1x1 Cut On Off Mechanical Optical Switch Configurable Optical Add Drop
1x1 Cut On/Off Optical Switches
The 1x1 Mechanical optical switch is connected to the optical path by connecting or blocking the optical signal, the product is controlling by electrical signal to switch the optical path.
Corephy 1x1 Fiber Optical Switches is designed for use in optical fiber communication networks and measurement instruments. The 1x1 On/off Fiber Optical switches consists of two ports that selectively transmits, redirects, or blocks optical power in a fiber optic transmission line.
The 1x1 Cut On/Off opto-mechanical Fiberoptic switches must be actuated to select or change between two states. As a result, it consumes low electric energy to operate the optical switch.
|
Application Optical Signal Routing Optical Netrwork Protection/Restoration Configurable Optical Add/Drop |
Compliance |
Technical index
| Parameters | CP-FSW-1x1 | ||
| Wavelength Range | nm | 850±40/1300±40 | 1260~1650 |
| Operating avelength | nm | 850/1300 | 1310/1490/1550/1625/1650 |
| Insertion Loss | dB | Typ:0.5 Max:0.8 | Typ:0.5 Max:0.8 |
| Return Loss | dB | MM≥30 SM≥50 | |
| Crosstalk | dB | MM≥35 SM≥55 | |
| PDL | dB | ≤0.05 | |
| WDL | dB | ≤0.25 | |
| TDL | dB | ≤0.25 | |
| Repeatability | dB | ≤±0.02 | |
| Power Supply | v | 3.0 or 5.0 | |
| Lifetime | times | ≥107 | |
| Switch Time | ms | ≤8 | |
| Transmission Power | mW | ≤500 | |
| Operating Temperature | ℃ | -20~+70 or -45~+85 | |
| Storage Temperature | ℃ | -40~+85 | |
| Weight | g | 16 | |
| Dimension | mm | (L)27.0×(W)12.0×(H)8.2 | |
Pins
| Parameters | Pins | Electric Drive | Status Sensor | ||||||
| 1x1 | Optical Path | 1 | 5 | 6 | 10 | 2-3 | 3-4 | 7-8 | 8-9 |
| Non-latching | light close | -- | -- | -- | -- | Close | Open | Open | Close |
| P1-P2 | V+ | -- | -- | GND | Open | Close | Close | Open | |
| latching | light close | -- | -- | GND | V+ | Close | Open | Open | Close |
| P1-P2 | V+ | GND | -- | -- | Open | Close | Close | Open | |
Route States
| Status One | Status Two |
|
|
![]() |
Ordering Information
| Type | Wavelength | Voltage Type | Control Model | Fiber Type | Fiber Diameter | Fiber Length | Connector |
| 1x1 |
85=850nm 13=1310nm 15=1550nm 13/15=1310/1550nm X=Others |
3=3V 5=5V |
L=Latching N=Non- Latching |
5=50/125 6=62.5/125 9=9/125 X=Others |
25=250um 90=900um 20=2.0mm 30=3.0mm X=Others |
1=1m 2=1.5m X=Others |
00=none |
Applications:
R&D in Laboratory
System Monitoring
OADM
MAN (Metropolitan Area Network)
Specifications:
|
Parameters |
Unit |
HT-OSW-1×2 |
|
|
Operating Wavelength |
nm |
SM:1260~1620 |
MM:850±40 |
|
Test Wavelength |
nm |
1310 / 1550 |
850 |
|
Insertion Loss |
dB |
≤0.7(typical:0.5) |
|
|
Wavelength Dependent Loss |
dB |
≤0.25 |
|
|
Temperature Dependent Loss |
dB |
≤0.2 |
|
|
Polarization Dependent Loss |
dB |
≤0.05 |
|
|
Return Loss |
dB |
SM≥50,MM≥30 |
|
|
Crosstalk |
dB |
SM≥55,MM≥35 |
|
|
Repeatability |
dB |
≤±0.02 |
|
|
Swtich Time |
ms |
≤8 |
|
|
Durability |
times |
≥10 million |
|
|
Operating Voltage |
V |
3.0 or 5.0 |
|
|
Optical Power |
mw |
≤500 |
|
|
Operating Temperature |
℃ |
-5~+70 |
|
|
Storage Temperature |
℃ |
-40~+85 |
|
|
Operating Humidity |
℃ |
5~95 |
|
|
Dimension |
mm |
L27xW12xH8.2 |
|
|
Note:1.Within operating temperature and all SOP. |
|||
|
2.Excluding connector, and add 0.2dB IL for each connector. |
|||
Optical Route
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.