Indoor IP40 Mini Circuit Breaker SB6H 3P,4P 10KA MCB

 

Instantaneous tripping characteristic:

Circuit breaker SB6 are designed for protection of distribution and branch circuits, having different load;

♦ Curve B----Device should not work in 0.1 second at current 3 In; at current 5 In should work in less than 0.1S

♦ Curve C---- Device should not work in 0.1 second at current 5 In; at current 10 In should work in less than 0.1S

♦ Curve D---- Device should not work in 0.1 second at current 10 In; at current 20 In should work in less than 0.1S

 

Specifications:

Poles 1P,1P+N, 2P, 3P, 3P+N, 4P
Electrical specification
Rated current(A) In 1-63
Rated frequency(Hz) 50/60
Rated working voltage(V) Ue 1P:230/400~, 2/3/4P: 400~
Rated insulated voltage(V) Ui 500
Impulse withstand voltage(KV) Uimp 6
Rated short-circuit breaking capacity(KA) Icn

 

4.5

Instantaneous tripping type B,C,D
Maximum working voltage Umax 440
Minimum working voltage Umin 12
Dielectric test voltage (kv) 2
Service life Mechanical standard value 10000
(O-C) Electrical Standard value 4000
Control and indication:
Shunt release (SHT) Optional
Undervoltage release(UVT) Optional
Auxiliary contact(AUX) Optional
Alarm contact(ALT) Optional
Contact position indicator Default
Fault indication None
Connection and installation:
Ambient temperature (with daily average≤35℃) -5℃~+40℃
Protection degree All sides IP40
Connection terminal IP20
Wire(㎟) 16
Busbar(㎟) 16
Mounting Cable/Busbar
Pollution degree 2
Reference temperature for setting of thermal element(℃) 30
Storage temperature(℃) -25℃~+70℃
Tightening torque 3.0
Connection Top and Bottom
Dimensions(mm) a(1P/2P/3P/4P) 17.5/35/52.5/70
b(1P/2P/3P/4P) 83/83/83/83
(WxHxL) c(1P/2P/3P/4P) 67/67/67/67

 

Application:

 

The Indoor Mini Circuit Breaker Can be used for: Short-circuit protection, Isolation function, Overload protection, Indication function of contact position, 35mm Din-rail installation, top incoming and bottom outgoing wiring type, or bottom incoming and top outgoing wiring type, able to select electrical accessories and achieve distant indication of MCB condition; breaking, closed, and fault tripping and select electrical accessories and realize under-voltage and over-voltage protection of MCB and distant shunt release

 

 

 Over-current operating characteristics:

No. Rated current of release (A) Initial state Test current Specified time Result to be obtained Remarks
1 1~63 code state 1.13 In t ≤ 1h Non-trip  
2 1~63 upon the previous test 1.45 In t < 1h trip setting current up to specified value steadily in 5s
3 In ≤ 32 code state 2.55 In 1s <t <60s trip  
In > 32 code state 2.55 In 1s <t <120s trip  
4 1~63 code state 3 In t ≤0.1s Non-trip B type
1~63 code state 5 In t <0.1s trip B type
1~63 code state 5 In t ≤0.1s Non-trip C type
1~63 code state 10 In t <0.1s trip C type
1~63 code state 10 In t ≤0.1s Non-trip D type
1~63 code state 20 In t <0.1s trip D type

 

 

The Number of Poles:

 

Dimensions:

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company YueQing ZEYI Electrical Co., Ltd.
Location Sifang Industrial Park, Beibaixiang Town, YueQing Wenzhou Zhejiang Province China
Contact Person Saniya

Request A Quote

Please check your email address.
Your message must be at least 20 characters.