Mineral Insulated Cable K/N/E/J/T/S/R/B Types 1-5m 200℃-1000℃

Price Negotiable
Price: negotiation
MOQ: 50M
Delivery Time: 2-7 working days
Brand: LEADKIN
Product Description
K/N/E/J/T/S/R/B Types Mineral Insulated Metal Sheathed Cable and Durable for Long-Term Performance
Product Specifications
Quick Details:
  • Type: K/N/E/J/T/S/R/B
  • Place of Origin: Zhejiang, China (Mainland)
  • Accuracy: I-0.4%t, II-0.75%t, III-1.5%t
  • Core number: 2,3,4,6
  • Inorganic mineral insulating lead material: Ni, Cu
  • Insulator: 99.6% high purity MgO
  • Certificate: ISO9001, IATF16949, CE
  • Application: connecting with thermocouple and instrument machine
  • Sheath material: 0Cr18Ni10Ti, SS304S, SS316L, SS316, Cu
  • Sheath Dia(mm): φ3.0, φ4.0, φ6.0, φ8.0
Sheath Wire Specifications
Type for Sheath Wire Type K:
Product Name Code Type Sheath Material Outside Dia. Temperature
NiCr-NiSi /NiCr-NiAl KK K SS304 SS316 0.5-1.0
1.5-3.2
4.0-8.0
400
600
800
SS310 Inconel600 0.5-1.0
1.5-3.2
4.0-6.4
8.0-12.7
500
800
900
1000
NiCrSi-NiSi NK N SS304 SS316 0.5-1.0
1.5-3.2
4.0-8.0
400
600
800
NiCr-Konstantan EK E SS304 SS316 0.5-1.0
1.5-3.2
4.0-8.0
400
600
800
Fe-Konstantan JK J SS304 SS316 0.5-1.0
1.5-3.2
4.0-8.0
400
600
800
Cu-Konstantan TK T SS304 SS316 0.5-1.0
1.5-3.2
4.0-8.0
400
600
800
RhPt10-Ph SK S Inconel600 6.0-12.7 1100

Note: Different temperature measuring media and service conditions have an impact on the service life and temperature range of armored thermocouples. The data in the table is only recommended data.

Accuracy for Sheath Wire Type K
Type Class I Class II
K ±1.5℃ (-40~375℃)
±0.4% (375℃-1000℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-1000℃)
N ±1.5℃ (-40~375℃)
±0.4% (375℃-1000℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-1000℃)
E ±1.5℃ (-40~375℃)
±0.4% (375℃-800℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-800℃)
J ±1.5℃ (-40~375℃)
±0.4% (375℃-800℃)
±2.5℃ (-40~375℃)
±0.75% (375℃-800℃)
T ±0.5℃ (-40~125℃)
±0.4% (125℃-350℃)
±1.0℃ (-40~125℃)
±0.75% (125℃-350℃)
S 0-1100℃ ±1.0℃ 0-1100℃ ±1.5℃
Product Applications

Thermocouple Connections: MI cables are commonly used to connect thermocouples to temperature measurement devices in applications such as furnaces, kilns, and chemical processing plants.

Instrumentation: Suitable for connecting various instruments in process control systems, including pressure, flow, and level sensors.

Oil and Gas Industry: Employed in drilling operations, pipelines, and refineries to monitor temperatures in extreme environments.

Power Generation: Used in turbines, boilers, and other critical components where precise temperature measurement is essential for safety and efficiency.

HVAC Systems: Applied in heating, ventilation, and air conditioning systems for accurate temperature monitoring and control.

Installation Considerations:
  • Bending Radius: MI cables have a specified minimum bending radius that should be adhered to during installation to avoid damaging the insulation.
  • Termination Techniques: Proper crimping or welding techniques should be used to ensure reliable electrical connections at the thermocouple junctions.
  • Environmental Factors: Consideration of factors such as temperature, pressure, and chemical exposure is critical during the selection and installation of MI cables.
Common Applications:
  • Solid waste incinerators
  • Sintering powdered metals
  • Firing ceramic materials
  • Gas or oil fired furnaces
  • Fuel fired heat exchangers
  • Box furnaces
  • Nuclear or hydrocarbon based energy plants
Product Images
Mineral Insulated Metal Sheathed Cable product photo
Company Information
Main Products
Leadkin main products Leadkin product line
Packaging

We add heat shrink tubing and plastic film to ensure high insulated resistance. Except marking notes, we also provide pass cards and test reports for every coil cable.

Leadkin cable packaging
MI Cable Production Line

We have high-quality professional products, as well as advanced product lines and equipment. All of our products comply with international quality standards and are greatly appreciated in various markets worldwide. We continuously update our products and improve our production systems to meet increasing market demands.

Order Process
  1. Accurate quotation
  2. Confirm price, trade terms, lead time, payment terms, etc.
  3. LEADKIN sales send Proforma Invoice with LEADKIN seal
  4. Customer arranges payment for deposit and sends bank slip
  5. Middle Production - photos showing production line with your products
  6. End Production - mass production product photos
  7. Client makes balance payment and LEADKIN ships goods
  8. Order completion when goods are received and customer is satisfied
  9. Feedback to LEADKIN about quality, service, and market suggestions
Frequently Asked Questions
What are the advantages of using thermocouples?
  • Wide temperature range
  • Fast response time
  • Simple and rugged design
  • Relatively inexpensive
  • Can be used in various environments, including extreme conditions
What are the disadvantages of thermocouples?
  • Non-linear output, requiring calibration
  • Accuracy may be lower than other temperature sensors (like RTDs)
  • Requires reference junction compensation for precise measurements
  • Susceptible to electromagnetic interference

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Ningbo Leadkin Instrument Complete Sets of Equipment Co., Ltd.
Location No.888 DONGMIN ROAD ZHUANGSHI STREET, ZHENHAI DISTRICT NINGBOCITY ZHEJIANG PROVINCE, CHINA
Contact Person Amy Jiang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.