Industrial Power Supply 960W 24V 40A DIN-Rail AC/DC Converter For Harsh Use CE UL Listed
24V 40A Industrial DIN-Rail Power Supply
Key Feature
- Universal 180 - 264VAC or 254 - 370VDC Input voltage
- Accepts AC or DC input (dual-use of same terminal)
- Operating ambient temperature range: -40℃ to +85℃
- Efficiency up to 95%
- 130% peak load
- Supports 3+1 parallel to increase power and current sharing
- Active PFC, PF>0.95
- DC OK function
- Double-sided conformal coating
- Operating altitude up to 5000m
- 3 years warranty
- Output short circuit, over-current, over-voltage, over-temperature protection
- Safety according to IEC/UL62368, UL508, GB4943
Specification
|
Input |
|||||
|
Item |
Operating Conditions |
Min. |
Typ. |
Max. |
Unit |
|
Input Voltage Range |
Rated input (Certified voltage) |
200 |
|
240 |
VAC |
|
AC input |
180 |
|
264 |
VAC |
|
|
DC input |
254 |
|
370 |
VDC |
|
|
Input Voltage Frequency |
Rated input (Certified voltage) |
50 |
|
60 |
Hz |
|
AC input |
47 |
|
63 |
||
|
Input Current |
Rated input (Certified voltage) |
|
|
6 |
A |
|
230VAC |
|
|
6 |
||
|
Inrush Current |
230VAC(Cold Start) |
|
|
50 |
|
|
Power Factor |
230VAC |
0.95 |
|
|
|
|
Start-up Delay Time |
230VAC, rated load |
|
1000 |
|
Ms |
|
Input Fuse |
Built-in fuse |
|
10 |
|
A |
|
Hot Plug |
|
Unavailable |
|||
|
Output |
|||||
|
Item |
Operating Conditions |
Min. |
Typ. |
Max. |
Unit |
|
Output Voltage Accuracy |
Full load range
|
|
±1.0 |
|
% |
|
Line Regulation |
Rated load |
|
±0.5 |
|
|
|
Load Regulation |
0% - 100% load |
|
±1.0 |
|
|
|
Minimum Load |
|
0 |
|
|
|
|
Stand-by Power Consumption |
|
|
9 |
|
W |
|
Ripple & Noise |
20MHz bandwidth (peak-to-peak value) |
|
|
180 |
mV |
|
Temperature Coefficient |
|
|
±0.03 |
|
%/℃ |
|
Minimum Load |
|
0 |
|
|
% |
|
Hold-up Time |
230VAC, rated load |
|
20 |
|
ms |
|
DC OK Signal |
Resistive load |
30VDC/7A Max. |
|||
|
Short Circuit Protection |
|
Hiccup mode, constant current works 3s(Typ.), turn off 17s(Typ.), continuous, self-recover |
|||
|
Over-current Protection |
230VAC, rated load Normal temperature or high temperature |
110% -140% Io, hiccup, self-recover
|
|||
|
230VAC, rated load low temperature |
≥110% full load after derating, hiccup, self-recover |
||||
|
Over-voltage Protection |
24V |
≤35VDC(Hiccup or clamping, self-recover) |
|||
|
Over-temperature Protection |
230VAC, rated load |
Output-off, self-recover |
|||
|
General |
|||||||
|
Item |
Operating Conditions |
Min. |
Typ. |
Max. |
Unit |
||
|
Isolation Test
|
Input- |
Electric strength test for 1min. leakage current <10mA |
2000 |
|
|
VAC |
|
|
Input-Output |
4000 |
|
|
||||
|
Output- |
500 |
|
|
||||
|
Insulation Resistance |
Input- |
At 500VDC
|
100 |
|
|
MΩ
|
|
|
Input-Output |
100 |
|
|
||||
|
Output- |
100 |
|
|
||||
|
Operating Temperature |
|
-40 |
|
+85 |
℃ |
||
|
Storage Temperature |
|
-40 |
|
+85 |
|||
|
Storage Humidity |
