1×N Optical Switch for Testing of Fiber, Optical Component, More Than 128 Channels.1x16 1x32 1x64 1x128
1xN High Reliability Optical Switches, 1x4 1x8 1x16 1x32 1x64 ,Ring Network ·Remote Monitoring in Optical Network
1×N Optical switch is a kind of functional component, with the ability of switching optical route. In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system.
Features
·More Than 128 Channels
·Low Loss and High Reliability
·Parallel Interface (TTL)
·Modularized Design
·Epoxy-free on Optical Path
Applications
·Ring Network
·Remote Monitoring in Optical Network
·Testing of Fiber, Optical Component
Specifications
| Parameters | Unit | GP-OSW1×N | |||
| Insertion Loss | dB | 1 < N ≤ 32 | 32 < N ≤ 64 | 64 < N ≤ 128 | |
| Type: 0.8 Max: 1.0 | Type: 0.8 Max: 1.2 | Type: 0.8 Max: 1.3 | |||
| Wavelength Range | nm | 850±40 / 1300±40,1550 MM | 1260 ~ 1650 SM | ||
| Test Wavelength | nm | 850 / 1300,1550 MM | 1310 / 1550 SM | ||
| Return Loss | dB | MM ≥ 30 SM ≥ 50 | |||
| Crosstalk | dB | ≥ 70 | |||
| PDL | dB | ≤ 0.05 | |||
| WDL | dB | ≤ 0.25 | |||
| TDL | dB | ≤ 0.25 | |||
| ER (PM swtich) | dB | ≥ 16 (PoIarization Maintaining switch) | |||
| Repeatability | dB | ≤ ±0.05 | |||
| Durability | Cycles | ≥ 10 Million | |||
| Switching Time | ms | ≤ 10(Sequence switch time of adjacent channel) | |||
| Optical Power | mW | ≤500 | |||
| Operating Temperature | ℃ | -5 ~ +70 | |||
| Storage Temperature | ℃ | -40 ~ +85 | |||
| Relative Humidity | % | 5 ~ 95 | |||
| Dimension | mm | 135×40×32 (N≤12) | 135×60×32(N≤18) | 135×60×38 (N≤32) | |
| 150×80×67 (N≤64) | 165×100×100 (N≤98) | 185×130×130 (N≤128) | |||
Pin Configurations
- DB-9 male connector (max.1×16)
| Pin No. | Signal Name | I / O | Description |
| 1 | D0 | Input | TTL, Channel selection bit 0 |
| 2 | D1 | Input | TTL, Channel selection bit 1 |
| 3 | D2 | Input | TTL, Channel selection bit 2 |
| 4 | D3 | Input | TTL, Channel selection bit 3 |
| 5 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
| 6 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
| 7 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
| 8 | GND | Input | Ground |
| 9 | +5VDC | Input | 5.0±5% VDC Power Supply (max 800mA) |
- DB-15 male connector (max.1×32)
| Pin No. | Signal Name | I / O | Description |
| 2 | D0 | Input | TTL, Channel selection bit 0 |
| 3 | D1 | Input | TTL, Channel selection bit 1 |
| 4 | D2 | Input | TTL, Channel selection bit 2 |
| 5 | D3 | Input | TTL, Channel selection bit 3 |
| 6 | D4 | Input | TTL, Channel selection bit 4 |
| 11 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
| 7 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
| 8 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
| 1, 9 | GND | Input | Ground |
| 15 | +5VDC | Input | 5.0±5% VDC Digital power supply (max 50mA) |
| 12 | VM | Input | 5.0±5% VDC or 12±5% VDC Drive power supply (max 800mA) |
| 14 | ISP | Input | TTL, For internal firmware upgrade of the module, in the normal mode, please suspended the pin; In the upgrade mode, please send the pin to ground. |
| 10, 13 | NA |
- DB-15 male connector (max.1×64)
| Pin No. | Signal Name | I / O | Description |
| 2 | D0 | Input | TTL, Channel selection bit 0 |
| 3 | D1 | Input | TTL, Channel selection bit 1 |
| 4 | D2 | Input | TTL, Channel selection bit 2 |
| 5 | D3 | Input | TTL, Channel selection bit 3 |
