ADIS16488 10-Axis Inertial Measurement Unit with 0.8°/hr Bias Stability for Unmanned Vehicles
Price:
600$
MOQ:
1
Delivery Time:
1 week
Brand:
FIREPOWER
Product Description
Product Overview
Engineered with advanced MEMS technology, the 16488HB IMU delivers accurate 3-axis angular velocity and 3-axis acceleration data for industrial and commercial applications. Equipped with a triaxial magnetometer (2.5gauss) and digital barometer (300-1100mbar), it supports high-precision positioning and motion tracking. Designed to withstand 1000G impact and 6.06G vibration, it excels in unmanned motion carriers, communication in motion, and mapping projects.
Product Features
-
Three-axis digital gyroscope:
- ± 2000º/s dynamic measurement range;
- Zero bias stability: 3 °/H (GJB, 10S, Z-axis), 0.8 °/H (ALLAN, Z-axis);
-
Triaxial digital accelerometer:
- ± 200g dynamic measurement range;
- Zero bias stability: 0.4mg (GJB, 10S), 0.06mg (ALLAN);
-
Triaxial digital magnetometer: 2.5g auss
-
Digital barometer: 300mbar ~ 1100mbar
-
High reliability: MTBF 20000h;
-
Guaranteed accuracy within the full temperature range (-40 ℃ ~ + 80 ℃):
built-in high-performance temperature calibration and compensation algorithm;
-
Suitable for operation under strong vibration (6.06 G, 20 ~ 2000 Hz);
-
Suitable for working under large impact conditions (1000 G, 0.5ms);
Field of Application
- Unmanned motion carrier
- Communication in motion
- Surveying and mapping
- Stabilizing platform
Product Indicators
16488HB Product Index
| Parameter | Test conditions | Minimum value | Typical value | Maximum value | Unit | |
|---|---|---|---|---|---|---|
| Gyroscope | Dynamic measuring range | 500 | 2000 | °/s | ||
| Zero bias stability | Allan variance, Z-axis | 0.8 | °/h | |||
| Allan variance, X and Y axis | 1.6 | °/h | ||||
| 10 s average (-40 ℃ ~ + 70 ℃, constant temperature), Z-axis |
3 | °/h | ||||
| 10 s average (-40 ℃ ~ + 70 ℃, constant temperature), X-axis and Y-axis |
6 | °/h | ||||
| Zero bias | Zero-bias range, Z-axis | ±0.07 | °/s | |||
| Zero-bias range, X-axis and Y-axis | ±0.2 | °/s | ||||
| Zero-bias change in full temperature range, Z-axis ① | ±0.02 | °/s | ||||
| Zero Bias Change Over Temperature, X and Y Axis ① |
±0.06 | °/s | ||||
| Successive Start Repeatability, Z-axis | 0.002 | |||||
| Successive Start Repeatability, X-Axis and Y-Axis | 0.006 | |||||
| Day-by-day start repeatability, Z-axis | 0.003 | /s | ||||
| Start repetition day by day, X axis and Y axis | 0.009 | °/s | ||||
| Ffect of linear acceleration on bias | 0.002 | °/s/g | ||||
| Influence of vibration on zero bias, change before and after vibration ② | 0.002 | °/s/g | ||||
| Influence of vibration on zero bias, change before and during vibration ② | 0.002 | °/s/g | ||||
| Scale factor | Scale factor accuracy, Z-axis | 0.3 | % | |||
| Scale Factor Accuracy, X and Y Axis | 0.6 | % | ||||
| Scale factor nonlinearity, Z-axis | 0.01 | %FS | ||||
| Scale Factor Nonlinearity, X and Y Axis | 0.02 | %FS | ||||
| Angular random walk | 0.15 | °/ √hr | ||||
| Noise density | 0.001 | °/s/ √Hz | ||||
| Resolution | 3.052*10-7 | /s/LSB | ||||
| Bandwidth | 200 | Hz | ||||
| Parameter | Test conditions | Minimum value | Typical value | Maximum value | Unit | |
|---|---|---|---|---|---|---|
| Accelerometer | Dynamic measuring range | 16 | 200 | g | ||
| Zero bias stability | Allan variance | 0.06 | mg | |||
| 10 s average (-40 ℃ ~ + 70 ℃, constant temperature) | 0.4 | mg | ||||
| Zero bias | Zero bias range | 2 | mg | |||
| Change of zero bias within the whole temperature range, peak-to-peak value ① | 4 | mg | ||||
| Repeatability of successive starts | 0.5 | mg | ||||
| Repeatability is initiated on a daily basis | 0.8 | mg | ||||
| Zero-bias temperature coefficient | 0.05 | 0.1 | mg/℃ | |||
| Magnetometer | Magnetic field range | Brg,xy | ±13 | gauss | ||
| Brg,z | ±25 | gauss | ||||
| Resolution | 0.3 | μT | ||||
| Heading accuracy | 30 μT horizontal geomagnetic component, 25 ℃ | ±2.5 | deg | |||
| Dynamic measuring range | 2.5 | gauss | ||||
| Zero bias | Non-magnetic environment | 15 | mgausS | |||
| Barometer | Dynamic measuring range | 300 | 1100 | mbar | ||
| Zero bias | 4.5 | mbar | ||||
| Communication interface | 1-way SPI | Baud rate | 15 | MHz | ||
| Sampling frequency | SPI | 2460 | 2460 | Hz | ||
| 1-Way C A N | Baud rate | 1 | MHz | |||
| CAN | 200 | |||||
| Electrical characteristics | Voltage | 3.0 | 3.3 | 3.6 | V | |
| Power consumption | 1.5 | W | ||||
| Ripple | P-P | 100 | mV | |||
| Settling time | From 0 V to 3. 3V | 80 | ms | |||
| Structural characteristics | Size | 47*44*14 | mm | |||
| Weight | 50 | g | ||||
| Use environment | Operating temperature | -40 | 70 | ℃ | ||
| Storage temperature | -45 | 75 | ℃ | |||
| Vibration | 20~2000Hz, 6.06g |
|||||
| Impact | 1000g,0.5ms | |||||
| Reliability | MTBF | 20000 | h | |||
| Continuous working time | 120 | h | ||||
| ①: Calculate the zero deviation of the whole temperature change process, the temperature change rate is ≤ 1 ℃/min, and the temperature range is -40 ℃ ~ + 70 ℃ ②: Vibration condition is 6.06 G, 20Hz ~ 2000Hz |
||||||
Outline Drawing
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Fire Power Control Technology Co., LTD
Location
429, Building A10, Fuhai Information Port, Xinhe Community, Fuhai Street, Shenzhen, Guangdong, China
Contact Person
Caine