Ardiology ICU Troponin I Rapid Test Kit D-Dimer One Step Rapid Test
D-Dimer Detection Reagent(D-Dimer)(Immunofluorescence Chromatography) Clinical Comparison In ICU
D-dimer Overview
D-dimer (D-dimer) is an important marker associated with acute thrombus, and its elevation reflects the increased coagulation and cellulose lytic activity in vivo. It not only reflects the presence or continuous formation of thrombus in vivo, but also reflects the enhancement of cellulose dissolution activity in vivo. D-dimer in cellulose cracking products can reflect thrombolytic activity after thrombus formation, which is very important for the diagnosis and treatment of clinical thrombotic diseases.
D-dimer is derived from the cross-linked fibrin clot dissolved by fibrinolytic enzyme, which mainly reflects the fibrinolytic function. The clinical detection of D-dimer is mainly used in the diagnosis of venous thromboembolism (VTE), deep venous thrombosis (DVT) and pulmonary embolism (PE)
D-dimer Performance Index
| Detection range | sample size | Sample type | Test time |
| 0.1~10mg/L | 60μl | Whole blood / plasma | 5min |
D-dimer Clinical Significance
- Screening for seeding intravascular coagulation (DIC)
- Deep vein thrombosis (DVT) examination
- Pulmonary embolism (PE) test
- Diagnosis and evaluation of liver disease and malignant tumor
- Diagnosis of cardiovascular diseases
- Application to surgical patients
- Monitoring and evaluation of thrombolytic drug therapy
| Acute thrombus forms in the circulatory system | ||
| vein | artery | Microvascular circulation |
|
Deep vein thrombosis (DVT) |
Acute coronary syndrome (ACS) apoplexy |
Disseminated intravascular coagulation (DIC) |
D-dimer Normal reference range
The range of normal values of different reagents is different, generally <0.3mg/L or <0.5mg/L.
Application Department
Laboratory, cardiology, ICU, emergency department, pediatrics, operating room
D-dimer Clinical Comparison
| Outpatient with venous thromboembolism | |||
| Clinical preassessment | |||
| Low/moderately suspicious | Highly suspicious | ||
| D-Dimer<0.5mg/L | D-Dimer≧0.5mg/L | ||
| Thromboembolism was excluded | Thromboembolism is recommended and requires further testing | ||
| Do not need treatment | Clinical auxiliary examination | ||
| No thrombosis | thrombosis | ||
| Do not need treatment | treatment | ||
Company profile




Zhongxiu Science And Technology Co.,Ltd., is a high-tech enterprise engaged in the research and development, production and operation of in vitro diagnostic products. The in vitro diagnostic products developed by the company cover POCT series, microbial series, biochemical series and immune series reagents and supporting instruments.
The company has always adhered to the core concept of "fast and accurate, living up to life", committed to providing society with excellent products and services, and contributing to the cause of human health.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.