Use this procedure in order to troubleshoot a high turbocharger turbine inlet temperature. Also, use this procedure if one of the following diagnostic codes is active or easily repeated.
Table 1
Diagnostic Codes Table
J1939 Code and Description Conditions which Generate this Code System Response
1180-15
Turbocharger #1 Turbine Inlet Temperature : High - least severe (1) The exhaust temperature is above the trip point temperature. The code is logged.
1180-16
Turbocharger #1 Turbine Inlet Temperature : High - moderate severity (2) The exhaust temperature is above the trip point temperature. The code is logged.
The engine is derated.
1180-0
Turbocharger #1 Turbine Inlet Temperature : High - most severe (3) The exhaust temperature is above the trip point temperature. The code is logged.
The engine is shut down.
1181-15
Turbocharger #2 Turbine Inlet Temperature : High - least severe (1) The exhaust temperature is above the trip point temperature. The code is logged.
1181-16