UL CuL VDE CQC PSE KC MTS Micro Fuse Radial Lead Slow Blow Square Fuse 250V T1A T2A T3.15A T5A T6.3A Miniature Fuse
Features of UL cuL VDE CQC PSE KC MTS Micro Fuse Radial Lead Slow Blow Square Fuse Miniature Fuse
- Slow blow
- Short and long leads available
- Tape or bulk package available
- Internationally certified
- Compact design
- Solderable or plug-in mounting
- Low internal resistance
- Shock safe casing
- Vibration resistant
- Halogen and lead free
- RoHS compliant
- UL 94V-0 Case
Certifications of MTS Micro Fuse Radial Lead Slow Blow Square Fuse Miniature Fuse
| Agency | Ampere Range | Agency File Number |
| UL | 50mA ~ 20A | E340427 (JDYX2 ) |
| CQC | 50mA ~ 10A |
QQC11012061981
|
| cUL | 50mA ~ 6.3A | E340427(JDYX8) |
| VDE | 50mA ~ 6.3A | 40039420 |
| PSE | 50mA ~ 6.3A | PSE13020693 |
| KC | 50mA ~ 6.3A | SU05045-14001/2/3 |
Electrical Ratings of MTS Micro Fuse Radial Lead Slow Blow Square Fuse Miniature Fuse
|
Part No. |
Ampere Rating |
Voltage Rating |
Max Voltage Drop (mv) |
I2TMelting Integral(A2.S) |
Agency Approvals | ||||||
| UL | TUV | CUL | VDE | CCC | PSE | KC | |||||
| MTS0050A | 50mA | 250V | 1600 | 0.015 | ● | ○ | ● | ○ | ○ | ○ | ○ |
| MTS0063A | 63mA | 250V | 1600 | 0.016 | ● | ○ | ● | ○ | ○ | ○ | ○ |
| MTS0080A | 80mA | 250V | 1500 | 0.017 | ● | ○ | ● | ○ | ○ | ○ | ○ |
| MTS0100A | 100mA | 250V | 1500 | 0.02 | ● | ○ | ● | ○ | ○ | ○ | ○ |
| MTS0125A | 125mA | 250V | 760 | 0.10 | ● | ○ | ● | ○ | ○ | ○ | ○ |
| MTS0160A | 160mA | 250V | 500 | 0.15 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS0200A | 200mA | 250V | 260 | 0.21 | ● | ● | ● | ● | ● | ○ | ● |
| MTS0250A | 250mA | 250V | 240 | 0.48 | ● | ● | ● | ● | ● | ○ | ● |
| MTS0315A | 315mA | 250V | 220 | 0.78 | ● | ● | ● | ● | ● | ○ | ● |
| MTS0400A | 400mA | 250V | 200 | 1.22 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS0500A | 500mA | 250V | 190 | 2.11 | ● | ● | ● | ● | ● | ● | ● |
| MTS0630A | 630mA | 250V | 180 | 2.88 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS0800A | 800mA | 250V | 160 | 3.92 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS1100A | 1A | 250V | 140 | 5.77 | ● | ● | ● | ● | ● | ● | ● |
| MTS1125A | 1.25A | 250V | 130 | 8.34 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS1160A | 1.6A | 250V | 120 | 13.60 | ● | ● | ● | ● | ● | ○ | ● |
| MTS1200A | 2A | 250V | 100 | 26 | ● | ● | ● | ● | ● | ● | ● |
| MTS1250A | 2.5A | 250V | 100 | 42 | ● | ● | ● | ● | ● | ○ | ● |
| MTS1300A | 3A | 250V | 100 | 45 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS1315A | 3.15A | 250V | 100 | 90 | ● | ● | ● | ● | ● | ● | ● |
| MTS1350A | 3.5A | 250V | 100 | 100 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS1400A | 4A | 250V | 100 | 120 | ● | ● | ● | ○ | ○ | ○ | ○ |
| MTS1500A | 5A | 250V | 100 | 170 | ● | ● | ● | ● | ● | ● | ● |
| MTS1630A | 6.3A | 250V | 100 | 290 | ● | ● | ● | ● | ● | ○ | ● |
| MTS1800A | 8A | 250V | 100 | 320 | ○ | ● | ● | ○ | ● | ○ | ○ |
| MTS2100A | 10A | 250V | 95 | 450 | ○ | ● | ● | ○ | ● | ○ | ○ |
Dimension
| NO. | Part Name | Material |
| 1 |
Cap |
Black or Brown Thermoplastic Polyamide PA 6.6, UL 94 V-0 |
| 2 | Base | Black or Brown Thermoplastic Polyamide PA 6.6, UL 94 V-0 |
| 3 | Fuse element | Alloy |
| 4 | Lead wire | Copper, Tin-plated |
Breaking Capacity (35A or 10In, whichever is greater at 250V AC)
| % of Ampere Rating(In) | Blowing Time |
| 150%* In | 60 min Minimum |
| 210%* In | 2 min Max |
| 275%* In | 400 ms~10 s |
| 400%* In | 150 ms~3 s |
| 1000%* In | 20 ms~150 ms |
Package
A. Bulk packing:
Bulk 1000 pcs in per poly bag;
B. Tape packing:
1000 pcs per inner box
Related Micro Fuses
| Series No. | Size | Blow Type | Current Range | Voltage | Color | Approvals |
| MTS | 8*4*8mm | Time-Lag | 50mA~10A | 250V | Black/ |
UL/CUL/PSE/VDE/ KC/TUV/CCC |
| MFS | 8*4*8mm | Quick Acting | 50mA~10A | 250V | Black | UL/CUL/TUV |
| NTS | 8*4*8mm | Time Delay | 50mA~10A | 300V | Black | UL/CUL/TUV/CQC |
| NFS | 8*4*8mm | Fast Blow | 50mA~10A | 300V | Black | UL/CUL/TUV |
| TMS | 8*4*8mm | Slow Blow | 50mA~10A | 350V | Black | UL/CUL/TUV |
| FMS | 8*4*8mm | Fast Acting | 50mA~10A | 350V | Black | UL/CUL/TUV |
Shipping Term:
EXW, DDU, DDP, C&F, FOB
Shipping Methods:
Express, By Air, By Sea
Selection of the Fuse and Holder Solution
The first step is to answer the following questions:
- Will the fuse need to accessible for replacement?
- How often will the fuse need to be replaced?
- Should the end customer of the appliance have access to change the fuse?
- Should the fuse only be accessible from outside the appliance?
- How much is available to spend on safety and reliability?
5.1.2. Requirements and characteristics
The most important standards for fuse-holders, which specify requirements, characteristics and testing methods are:
- IEC-publication 257 (1968) and Amendment no. 2 to this publication dated January 1989.
- UL-standard no. 512.
-
-
Company warehouse
-
Q: Are you trading company or manufacturer ?
A: We are a fuse product factory.
Q: How long is your delivery time?
A: Generally it is 3 days if the goods are in stock, 5-10 days if the goods not in stock, according to the quantity.
Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay for the shipping cost.
Q: What are your terms of payment ?
A: 100% in advance, T/T.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.