Micro Flow Flue Gas Analyzer 2um Filter Element 220V 330W SO2 NO CO CO2 O2 Measurement
Boiler Emission Monitoring System(Basic Rev.)
It adopts international leading UV DOAS technology, NDIR technology and long-life ECD technology, and is equipped with an integrated and automatic sampling pretreatment unit and control unit, Gasboard-9081 is suitable to simultaneously measure NO, SO2,O2, O2, CO and CO2 concentration in flue gas. It is an on-line monitoring device dedicated to boiler emission and energy efficiency control, which meets the emission regulatory requirements of national and local environmental protection departments.
• Built-in heated filter, prevent sampling loss.
• Max working temperature 200℃.
• Smart design, safe and reliable.
• Filter element: 2 um
• Length: 3m
• Power supply: 220V
• Power consumption: 330W
• environmental temperature: -40℃—140℃
Gas analyzer features:
• Innovative micro-flow NDIR technology.
• Measure SO2, NO,CO,CO2,O2 and optional temperature, pressure and flow.
• Less interference of H2O for SO2 and NO measurement.
• Built-in zero pump and auto zero calibration with fresh air.
• Optional printer.
• Calculation of Lambda and combustion efficiency.
• Touch screen.
• USB output.
Gas conditioning system features:
• Efficient peltier dehumidifiers for humidity measurement of low concentrations.
• PID temperature control.
• Needle valve flow control.
• Built-in sampling pump and peristaltic pump.
| General Parameter | |
| Measurement | SO2, NO, CO, CO2, O2 |
| Technology | SO2, NO, CO, CO2 (Micro-flow NDIR) |
| Range | O2 (Electrochemical) |
| SO2: 0-2000ppm | |
| NO: 0-2000ppm | |
| CO: 0-5000ppm | |
| CO2: 0-25% | |
| O2: 0-25% | |
| (Note: measurement range can be customized.) | |
| Resolution | SO2, NO, CO: 1ppm |
| CO2, O2: 0.01% | |
| Precision | SO2, NO, CO, CO2, ≤±2% |
| O2≤±3% | |
| Repeatability | SO2, NO, CO, CO2, O2 ≤±1% |
| Zero/Span drift | SO2, NO, CO, CO2≤±2% |
| O2≤±3% | |
| Response time (T90) | <10s (NDIR) |
| Warm-up time | 30 minutes |
| Communication Interface | RS232|Work temperature |
| Relaive humidity | 5-85% |
| Ambient prestsure | 86-108kPa |
| Power supply | AC 220V 50Hz±1Hz |
Combustion and emission control research or certification of Continuous Emission Monitoring System (CEMS), combustion efficiency monitoring for various industrial furnaces or refuse incinerator and boiler.
Q: What is your terms of payment ?
A: We accept trade assurance, western union ,Visa master card and tt.
Trade assurance can protect you, when you confirm the product then the money into my account.
Q: When do you reply to messages?
A: We will reply you for your inquiry in 24 hours.
Q: What is the warranty for your product ?
A: Warranty: 12 months, Lifetime maintenance
Q: When do you send the products? And how do you send it ?
A: For the small order, we will send out the goods with 5 days,If have stock ,we will send immediately.
We send them by ups, fedex, tnt or dhl. For big order, normal is 20 days will finish.
Q: Do you accept OEM or revised logo, color, model, size?
A:Yes, we accept OEM for the qualify buyer.We can make the products according to customer personal requirement.
Q: How about the quality of the managements ?
A: We have a complete quality control system , all of our products will be fully pre-inspection by QC departments before shipping to you . We have the certification of ISO,CE we could send the certification test of our company to you.
Q: How about your after-sale service?
A: After sending, we will track the products for you , until you get the products.
When you got the goods, test them, and give me a feedback.
If you have any questions about the problem, contact with us, we will offer the solve way for you.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.