2mm Ultra-thin PD External Optical Power Probe +10 To -45dBm

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: 21 work days
Brand: YOUCii
Product Description

2mm Ultra-thin PD External Optical Power Probe +10 To -45dBm 


Ultra-thin design
The typical probe thickness is only 2.0-4.5 mm (the front-end dimensions of the U82024 model are 5.0mm W×2.5mm H×20.0mm D, but the detection surface thickness is extremely thin), which can be easily integrated into compact optical systems or narrow Spaces.


High-precision detection
The InGaAs detector is adopted, with a wavelength range covering 900-1700nm, meeting the requirements of the communication band (1310/1550nm) and extended bands.
The absolute accuracy reaches ±4% (1200-1650nm), the relative accuracy is less than 0.02dB, and the power linearity is ≤±0.06dB, ensuring precise measurement of both weak and strong light signals.



Model #

U82024

Sensor Element

InGaAs

PD Size

φ2 mm

Wavelength Range

900 ~ 1700 nm

Calibration wavelength

1310 / 1550 / 1650nm Segmented calibration

Power Range

+10 ~ - 45 dBm

Power sampling period(rate)

1 ms(1KHz)

Application Fiber Type  


Standard SM and MM up to 62.5 um core size

 Absolute

Uncertainty (accuracy) at reference condition

± 4% (1200 nm ~ 1650 nm)

Relative

Uncertainty (accuracy) at reference condition  

 0.02 dB Typical

Linearity (power)

 ± 0.06 dB (1200 nm ~ 1650 nm, 0 ~ -40dBm)

Return Loss

 40 dB

Optical Input Interface

Bare fiber input

Probe front dimension

5.0 mm W x 2.5 mm H x 20.0 mm D

Communication Interface

RS232 / USB

Operation Temperature

0  +40

Storage Temperature

-30  +80

Recalibration Period

2 Year

Dimensions

5 mm W, 2.5 mm H, 20 mm D

Weight

0.5 kg


Flexible interfaces and durability
It provides RS232/USB communication interfaces, facilitating data transmission and system integration.
The operating temperature range is 0-40℃, and the storage temperature range is -30-80℃. It is suitable for harsh environments.
The calibration cycle is 2 years, reducing long-term maintenance costs.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangzhou UC Instruments., Co. Ltd.
Location R102, #24 Huangcun East Road,Tianhe District, Guangzhou 510660
Contact Person Jack Zhou

Request A Quote

Please check your email address.
Your message must be at least 20 characters.