HFNC oxygen therapy was introduced, accompanied by heated humidification systems to prevent the associated drying or upper airway mucosa and to increase patient comfort.
High quality Lifotronic oxygen High flow nasal cannula HFNC respiratory humidifier
Price:
$2,355.60/Sets 1-4 Sets
MOQ:
1pc
Delivery Time:
about 5 days
Brand:
Lifotronic
Product Description
Product Description

What is high flow nasal cannula(HFNC)?
HFNC was first introduced into clinical practice in the early 2000s as a noninvasive system to manage apnoea in premature neonates and since then its use in paediatrics, particularly in respiratory failure caused by bronchiolitis, is well established.
Successively, HFNC has been investigated in adults with acute respiratory failure, gaining increasing popularity among intensivists. More recently, the use of this new device has spread out of intensive care units (ICUs), particularly the respiratory units where it is widely and increasingly used, often replacing NIV in the management of respiratory failure from a variety of aetiologies.

Decrease Breathing Workload
The high-flow can reach or exceed the maximum inspiratory flow rate of the patient's active inhalation, reducing inhalation resistance and breathing work, and reducing oxygen consumption; The inhaled gas of HFNC is the ideal inhaled gas, which replaces the humidification function of the patient’s upper airway and reduces the metabolic work of the respiratory tract.

Dead space washout
Recent studies show that nasal high flow (NHF) therapy can support ventilation in patients with acute or chronic respiratory disorders. Clearance of dead space has been suggested as being the key mechanism of respiratory support with NHF therapy.

HFNC VS NIV
Due to poor mask tolerance,NIV is inapplicable to some patients
The major difference between NIV and HFNC is the interface Whereas NIV interfaces increase anatomical dead space,HFNC decreases dead space HFNC is the only noninvasive respiratory support that does not increase dead space. The simplicity and excellent tolerance of the system is attractive.


Functional residual capacity enhancement 25% with HFNC
FRC:Functional residual capacity
Why Choose Us
✔ Optimal heat
Multiple temperature settings (31-37℃, increment 1℃)
✔ Optimal humidity
Active humidity humidified at 44 mg H2O/L
✔ No mouth or nasal drying
✔ No mask removal
✔ Better communication
✔ Different Size Nasal Cannula Choosable

No disinfection necessary. the patient circuit is
disposable and detachable.
One way valve design to avoid gas back to the unit.
Carry out disinfection cycle with disinfection tube.

Dual spiral heater wires (reduces heat loss and reduces condensation) Unique integrated temperature sensor Lightweight, flexible delivery tubing

Soft and flexible nasal prongs Wide-bore design reduces gas jetting Prongs contoured to the patient’s nose Adjustable head strap (Easier readjustment) Improves prong stability in the nostrils

Specification
|
Model
|
Hi-800
|
|
Device Classification
|
Class II
|
|
Purposes
|
Warmed and humidified respiratory gases
|
|
Flow rate range
|
2-80L/min
|
|
Oxygen percentage range
|
21%-100%
|
|
Adjustment method of oxygen concentration
|
Built-in electronic flow meter and controllers
|
|
Temperature range
|
31℃-37℃,increment 1℃
|
|
Interface
|
5-inch color LCD touch screen
|
|
Humidity
|
≥33mg/L at 37℃ target
|
|
Water chamber
|
Volume: ≥90mL
|
|
|
Automaticly fill liquid to the required level and retain the level
|
|
Session time
|
0-24h
|
|
Disinfection tube
|
Yes
|
|
Length of heating tube
|
1.9m
|
|
Alarms
|
12 types of alarms
|
|
Accessories(Sold Separately)
|
Water chamber, heating breathing tube, nasal cannula(adult, infant),tracheostomy interface
|
|
Lifetime of the unit
|
10 years
|
|
Power Cord
|
Hospital Grade Plug
|
|
Controller Dimensions
|
Height: 28.4cm
Width: 39.4cm Depth: 21.2cm |
|
Controller Weight
|
3.75kg
|
|
Power Supply
|
100-240 VAC, 550VA, 50/60 Hz
|
|
Shipping Case Dimensions
|
Height: 43.5cm
Width: 45.5cm Depth: 30.0cm |
|
Shipping Case Weight
|
6.0kg
|
|
Noise Max.
|
50dB
|
|
Operating Conditions
|
Temperature: 18°C to 28°C
Relative Humidity: 80% Maximum, non-condensing Atmospheric Pressure: 750 mbar to 1060 mbar |
|
Transport & Storage Conditions
|
-20°C (-4°F) to 55° C (131°F)
If the user suspects that the environment conditions for transport and storage have been exceeded, return the unit for service. |
Certificates


Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
SUCE (HONG KONG) IMPORT AND EXPORT LIMITED
Location
ROOM 702,7/F, SPA CENTRE,NO. 53-55 LOCKHART ROAD,WAN CHAI, HONG KONG
Contact Person
JUCCY