Intelligent Fully Automatic Gas electric steam generator boiler 1.8KPA
WDL-MS The minimum gas pressure of 1.8KPA can be used with an intelligent fully automatic gas steam generator
Product Description:
1. Steam storage package for collection box
Ensure steam quality
Improve thermal efficiency
2. Nine speed linear transmission experience
Steam volume 1:9, ultra long adjustment ratio
Minimum steam flow rate as low as 150kg/h
Stable steam pressure, energy-saving
3. Efficient 316L condensing heat exchanger configuration
High temperature energy-saving device
Low temperature condenser
Smoke exhaust temperature as low as 55 ℃
Thermal efficiency reaches 100.1%
4. Low NOx emission technology
Advanced combustion process control
NOX emissions as low as 10mg/m3
5. No usage certificate, no operation certificate, and no annual inspection required
The water volume of the main body is less than 30L
Pressure range 1.0/1.3/1.6 MPa
6.360 ° Uniform Radiation Water Pipe Heat Transfer Technology
Each water pipe balances heat exchange
Avoid local overheating and prevent scaling and pipe bursting
Extend the service life of equipment
7. Low gas pressure combustion technology
Minimum 1.8kpa gas pressure
Micro positive pressure combustion, stable operation
Faced with pressure fluctuations in the pipeline network
8. Intelligent IoT remote control system
Boiler fully automatic operation
Inch color touch screen
Multiple regulation and protection functions
Group control function and remote monitoring
Main specification:
| Series product model | unit |
MS1000-1.0
|
MS1350-0.8
|
MS2000-0.8
|
MS3000-0.8
|
|
| Main product model |
/
|
LSS0.5-1.0-Q
|
LSS1-0.8-Q
|
LSS1-0.8-Q
|
LSS1-0.8-Q | |
| rated evaporation |
kg/h
|
1000
|
1350
|
2000
|
3000
|
|
| Evaporation regulation ratio |
1:6
|
1:6
|
1:6
|
1:9
|
||
|
water capacity
|
L
|
<30
|
<50
|
<50
|
<50
|
|
| Rated steam pressure |
Mpa
|
1.0
|
0.8
|
0.8
|
0.8
|
|
| Saturated steam temperature |
℃
|
184
|
175
|
175
|
175
|
|
|
nox emission |
mg/m³
|
<30
|
<30
|
<30
|
<30
|
|
|
Gas pressure requirements
|
Kpa
|
1.8-6
|
1.8-6
|
1.8-6
|
1.8-6
|
|
|
Power supply requirements
|
power supply |
V/Hz
|
380/50
|
380/50
|
380/50
|
380/50
|
| Distribution power |
KW
|
5 | 6 | 7.2 | 10.8 | |
| 20 ℃ water supply condition | Design thermal efficiency |
%
|
101
|
101
|
101
|
101
|
| Design exhaust temperature | ℃ |
58
|
58
|
58
|
58
|
|
| Gas consumption design |
m³
|
74.6
|
100.7
|
149.2
|
223.8
|
|
| External dimensions | long |
mm
|
2300
|
2300
|
2300
|
2300
|
| wide |
mm
|
2300
|
2300
|
2300
|
2300
|
|
| high |
mm
|
2460
|
2460
|
2460
|
2460
|
|
|
interface size
|
Inlet diameter |
mm
|
DN40
|
DN40
|
DN40
|
DN40
|
| Steam caliber |
mm
|
DN50
|
DN65
|
DN80
|
DN100 | |
| Discharge caliber |
mm
|
DN40
|
DN40
|
DN40
|
DN40
|
|
| Gas caliber |
mm
|
DN50
|
DN65
|
DN65
|
DN65
|
|
| Chimney diameter |
mm
|
2xφ219
|
2xφ219
|
2xφ219
|
3xφ219
|
|
Note: The enthalpy value of steam is calculated based on a gauge pressure of 0.8 MPa and a feed water temperature of 20 ℃ at 2772.1 kj/kg. The calorific value of natural gas is calculated based on a lower heating value of 8500 kcal/m ³;
The parameter configuration has changed due to the continuous improvement of the product, and the specific parameters are subject to the product leaving the factory.
Get in Touch