Product Overview
Fire fan control cabinet fire electrical control device KH-FS series (hereinafter referred to as the device) is our company fully investigate the market demand, summarize years of engineering experience, integrate the standard"GB16806-2006 Fire linkage control System" requirements and spirit, launched products.
The device is used for the control of 15KW fire pump. The device is mainly composed of double power switch, automatic switch, AC contactor and motor protector, which can meet the requirements of short circuit and overload protection of the motor and ensure the reliable operation of the motor. Ambient temperature: -5℃ ~ +40℃; Relative humidity ≤95%, do not condense in the environment. And without any environmental pollution.
| Product Name |
Fire Fan Distribution Box |
Box Size | 300x400x160mm |
| Product Power | 0.75-18.5KW | Box Thickness | 0.8mm |
| Rated Voltage | AC380V | Install | Wall-hanging |
| Clap Voltage | AC220V | Quality Assurance Service | One year |
| Description of Characteristics | It can be used to control the direct start, stop of various water pumps, motors, and fans, and with local control or remote fire control.With short circuit, overload protection, fire valve connection point, fire emergency control, fire DC24V strong start, operation feedback, fault feedback. | ||
Function Description:
1. The fire electrical control device has manual and automatic control mode and can accept the linkage control signal from the fire linkage controller. Under the automatic working state, the scheduled action can be executed to control the controlled equipment into the working state.
2. Fire electrical control device can be allocated to start device, accept to start the action signals of the device and will start the action signals sent to the fire linkage controller device, in the automatic fire control the working state of electric control device after receives the boot device action, the scheduled action, control the controlled device.
3. The fire electrical control device can manually control the controlled equipment into the working state. In the automatic working state, manual insertion control is preferred.
4. The fire electrical control device can accept the working state information of the controlled equipment and transmit the signal to the fire linkage controller.
5. The fire electrical control device powered by three-phase AC power supply can send out fault sound and light signal when the power supply is out of phase and out of phase. At the same time, the fire electrical control device does not make the controlled equipment produce misaction when the power is out of phase and out of phase.
Product details:
- components: schneider, ABB, Chint and other domestic and foreign first-line brands to ensure high quality products.
- cabinet: cabinet with protection grade, after strict phosphating process to ensure the quality of the cabinet; Organic glass double door design, double quality assurance.
- Door lock: special custom lock.
- color and appearance: selected industrial gray RAL7035 plastic sprayed, beautiful industrial sense.
Advantages:
1. Anti-interference: separate the main line and the secondary loop to avoid signal interference.
2. The ground cable is safe and reliable: the cabinet door plate is reliably connected to the floor bar.
3. Reliable wire connection: the joint is pressed with special copper head and electric screwdriver and button saw.
4. Special terminal connection: automatic control system special terminal, isolation rust, safe and reliable.
5. Clear comparison between the drawing and the product: the unique electrical symbol line number of the component sticker is printed uniformly and consistent with the drawing, which is convenient for future debugging and maintenance.
6. Perfect wiring process: the wiring specification is neat.
Internal details:
- Integrated operation panel
- Chint circuit breaker
- Copper wire
- Integrated wiring bar
- Chint contactor
- Chint thermal relay
Details:
- A shell lends itself to simple and atmospheric appearance
Cabinet body uses high strength cold roll board, face plate ply 1.0mm, flank 1.2mm, cabinet face uses paint that bake, spray model, polishing burnish craft, make cabinet body beautiful and easy, resist pressure wear-resisting.
- Link to the system automatically: The fire signal alarms
Ac contactor straight start, manual and automatic operation to perform reservation action, feedback signal of exhaust fan
Product features:
1. Waterproof, dustproof, anti-corrosion
2. Surface spray (paint, polishing) process
3. Stable performance, safe and efficient
4. Long service life
Pressure resistance of MAX Thickening cold rolled steel plate
Cold rolling casting process, door thickness of 10mm, 0.8mm thick box, with good compressive resistance and bearing capacity.
Environmental applications
Multiple applications
- The pump control
- Motor control
- The fan control
Every detail was carefully polished
- Rectilinear miniature circuit breaker
Ms break is more suitable for motor use
- Fault an AC contactor
Galaxy gold contact 32 pieces of silicon steel core to carry more current
- Harmonic terminal
Clear, easy to understand, safe and reliable
- Virtual Gateway Intelligent Controller
Beautiful and standardized production
- User-friendly control of the system
The layout is reasonable, easy to operate, intuitive and clear
Get in Touch