Chemical Acrylic Vacuum Glove Box B Type 2 Ports Helium Gas
Chemical Acrylic Vacuum Glove Box B Type 2 Ports Helium Gas
Product Introduction
Some materials are very sensitive to water and oxygen when doing chemical experiment. So it is hard to finish the research. Although vacuum vessel can satisfy anaerobic and vacuum degree, it is not convenient for operating the procedure. Vacuum glove box solve the environment and operation problem.
Applications
Widely used in anaerobic anhydrous dust-free high purifying operating environment in which lithium battery, semi-conductor, super capacitor, special lamp, laser welding, soldering, material composition, OLED, MOCVD and many more processing. Also application in biology such as anaerobe cultivation, cell hypoxic cultivation.
Technical Features
| Transit box vacuum degree | 0~ -0.1Mpa (2.5 Vacuum gauge), pressure maintain period for 12Hours above |
| Operation box vacuum degree | 0~ -0.1Mpa (2.5 Vacuum gauge), pressure maintain period for 12Hours above |
Product Parameters
| Model | Operation Box (mm) | Thickness of Acrylic (mm) | Transit Box (mm) | Vacuum Function |
| YKG-012B | 700*450*500 | 10mm | 240*240*240 | It owns vacuum function for operation box, and no vacuum function for transit box |
| YKG-011B | 800*550*600 | 10mm | 240*240*240 | |
| YKG-010B | 1000*500*500 | 10mm | 240*240*240 | |
| YKG-009B | 1000*700*500 | 10mm | 240*240*240 | |
| YKG-008B | 900*600*700 | 10mm | 240*240*240 | |
| YKG-007B | 1000*600*700 | 10mm | 240*240*240 | |
| YKG-006B | 1000*750*700 | 10mm | 240*240*240 | |
| YKG-005B | 1200*600*600 | 10mm | 240*240*240 | |
| YKG-004B | 1200*600*700 | 10mm | 240*240*240 | |
| YKG-001B | 1094*640*645 | 10mm | 240*240*240 |
Product Features
- Simple structure.
- Highly transparent, resistance for corrosion substance and climate change in normal situation.
- Installed multihole socket for doing experiment easily and conveniently.
- Good airtightness to shield and absorb in α-ray and β-ray to protect people from radiant hurt.
- Inert gas replacement.
Operation Notice
- While under vacuum state, it is not allowed to open door or glove interface cover, not allowed to discharge any part to check and repair
- Please start vacuumizing the glove interface first or vacuum gloves with main box together. And stop vacuumizing main box first or stop vacuumizing main box with gloves together.
- The accessory to connect with vacuum tube should be fit and sealed tightly. It should not exceed 1Pa when filling in inert gas.