TBBX Low Voltage Local Reactive Power Compensator 1-100Kvar 400V
TBBX Low Voltage Power Factor Correction Without Power In Local Compensation Device
Application
TBBX type high voltage reactive local compensating device (hereinafter call compensating device) is of indoor use, for rated voltage 6-10KV, 50Hz, system to locally compensate reactive power for 6-10KV 3-P AC motor and to lessen the electric loss, improve electric quality and motor starting performance, the compensating device will be switched on/off along with the motor on/off. The effect is better than the central compensation.
Main technical data:
The basic parameters in situ compensator
| No. | Type | Rated voltage(kV) | Rated capacity of capacitor group(Kvar) |
Rated current of capacitor group (A) |
Protection mode | Shunt capacitor model |
| 1 | TBBX6-90-3N | 6.6 | 90 | 7.9 |
Each capacitor unit has fuse protection |
BFM6.6//3-30-1 |
| 2 | TBBX6-120-3N | 12 | 10.5 | BFM6.6//3-40-1 | ||
| 3 | TBBX6-150-3N | 150 | 13.1 | BFM6.6/3-50-1 | ||
| 4 | TBBX6-180-3N | 180 | 15.75 | BFM6.6/3-60-1 | ||
| 5 | TBBX6-200-3N | 200 | 17.5 | BFM6.6/6-200-3 | ||
| 6 | TBBX6-240-3N | 240 | 21 | BFM6.6/6-80-3 | ||
| 7 | TBBX6-300-3N | 300 | 26.2 | BFM6.6//3-100-1 | ||
| 8 | TBBX6-360-3N | 360 | 31.5 | BFM6.6//3-120-1 | ||
| 9 | TBBX6-450-3N | 450 | 39.4 | BFM6.6//3-150-1 | ||
| 10 | TBBX6-600-3N | 600 | 52.5 | BFM6.6//3-200-1 | ||
| 11 | TBBX10-90-3N | 10 | 90 | 4.7 | BFM11/3-30-1 | |
| 12 | TBBX10-120-3N | 120 | 6.3 | BFM11/3-40-1 | ||
| 13 | TBBX10-150-3N | 150 | 7.9 | BFM11/3-50-1 | ||
| 14 | TBBX10-180-3N | 180 | 9.45 | BFM11//3-60-1 | ||
| 15 | TBBX10-200-3N | 200 | 10.5 | BFM11-200-2 | ||
| 16 | TBBX10-240-3N | 240 | 2.6 | BFM11-80-3 | ||
| 17 | TBBX10-300-3N | 300 | 15.75 | BFM11/3-100-1 | ||
| 18 | TBBX10-360-3N | 360 | 18.9 | BFM11//3-120-1 | ||
| 19 | TBBX10-450-3N | 450 | 23.6 | BFM11//3-150-1 | ||
| 20 | TBBX10-600-3N | 600 | 31.5 | BFM11/3-200-1 |
Model and implication
Working Conditions
- Indoor use
- Altitude not more than 1000m
- Ambient temperature: -10~ 40
- Mounting sites shall have no bacterium, corrosive gas, explosive particles, conductive dusts, and no severe vibration
- Relative humidity: daily average: < 95%, month average: < 90%
- This device is only suitable for continuous working motor that it has no severe fluctuated loading, inverse rotation or inverse braking is forbidden, and it is not allowed to connect with speed adjustable motor.
- Rated voltage: 6-10KV
- Rated capacity as above sheet
- Rated current as above sheet.
- Wiring mode: Y (star) connected, neutral line earthed
Structure
The enclosure of the device can be made of panel material or steel bent formation, the panel upper part is meter door, downward part is steel door, inside door is provided with safe lock, rear panel is left ventilating door which it is locked by spiral lock, at normal working, this do or is not allowed to open except that the power is out of supply.
Selection
- Rated voltage of the device shall be equal the system voltage
- Rated voltage of the device shall be not bigger than motor no-loading current.
- Calculation of compensated capacity: as the methods of GGJ low voltage reactive auto compensation device.