| 6 | D4 | Input | TTL, Channel selection bit 4 |
| 10 | D5 | Input | TTL, Channel selection bit 5 |
| 11 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
| 7 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
| 8 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
| 1, 9 | GND | Input | Ground |
| 15 | +5VDC | Input | 5.0±5% VDC Digital power supply (max 50mA) |
| 12 | VM | Input | 5.0±5% VDC or 12±5% VDC Drive power supply (max 800mA) |
| 14 | ISP | Input | TTL, For internal firmware upgrade of the module, in the normal mode, please suspended the pin; In the upgrade mode, please send the pin to ground. |
| 13 | NA |
- DB-15 male connector (max.1×128)
| Pin No. | Signal Name | I / O | Description |
| 2 | D0 | Input | TTL, Channel selection bit 0 |
| 3 | D1 | Input | TTL, Channel selection bit 1 |
| 4 | D2 | Input | TTL, Channel selection bit 2 |
| 5 | D3 | Input | TTL, Channel selection bit 3 |
| 6 | D4 | Input | TTL, Channel selection bit 4 |
| 10 | D5 | Input | TTL, Channel selection bit 5 |
| 13 | D6 | Input | TTL, Channel selection bit 6 |
| 11 | /RESET | Input | TTL, Low level reset to channel 0. High level means channel selection bits are effective. |
| 7 | /READY | Output | TTL, Ready (High=Not ready, Low=Ready) |
| 8 | ERROR | Output | TTL, Error (High=Error, Low=No error) |
| 1, 9 | GND | Input | Ground |
| 15 | +5VDC | Input | 5.0±5% VDC Digital power supply (max 50mA) |
| 12 | VM | Input | 5.0±5% VDC or 12±5% VDC Drive power supply (max 800mA) |
| 14 | ISP | Input | TTL, For internal firmware upgrade of the module, in the normal mode, please suspended the pin; In the upgrade mode, please send the pin to ground. |
Channel Selection Table
| Max Channel | Input | Active Channel | |||||||
| /RESET | D6 | D5 | D4 | D3 | D2 | D1 | D0 | ||
| N=16 | 0 | x | x | x | x | x | x | x | 0 reset |
| 1 | x | x | x | 0 | 0 | 0 | 0 | COM → 1 | |
| x | x | x | 0 | 0 | 0 | 1 | COM → 2 | ||
| x | x | x | 0 | 0 | 1 | 0 | COM → 3 | ||
| x | x | x | … | … | … | … | … | ||
| x | x | x | 1 | 1 | 1 | 1 | COM → 16 | ||
| N=128 | 0 | x | x | x | x | x | x | x | 0 reset |
| 1 | 0 | 0 | 0 | 0 | 0 | 0 | 0 | COM → 1 | |
| 0 | 0 | 0 | 0 | 0 | 0 | 1 | COM → 2 | ||
| 0 | 0 | 0 | 0 | 0 | 1 | 0 | COM → 3 | ||
| … | … | … | … | … | … | … | … | ||
| 1 | 1 | 1 | 1 | 1 | 1 | 1 | COM → 128 | ||
Optical Route
Timing Diagram
Dimension(DBx male head or female head is defined as the actual mark of the element)
- Ø 01: 135×40×32-DB9 (N≤12, DB-9 male)
- Ø 02: 135×60×32-DB9 (N≤16, DB-9 male)
- Ø 03: 135×60×32-DB15 (N≤18, DB-15 male)
- Ø 04: 135×60×38-DB15 (N≤32, DB-15 male)
- Ø 05: 150×80×67-DB15 (N≤64, DB-15 male)
- Ø 06: 185×130×130-DB15 (N≤128, DB-15 male)
Ordering Information:
General switch : GP-OSW1×N-AB-CD-EF
Polarization maintaining switch : GP-OSW1xN-PM-AB-CD-EF
| N | A | B | C | D | E | F |
| Channel | Fiber Type | Test Wavelength | Tube Type |
Fiber Length (Include connector) |
Connector | Dimension |
| 1 ~ 128 |
SM: SM, 9/125 M5: MM, 50/125 M6: MM, 62.5/125 X: Others |
85: 850nm 13: 1310nm 15: 1550nm 1315:1310/1550nm X:Others |
9: 900um 2: 2.0mm 3: 3.0mm X: Others |
05: 0.5m±5cm 10: 1.0m±5cm 15: 1.5m±5cm X: Others |
OO:None FP: FC/PC FA: FC/APC SP: SC/PC SA: SC/APC STP: ST/PC STA: ST/APC LP: LC/PC LA: LC/APC X: Others |
01: 135×40×32-DB9 02: 135×60×32-DB9 03: 135×60×32-DB15 04: 135×60×38-DB15 05: 150×80×67-DB15 06: 185×130×130-DB15 X: Others
|