Programmable Controller Xenon Lamp Weather Resistance Test Chamber OEM
Programmable Controller Xenon Lamp Weather Resistance Test Chamber OEM
Function:
2. To get the results of damage after several days or weeks which is equal to expose to outside for a few months. The damages include fading, discoloration, brightness down, powder, crack, blur, brittle, strength decreases and oxidation.
3. Provide reference with testing data for improvement of existing materials, or to assess the impact of changes in product durability and other aspects.
Feature :
Our UV aging test chamber series includes 4 different types of UV aging test boxes, QUV/se, QUV/basci, QUV/spray and QUV/cw. It can meet the testing standards of coatings, ink, adhesives, plastic products and other industries.
1. Different test methods and procedures: Automatic control, real-time monitoring and display.
2. The sample frame temperature: Sample temperature BPT directly display and automatic control.
3. Condensation control: Condensation directly display and automatic control.
4. Circular manner: Light, condensation and spray directly display and automatic control.
5. Light irradiance: Testing process can be set light irradiance energy and time and monitoring.
6. Spray water: Adjustable and display, automatic control, test process can be set spraying time
.
7. The calibration function: Automatic temperature calibration, convenient, fast.
8. Alarm function: Automatic alarm .
9. Water supply way: Automatic feed water.
10. PC connection method : RS232
|
Item
|
Specification
|
|
Chamber dimension (W*D*H)
|
1300*500*1460mm
|
|
Chamber material
|
SUS#304 stainless steel
|
|
Temperature range
|
RT to 70℃
|
|
Temperature fluctuation
|
≤±1.0℃
|
|
Temperature uniformity
|
3℃
|
|
Humidity range:
|
≥75%RH
|
|
Controller
|
Programmable controller, LCD touch screen
|
|
Control mode
|
Balance temperature humidity control (BTHC)
|
|
Test cycle setting
|
Exposure, condensation and water spray test cycle is programmable
|
|
Water spray cycle
|
Spray 18mins in every 120mins / spray 12mins in every 60mins
|
|
Water usage
|
8L/day
|
|
Distance from sample to lamp
|
55±2mm
|
|
Centre distance between lamps
|
65~70mm
|
|
Irradiance range
|
0.45~0.90W/m2
|
|
UV lamps
|
Imported Atlas UV-A: 315-400nm (8pcs, 1600h lifetime)
|
|
Lamp power
|
40W/Piece
|
|
Specimen Size
|
75×290mm (24pcs) / 75x150mm (48pcs), maximum thickness 5mm
|
|
Testing time
|
0~999H, adjustable
|
|
Protection system
|
Overload short circuit protection
Over temperature protection Water lacking protection Earth leakage protection Auto shut off protection |
|
Observation window
|
Tempered glass
|
|
Testing hole
|
Diameter 50mm, for cable routing
|
|
Sample tray
|
SUS#304 stainless steel, 2pcs
|
|
Safety protection device
|
Protection for leakage
Over-temperature Compressor overvoltage and overload Heater short circuit Water shortage |