Stainless Steel Globe Valve With Flange,API Standard, 150LB Pressure

 

 

Usage

 

This valve is mainly used to connect or cut off the medium in the pipeline. Generally, there is no need to adjust the flow.

 

Structure and action principle

 

1. This valve is flange connected, and the flange size shall comply with ANSI B 16.5 standard.

2. This valve is composed of valve body, bonnet, disc, stem, stem nut, handwheel and other parts. By rotating the handwheel, the stem rotates, and the stem drives the disc up or down to achieve the purpose of opening and closing.

 

Connection size

 

Type   DN L D D1 D2 b-f Z-Φd H1 H2 D0

 

 

 

J41W-150Lb

1 1/2 40 165 127 98.4 73 18-1.6 4-Ф16 236 260 160
2 51 203 152.4 120.7 92.1 19.5-1.6 4-Ф19 259 284 200
2 1/2 65 216 178 139.7 105 22.5-1.6 4-Ф19 312 348 240
3 80 241 190.5 152.4 127 24-1.6 4-Ф19 334 375 240
4 100 292 228.6 190.5 157 24-1.6 8-Ф19 389 441 280
5 125 356 254 215.9 186 24-1.6 8-Ф22 429 503 320
6 150 406 279.4 241.3 216 25.5-1.6 8-Ф22 476 554 400
8 200 495 343 298.5 270 29-1.6 8-Ф22 550 630 450

 

Material of main parts

 

Part Name  Material 
Body, Bonnet CF8
Disc CF8
Stem F304
Stem nut ZCuAI10Fe3

 

Possible faults and elimination methods

 

Possible failure Cause of failure Elimination method
Leakage of sealing surface

1. There are sundries and dirt between the sealing surfaces.

2. The sealing surface is damaged.

1 clean the dirt and sundries on the sealing surface.

2. Refinish the sealing surface.

Filler leakage

1. The packing gland is not tightened.

2. Insufficient filler.

3. Packing failure.

1. Evenly compress the packing.

2. Add filler.

3. Replace with new packing.

Leakage of flange connection sealing surface

1. The middle flange bolts are not tightened or the tightness is uneven.

2. The sealing surface of the connecting flange is damaged

1. Tighten the bolts evenly.

2. Refinish the flange sealing surface.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company China • Yuanda Valve Group Co., Ltd.
Location Jianshe South Street, Yuhua District, Shijiazhuang City, Hebei Province, China
Contact Person Ada Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.