Dongguan Haiyuan Water Treatment Co., Ltd.
                                                                                                           
Member Supplier
2015 Years
Since 11
Menu

460V Deionized Water Systems , 50TPH mixed bed dm plant Semi Control

Price Negotiable
Price: 2000-4000
MOQ: Negotiable
Delivery Time: Negotiable
Brand: JISHUI
Product Description

Mixed bed water treament demineralizer mixed bed ion exchanger mixed bed

Please Attention

HY FACTORY OFFER YOU :

1: FACTORY DIRECT PRICE.

2: NICE QUALITY.

3: ONLINE PAYMENT.

4: SUPPORT REFUND AFTER YOUR INSTALLED THE PLANT IF THERE ARE ANY PROBLME.

5: AFTER SALES SERVICES 24/7

6. Letters patent

7. ENGINNER CAN BE OVERSEA INSTALLNATION

We have 2 factories +300 workers+ Qualified engineer+ Engineer Overseas service

Mixed bed water treament demineralizer mixed bed ion exchanger mixed bed 

Process function description

1. Mixed bed use automatic control and semi-control .Pretreatment parts can adopt fiber glass or stainless steel material.

2.Mixed bed ion exchange has protected when no power, poor power, larger electrical current, leakage, short circuit.

3.Ion exchange is compact, easy installation.

4.Mix bed water treatment equipped with manual and auto control based on user needed.

5. Haiyuan demineralizer produce as per ISO and SGS standard and main parts accessories have obtained CE certification.

6. All the ion exchange mixed bed will be commissioning well. Make sure don't have any problem when arrived site. 

7.What we provide not only the good products, but also our whole team, the quality, experience, and service.

 

FEED WATER QUALITY AND TREATMENT TECHNOLOGY OF  MIXED BED

MIXED BED ION EXCHANGE

   Mixed bed ion exchange is an ion exchange process for polishing of demineralised water, meaning for removal of trace dissolved solids from water.

    A mixed bed ion exchanger (also: mixed bed polisher, mixed bed filter) is a vessel filled with a mixture of cation exchange resin and anion exchange resin. During service, water flows through this resin mixture. Cations dissolved in the water are then exchanged for hydrogen ions (H+), while anions dissolved in the water are exchanged for hydroxide ions (OH-). Hydrogen ions and hydroxide ions react to water.

   With increasing service life, the ion exchange resins deplete. Depleted mixed bed resins are regenerated, usually with both hydrochloric acid (HCl) and sodium hydroxide (NaOH). With each regeneration, potentially acidic or alkaline waste water is produced, which may need to be neutralised. In case of smaller mixed bed exchangers, the ion exchange resin is sometimes also discarded and exchanged once depleted, rather than regenerated.

    Usually, a mixed bed ion exchanger is used either as a last polishing step downstream of another demineralisation process, or as a working mixed bed for demineralisation of already partly demineralised or low-TDS water (e.g. condensate).

Process Introduction

Process introduction of mixed bed demineralizer

Process flow of  mix bed water treatment

NOS.

Items

Information

1. mixed bed demineralizer Pre-treatment part

1.1

Sand filter

Remove  turbidity, SS matter, organic matter, colloid, etc.  

1.2

Active carbon filter

Remove color, free chloride, organic matter,

harmful matter, etc.

1.3 

Water softener

Soft water and reduce it's hardness.

2. ion exchange water treatment Deionized water RO part

2.1

High pressure pump

Provide power for RO.

2.2

PP filter

Prevent large particles, iron, dust, SS matter,

impurity into RO membrane. 

2.3

RO membrane

Remves: lead, cooper, barium, chromium, mercury,

sodium, cadmium, fluoride, nitrite, nitrate, and selenium.

3. industrial water treatment Deionized Water System system part

3.1

Ion exchange feed water pump

Provide power for ion exchange system.

3.2

Anion and cation exchange filter

Further removes ions in water.

3.3

Security fitler

Prevent the resin leakage

4. mixed bed demineralizer Electricity control system

4.1

PLC+Touch screen control system

Japan Mitsubishi.siemens

4.2

Electrivity components

Import from German. Schneider, Omron.

4.3

Pipe and fitting

Adopt domestic famous brands.

 
Certifications

 

 

 
Haiyuan workshop

 
Customers photos

 
Buying Guides

Mixed bed water treament demineralizer mixed bed ion exchanger mixed bed Buying Guides

 

To find the most appropriate mixed bed for your use, please have the following information ready

· Product water flow rate ( m3/hr, m3/day, Liter/hr,GPM,GPD etc.)

·· Product water purpose(drinking, irrigation, industry process or others)

· Feed Water TDS (Total dissolved solids). Is it from Borehole/salt/brackish/lake water

· Iron

· Manganese

· TSS(Total Suspended Solid)

· SDI(Silting Density Index)< 3

· Water must be free from oils and grease

· Chlorine must be removed

· Power (110/220/380V/415V/460V, 50 or 60 Hz) 3 phase.

           ·  It is necessary to make water analysis reprot for borehole water,lake water, seawater.

           ·  If soure water is tap water no need end to us TDS or water analysis report.

 

Send your Inquiry Details in the Below, Click "Send" Now!

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Dongguan Haiyuan Water Treatment Co., Ltd.
Location DongGuan,Guangdong,China
Contact Person Eva

Request A Quote

Please check your email address.