Reliable Edge Computing Infrastructure Data Centers 1000U 1390kg
Price:
negotiate
MOQ:
negotiate
Delivery Time:
negotiate
Brand:
LionRock
Product Description
Security And Reliable Edge Computing Infrastructure
Introduction
Smart Micro Unit (SMU) data centre is a product that integrated UPS, power distribution board, air conditioning system, fire fighting equipment and power environment monitoring into a server style cabinet system. The product is a one stop solution to edge computing with increasing demand due to broad band network and 5G mobile network development.
Product Features
Rapid deployment
- Integrated design, fully factory assembly and tested before delivery
- Simple and quick site installation, a real plug and play solution
- SMU is designed to fully self-contained environment and dedicated machine room is not required
- Customised to specific operation environment possible
- Modular design and allow future expansion
High energy efficient and reduce carbon footprint
- Integrated Cabinet and sealed airduct design, effective separation of hot and cold air passages
- Line or rack type air conditioning unit installed close to server equipment
- Shorten and separated air path for efficient cooling
Security and Reliable
- Fully sealed and dust proof design with effective noise barrier
- Support N+1, 2N design to meet different infrastructure tier standards
- Emergency ventilation system in event of air conditioning failure, to safeguard IT equipment for proper shutdown and short terms operation
- Automatic fire extinguishing system to put out any fire in the cabinet protecting expensive equipment and personnel safety
- 10" touch screen HMI with camera, timely capture, monitoring the scene
Intelligent operation and maintenance
- Large local HMI (Human Machine Interface) with comprehensive system and performance information
- Remote Web base monitoring and multi-sites centralized management of real time and historical information with Mobile APPs in development
- Alarm can be sent through email/SMS/phone as well as local audio and visual indication, alarm analysis with fault handling recommendations
Application Area
- Any server required in electricity substation, railway station, financial outlets, government office, school, health care centre, facility security, small and medium enterprises, retail store and any operator business outlets
- Any indoor machine rooms

| System | Dimension (W x D x H) | 3000mm x 1350mm x 2000mm |
| Weight | 1390kg | |
| Installation | Indoor floor mount | |
| Cabling | Both top and bottom | |
| Maintenance Access | From the front and rear | |
| Airduct Sealing Option | Cold airduct sealing, hot airduct sealing or both are optional | |
| Cabinet Color | Black: RAL 9004 | |
| IT Equipment Space | 1000U | |
| Protection Level | IP20 | |
| Operating Temperature | -20ºC ~ 45ºC | |
| Number of Cabinet | 5 | |
| Air Conditioning System | Cooling Capacity |
15kW x 2
|
| Cooling Mode | Constant temperature (constant humidity is optional) | |
| Installation | Rack mount | |
| Air Supply Mode | Front air supply, rear air inlet | |
| Power Supply | Input Power Requirement |
380/400/415VAC, 50/60Hz, 3P+N+PE, 63A max
|
| AC Distribution |
63A/3P for UPS, 40A/3P x 2 for A/C, 20A/1P x 3 for PDUs,
16A/1P x 6 for other IT equipments
|
|
| Surge Protection | C class, In 20KA, Imax 40KA, 8/20µs | |
| ATS (5U) |
Optional (3P+N+PE, 63A max)
|
|
| IT Equipment Capacity |
10.5kVA/9kW
|
|
| UPS Capacity |
20kVA/17kW (10-40kVA optional and support A/C optional)
|
|
| UPS Input Voltage Rage |
138-485VAC, 45-65Hz, 3P+N+PE
|
|
| UPS Output Voltage Range |
380/400/415VAC, 50/60Hz, 3P+N+PE
|
|
| UPS Backup Battery | Lithium (LiFePO) | |
| UPS Backup Time | Std 15mins based on IT load (optional up to 60 minutes) | |
| UPS Maintenance Bypass | Standard configuration included | |
| PDU | 48 sockets, 16A x 12, 10A x 36. International sockets available | |
| Monitoring | Monitoring Platform | Support Web base access, multi-sites support, unified management of network management |
| Local Interface | 10" touch screen HMI | |
| Sensors and Security | Standard water, smoke, temperature & humidity included, door sensor and electric lock are optional | |
| Video Monitoring | Camera on display screen |