MPPT VFD Solar Pump Inverter for Irrigation System with 99.9999% MPPT efficiency

Price Negotiable
Price: Negotiable
MOQ: 5
Delivery Time: depend on the order quantity
Brand: VEIKONG
Product Description

Solar mppt inverter for irrigation system solar pump 220v 380v 2.2kw 4kw

 
VEIKONG specialize in solar pump inverter, industrial vfd, soft starter manufactureing.
 
 
Main Features: ( Power range: 0.75kw-75kw 220v, 0.75kw-250kw 380v)
 

1. Operates without grid directly from photovoltaic (PV) cells

 

2. Automatic start and stop with solar radiation

 

3. Built-in maximum power point tracking (MPPT)

 

4. Easy installation and set-up for serial production

 

5. Compatible with all pump types

 

6. Good ROI (Return on Investment) against diesel powered pumping

 

7. Compact and uniform drive module design (IP20)

 

8. Dual supply capability with change over switch - solar and grid compatible

 

9. Sensorless vector control of induction motors and permanent magnet motors

 

 

 

Accessories:

 

1. GPRS (support 2g/3g/4g internet)

 

It supplies water volume monitoring and operation of inverter from anywhere at anytim

It’s convenient to visit real time and historical data via web or Android APP anytime and anywhere.

This easy-to-use platform makes monitoring of solar pump systems simple and convenient,

far reducing operate time and monitoring costs as well.

 

 

2. LCD keypad

 

Standard inverter are with LED keypad,LCD keypad is optional.

LCD keypad can monitor 4 parameters at the same time. LED keypad show one parameter only.

LCD keypad with detailed parameter explain,no need use user manual ,more user friendly.

LCD keypad with copy and update and download function.widely used for government projects and big farms.

 


 

Product Application:
 

 

Model Range
 

Drive Model Related Voltage Max DC input voltage (V) Rated output current (A) Applicable water pump (KW) SIZE
VFD500M-20T00150-PV 220V 800 7 1.5 SIZE A
VFD500M-20T00220-PV 220V 800 10.6 2.2 SIZE A
VFD500M-40T00150-PV 380V 800 4.2 1.5 SIZE A
VFD500M-40T00220-PV 380V 800 6 2.2 SIZE A
VFD500-20T00150-PV 220V 800 7 1.5 SIZE A
VFD500-20T00220-PV 220V 800 10.6 2.2 SIZE A
VFD500-20T00400-PV 220V 800 17 4 SIZE A
VFD500-40T00150-PV 380V 800 4.2 1.5 SIZE A
VFD500-40T00220-PV 380V 800 6 2.2 SIZE A
VFD500-40T00400-PV 380V 800 9.4 4 SIZE A
VFD500-40T00550-PV 380V 800 13 5.5 SIZE B
VFD500-40T00750-PV 380V 800 17 7.5 SIZE B
VFD500-40T01100-PV 380V 800 25 11 SIZE C
VFD500-40T01500-PV 380V 800 32 15 SIZE C
VFD500-40T01850-PV 380V 800 38 18.5 SIZE D
VFD500-40T02200-PV 380V 800 46 22 SIZE D
VFD500-40T03000-PV 380V 800 60 30 SIZE E
VFD500-40T03700-PV 380V 800 75 37 SIZE E
VFD500-40T04500-PV 380V 800 96 45 SIZE F
VFD500-40T05500-PV 380V 800 112 55 SIZE F
VFD500-40T07500-PV 380V 800 150 75 SIZE G
VFD500-40T09000-PV 380V 800 176 90 SIZE G
VFD500-40T11000-PV 380V 800 210 110 SIZE H
VFD500-40T13200-PV 380V 800 253 132 SIZE I
VFD500-40T16000-PV 380V 800 304 160 SIZE I
VFD500-40T18500-PV 380V 800 340 185 SIZE J
VFD500-40T20000-PV 380V 800 377 200 SIZE J

 

 

Use level probe in the well for protection against dry running

1st solution: See self learning of dry run

2nd solution: do it manually Set P24.13=30%-60%(as per real empty load current percentage based on rated current) and P24.14 P24.16 and P23.21

3rd solution: If your sensor is digital switch ,just short D4 and com

4th solution:If your float signal is Analog signal, Connect Ai2 and 10V and GND and set P41.00=23 and

P41.03-P41.06

 

How to set minimum frequency ( for example) 30hz and maximum 50HZ

Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07

 

If pump is 60HZ frequency, how to set max frequency?

Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.

Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32

 

How to check and solve basic problem of inverter trips and error

a:Check the total vmp and voc of solar panels ,solar panel technical data

b:Check motor pump power and rated current

c: Check the distance between motor and inverter

d: Check trip record r25.00 r25.01 25.02 25.03 r26.00 r26.01 r26.02 r26.03

e: Check troubleshooting fault and find relevant solutions

f : Check if motor insulation has been damaged or motor is blocked

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen Veikong Electric Co., Ltd.
Location 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China
Contact Person Terry

Request A Quote

Please check your email address.
Your message must be at least 20 characters.