
| DCV | 200mV/2V/20V | 600mV/6V/60V | 600mV/6V/60V | 600mV/6V/60V | ±(0.5%+7) |
| 200V | 600V | 600V | 600V | ±(1.0%+ 20) | |
| 600V | / | / | / | ±(1.2%+ 20) | |
| ACV | 2V/20V | 6V/60V | 6V/60V | 6V/60V | ±(0.8%+ 10) |
| 200V | 600V | 600V | 600V | ±(1.2%+ 25) | |
| 600V | / | / | / | ±(1.5%+25) | |
|
LOW INPEDANCE ACV |
2V/20V | 6V/60V | 6V/60V | 6V/60V | ±(0.8%+ 10) |
| 200V | 300V | 300V | / | ±(1.2%+25) | |
| 300V | / | / | / | ±(1.5%+ 25) | |
| / | / | / | 300V | ±(1.0%+12) | |
| ACA | 2A | 6A | 6A | / | ±(4.0%+ 50) |
| 20A | 60A | 60A | / | ±(4.0%+ 35) | |
| 200A/600A | 600A | 600A | / | ±(4.0%+15) | |
| / | / | / | 60A/600A | ±(4.0%+10) | |
| DCA | / | / | / | 60A/600A | ±(4.0%+10) |
| RESISTENCE |
200Ω/2kΩ/20kΩ/ 200kΩ/2MΩ |
600Ω/6kΩ/60kΩ/ 600kΩ/6MΩ |
600Ω/6kΩ/60kΩ/ 600kΩ/6MΩ |
600Ω/6kΩ/60kΩ/ 600kΩ/6MΩ |
±(1.0%+ 5) |
| 20MΩ | 20MΩ | 20MΩ | 20MΩ | ±(1.5%+15) | |
| / | 60MΩ | 60MΩ | 60MΩ | ±(2.5%+20) | |
| CAPACITANCE | / | 6nF | 6nF | 6nF | ±(5.0%+40) |
| / | 60nF/600nF/6uF | 60nF/600nF/6uF | 60nF/600nF/6uF | ±(5.0%+ 10) | |
| / | 60uF/600uF/6mF | 60uF/600uF/6mF | 60uF/600uF/6mF | ||
| FREQUENCY | / |
10Hz/100Hz/1kHz/10kHz/ 100kHz/ 1MHz/10MHz |
10Hz/100Hz/1kHz/10kHz/ 100kHz/ 1MHz/10MHz |
10Hz/100Hz/1kHz/10kHz/ 100kHz/ 1MHz/10MHz |
±(0.3%+3) |
| TEMPERATURE | / | / |
-20℃~1000℃ (-4-1832)℉ |
-20℃~1000℃ (-4-1832)℉ |
/ |
| Display method |
LCD display 5999 count |
Max/Min | √ |
| Maximum display |
5999 count (606+ 1999count) |
Low Z | √ |
| Diode measurement | √ | Working temperature and humidity | (0-40) ℃ <75% |
| Data retention | √ | Storage temperature and humidity | (-10~50)℃<80% |
| NCV measurement | √ | Automatic shut-down | About 15 minutes |
| Fire detection | √ | Over-range display | the highest digit displays OL |
| Low voltage warning | √ | Unit symbol | √ |
| Flashlight lighting | √ | Open jaws | 35mm |
| True effective value | √ | input resistance | 10MΩ |
| INRUSH | 606C+ only | Sampling rate | 3 times/sec |
| VFC | 606C+ only | power supply | Two AAA batteries |












Get in Touch