0.02 Class Portable Energy Meter Test System MCST01D
Portable Three Phase Meter Test Equipment MCST01D
Features
- With in-built standard meter class 0.02 and with impulse outputs.
- 7”LCD display
- Can test various of single phase and three phase electromechanical /electronic energy meter
- Can test and display voltage, current, phase, error, active energy, reactive energy, apparent energy, power, phase angle, power factor, frequency and etc
- With in-built error calculator to calculate error of meter under test
- With enough protection, like short-circuit voltage, current open-circuit protection, overload protection, over-voltage protection
- 2-31 times harmonics test, adjustable harmonic amplitude (≤40%)
- Dial test/Start test/Creep test
- RS232 communication port with PC
- Can save test data 500pcs up
- With two impulse inputs, can get connect with external reference when need, work together with internal error processing system of the unit and then comparing error, through also connecting one power meter
- With one option for choice between internal reference meter mode or external reference meter mode.
- Have configuration where you can set the pulse value like pulse/wh or wh/pulse or pulse/kwh or kwh/pulse
Technical Index
Accuracy class: 0.02
Voltage range: 30-300V (P-N) (480 optional)
Current range: 1mA-60A
Supply Voltage: AC 88-284V, 50/60HZ,
Input Power Consumption: 450W
Ambient Temperature: -10℃-45℃
Influence of auxiliary Voltage: ≤0.005% at 10% Variation
Dimension (approx): 510*600*170mm (main unit)
Material of Enclosure: High strength polypropylene composite resin
Frequency Range & Resolution: 45-69HZ, 0.001HZ
Phase Angle Range & Resolution: 0-359.99°, 0.001°
Phase angle Error: 0.03°
Communication Interface: RS232
Voltage Source
Voltage Range: 30-300V (P-N)/51V-520V(P-P);
0-125% continuously adjustable, maximum voltage can be up to 375V (P-N)/650V(P-P)
Resolution: 0.001 - 0.0001V
Output Accuracy: 0.05%
Output capacity: 50VA/phase
Distortion Factor: ≤0.5%
Output Stability: 0.02%/3min
Load Regulation (0-100% load): 0.02%
Current Source
Current range: 1mA –100A, 120% adjustable, maximum up to 120A
Resolution: 0.0001 - 0.00001A
Output Accuracy: 0.05%
Output capacity: 100VA/Phase
Distortion Factor: ≤0.5%
Output Stability: 0.02% / 3min
Load Regulation (0-100% load): 0.02%
Generation Of Harmonics
Fundamental Frequency Range: 45-69HZ
Harmonics test: 2-31times
| Sum of Harmonics | Content of harmonics |
| 2-8 times | 40% |
| 9-15times | 30% |
| 16-31times | 20% |
Phase shift (basic Waveform/Harmonic): 0-360°
Configuration & Accessories List
| Item | Quantity |
| Main unit | 1 |
| Voltage cable | 1 set |
| Current cable | 1 set |
| Optical sensor | 1 Nos |
| Communication cable | 1 |
| Power cord | 1 |
| User manual | 1 |
| PC software (CD) | 1 |
Get in Touch