FCB430 FCB450 ABB Flow Meter Coriolis Mass Flowmeter CoriolisMaster
Price:
100
MOQ:
1
Delivery Time:
20 days
Brand:
ABB
Product Description
Coriolis mass flowmeter CoriolisMaster FCB430 and FCB450
CoriolisMaster FCB400 series of compact Coriolis mass flowmeters feature low pressure drop, high capacity, intuitive ABB common display, five modular I/O`s and various communication protocols, now with OIML R117 and MID approved.
With no up or downstream piping requirements the compact Coriolis flowmeters can be installed in the tightest spaces, enabling applications not possible before.
| Sensor | ||||
| Model | FCB400 standard design | FCH400 hygienic design | ||
| Chassis | Integral mount design, remote mount design | |||
| Measuring accuracy for liquids | FCB430 | FCB450 | FCH430 | FCH450 |
| Mass flow* | 0.4%.0.25%and 0.2% | 0.1% and 0.15% | 0.4%,0.25% and 0.2% | 0.1% and 0.15% |
| Volume flow* | 0.4%.0.25%and0.2% | 0.15% and0.11% | 0.4%.0.25%and 0.2% | 0.15%and 0.11% |
| Density | 0.01kg/l | 0.002kg/l 0.001kg/l (optional) 0.0004kg/l (optional) |
0.01kg/l | ·0.002kg/l 0.001 kg/l (optional) 0.0004kg/l (optional) |
| Temperature | 1K | 0,5K | 1K | 0,5K |
| Measuring accuracy for gases* | 1% | 0.5% | 1% | 0.5% |
| Permissible measuring medium temperatura Tmedlum |
-50 to 160°C (-58 to 320F) |
-50 to 205°C (-58 to 400F) |
-50 to 160°C (-58 to 320F) |
-50 to 205C (-58 to 400F) |
| Process connection | ||||
| Flange DIN 2501/EN 1092-1 | DN 10 to 200;PN 40 to PN 160 | 一 | ||
| Flange ASME B16.5 | DN 2/1 to 8 in; CL150 to CL1500 | 一 | ||
| jis flange | DN 10 to 200: JIS 10K to 20K | 一 | ||
| Pipe fitting DIN 11851 | DN 10 to 100 (3/8 to 4 in) | DN 20 to 100 (% to 4in) | ||
| Pipe fitting SMS 1145 | DN 25 to 80 (1 to 3in) | 一 | ||
| Tri-clamp DIN 32676(ISO2852) Tri-clamp BPE |
DN 15 to 100 (1/4 to 4in) DN3/8 to 4in |
DN 20 to 100 (%4 to 4in) DNW:to 4in |
||
| Female thread DIN ISO 228 andASME B 120.1 | DN 15;PN100 | 一 | ||
| Other connections | On request | Onrequest | ||
| Wetted material | Stainless steel1.4435 or 1.4404(AISI 316L), nickel alloy C4/C22 | Stainless steel, polished 1.4404 (AISI 316L) or 1.4435(AISI 316L) | ||
| IP rating | Integral mount design: IP 65 / IP 67, NEMA 4X Remote mount design: IP 65 /IP 67/IP 68 (sensor only, immersion depth:5m), NEMA 4X |
|||
| Approvals | ||||
| Explosion protection | ATEX/IECEx/UKEX/cFMus /EAC-Ex | ATEX /IECEx/UKEX/cFMus/EAC-Ex | ||
| Hygiene approvals | 一 | FDA compliant | ||
| Legal metrology | OIML R117, MID, devices for legal metrology in accordance with API /AGA | |||
| Further approvals | At www.abb.com/flow or upon request. | |||
| Indication of accuracy in % of the measured value | ||||
The FCB400 series delivers:
- Up to five modular I/Os
– Multivariable meter design
– Optional plug-in cards
– Automatic firmware update
– Various communication protocols available:
EthernetIP, Modbus TCP, Web Browser and Profinet
- SmartSensor
– All digital solution
– Installation flexibility
– Meter intelligence located in the sensor
- SensorApplicationMemory
– Maximum data security
– Plug and play electronics replacement
- ABB common look and feel
– Easy Set-up
– Operation through the glass via capacitive keys
- VeriMass on-board verification and diagnostics
– Online preventive maintenance
– Extended maintenance cycles
– Reduced maintenance effort
- Designed for 70 °C (158 °F) ambient temperature and high vibrations
- Enhanced Coriolis control (ECC) option for advanced measurement for multiphase conditions and other challenging fluids
- Lower pressure drop
- Self-draining
- Global approvals for explosion protection
- OIML R117 and MID approved
The FCB450 adds:
- DensiMass software for direct concentration measurement
- FillMass software for filling application control
- OIML R117; MID approved
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2
– NEPSI Zone 0/1/2
– Various other approvals
– OIML R117; MID approved - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB430
– Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
– Density: 10 g/l
FCB450
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 0.002 kg/m³ or 0.001kg/m³ needs to extend to 0.0004 kg/m³ - Measuring medium temperature
FCB430
– -50 to 160 °C (-58 to 320 °F)
FCB450
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 5 modular I/Os
– HART 7.1
– PROFIBUS DP
– Modbus
– Ethernet- Ethernet IP
- Modbus TCP
- Webserver
- More protocols in preparation
- Power supply
– 11 to 30 V DC, 110/230 V AC
– Power over Ethernet
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Eco-Tech Suzhou Limited
Location
Room 101, Building 19, No. 4388 Dong Shan Avenue, Lin hu Town, Wu Zhong District, Suzhou, China zip 215106
Contact Person
Melissa