DC Vacuum Pump Diaphragm DC Pump Pressure -450mmHg 2L/M

 

  • Operating condition
Test Environment Ambient temperature of 20℃ and relative humidity of 65%RH.
Position Horizontal
Load Air pressure 300mmHg
Operating condition 5℃~45℃, RH 30%~85%
Storage condition -20℃~60℃, RH 30%~85%
  • Performance
Rated voltage 3.70VDC
Operating voltage 3.0 - 4.5 VDC
Rated current

<650 mA;The highest current is less than 650mA while

pressurizing with DC3.7V from 0 to 300mmHg

Inflation time At DC3.7V to pressurize in a 100cc tank from 0 to 200 mmHg, Inflation time 6 seconds.
Air flow At DC3.7V ,the air flow is more than 2.0L/min with no load..
Max pressure The maximum pressure value shall be more than 400mmHg while pressurizing with DC 3.7 V tank from 0 till dead-head pressure value
Max vacuum The maximum vacuum value shall be Less than-450mmHg while pressurizing with DC 3.7V tank from 0 till dead-head vocuum value.
Noise Putting a 5 cm sponge under the pump,and placing it about 30 cm away from the noise meter,The evaluated noise level shall be less then 60dB while pressurizing with DC 3.7V from 0 to 200mmHg.
  • Environmental Tests
Low-temperature characteristic Putting the pump in the temperature at negative 20℃ for 72 hours;then taking it out and putting it in a room temperature at 20± 5℃ for 2 hours,Under this circumstance,running through performance test and finding out that the pump still performs well.
High-temperature characteristic Putting the pump in the temperature at 60℃ for 72 hours; then taking it out and putting it in a room temperature at 20 ± 5 ℃ for 2 hours,Under this circumstance,running through perforamance and finding out that the pump still performs well.
High-temperature & High humidity Putting the pump in the temperature at 60℃ and the humidity at 95% for 72 hours;then taking it out and putting it in a room temperature at 20 ± 5 ℃ for 2 hours.Under this circumstance,running through performance test and finding out that the pump still performs well.
Temperature & humidity cycle test After doing the temperature and humidity cycle test,-20℃* 2Hr → +25℃* 1Hr→ +60℃ 85%RH* 2Hr →+25℃*1Hr,for twelve times,the pump shall still perform the same functions proved by running through performance test.
Life test

In a 500CC tank,pressurizing for 10 seconds , stopping for 2

seconds,exhaust for 5 seconds is as one cycle,Doing it for 30,000

times, then examine the pump by testing performance and figure out than the pump is still in a good function.

  • Others
The lead tension

Hanging a 0.5 Kg static load on the terminal of the pump will

not cause a damage on the pump

Solder requirements

Motor terminal for Soldering process the heat temp. is controlled

by 330℃,and operating time is for 3 sec only.

Appearance

The appearances of the pump shall not contain cracks and

impurities.

Fall test

Basic performance and the structure shall not be defected after

following test; With a standard packaging conditions,then dropping it at the front,side,and edges part from the height of 50 cm to the concrete floor.

Unusual test

There is no burning and smoking occurrence while the power is

on with DC4.5V for 8 hours continuously.

 

Drawing:

 

 

 

Application: Portable suction pump

 

 

 

 



 


 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangdong Zhaoli Motor Group Co.,Ltd
Location No. 10, Fuju Street, Fusha Town, Zhongshan, Guangdong, China 528434
Contact Person Christine

Request A Quote

Please check your email address.
Your message must be at least 20 characters.