Non-condensing |
10 |
|
95 |
%RH |
||
|
Operating Humidity |
10 |
|
90 |
||||
|
Switching Frequency |
PFC |
55 |
|
75 |
kHz |
||
|
DC-DC |
50 |
|
80 |
||||
|
Auxiliary source |
|
65 |
|
||||
|
Power Derating |
Operating temperature derating |
-40℃ to -30℃ |
4 |
|
|
%/℃ |
|
|
+50℃ to+70℃ |
2 |
|
|
|
|||
|
+70℃ to +85℃ |
3 |
|
|
|
|||
|
Input voltage derating |
180VAC-200VAC |
0.5 |
|
|
%/VAC |
||
|
Leakage Current |
264VAC, 60Hz, touch Current |
<0.5mA |
|||||
|
264VAC, 60Hz, Earth leakage current |
<5mA
|
||||||
|
Safety Standard |
|
EN62368-1, BS EN62368-1 (Report) Design refer to UL61010-1, IEC/UL62368-1, UL508, GB4943.1 |
|||||
|
Safety Class |
|
CLASSI |
|||||
|
MTBF |
MIL-HDBK-217F@25℃ |
>250,000h |
|||||
|
Warranty |
Ambient temperature: <50℃ |
3 years |
|||||
Introduction
IM-DAC220/DC24V40A converts AC220V to DC24V for industrial automation or industrial control system featuring
- cost-effective
- energy efficient
- standard DIN-rail mounting
With good EMC performance, immunity to noise and reliability, it could ensure stable and continuous operation of the automation system
Mechanical Information
|
Mechanical |
|
|
Case Material |
Metal (AL5052, SPCC) |
|
Dimension |
110.00mm × 124.00mm × 127.00mm |
|
Weight |
1680g(Typ.) |
|
Cooling Method |
Air cooling |
|
Electromagnetic Compatibility |
|||
|
Emissions |
CE |
CISPR32 EN55032 150K - 30MHz |
CLASS B |
|
RE |
CISPR32 EN55032 30MHz - 1GHz |
CLASS B |
|
|
Harmonic current |
IEC/EN61000-3-2 |
CLASS A and D |
|
|
Voltage flicker |
EN61000-3-3 |
|
|
|
Immunity |
ESD |
IEC/EN61000-4-2 Contact1±4KV/Air ±8KV |
perf. Criteria A |
|
RS |
IEC/EN61000-4-3 10V/m |
||
|
EFT |
IEC/EN61000-4-4 ±4KV |
||
|
Surge |
IEC/EN61000-4-5 line to line ±2KV/line to ground ±4KV |
||
|
MS |
IEC/EN61000-4-8 30A/m |
||
|
CS |
IEC/EN61000-4-6 0.15 - 80MHz 10Vr.m.s |
||
|
Voltage dips IEC/EN61000-4-11 |
0% of 200Vac, 0Vac, 20ms |
perf. Criteria C |
|
|
40% of 200Vac, 80Vac, 200ms |
perf. Criteria C |
||
|
70% of 200Vac, 140Vac, 500ms |
perf. Criteria A |
||
Characteristic Curve
Note
1. All curves are for 24V output, measured at input 230VAC, 50Hz, output Io, ambient temperature 25℃, unless otherwise stated
2. With an AC input voltage between 180-200VAC and a DC input between 254-282VDC the output power must be derated as per the temperature derating curves
3. This product is suitable for applications using natural air cooling
Ordering Options
|
IM-DAC220/DC12V1.67A |
AC220V to DC12V1.67A, 20W, Din Rail Mounted, -30℃~70℃ |
|
IM-DAC220/DC24V1A |
AC220V to DC24V1A, 24W, Din Rail Mounted, -30℃~70℃ |
|
IM-DAC220/DC48V2.5A |
AC220V to DC48V2.5A, 120W, Din Rail Mounted, -40℃~70℃ |
|
IM-DAC220/DC48V5A |
AC220V to DC48V5A, 240W, Din Rail Mounted, -40℃~70℃ |
|
IM-DAC220/DC48V10A |
AC220V to DC48V10A, 480W, Din Rail Mounted, -40℃~70℃ |
|
IM-DAC220/DC48V20A |
AC220V to DC48V20A, 960W, Din Rail Mounted, -40℃~85℃ |