| Parameter | Specification |
|---|---|
| Nominal Voltage | 80V |
| Nominal Capacity | 870Ah |
| Energy Capacity | 69.6 kWh |
| Battery Chemistry | LiFePO4 (LFP) |
| Cycle Life (@80% DOD) | ≥4,000 cycles |
| Standard Charging Current | 174A (0.2C) |
| Fast Charging Current | 435A (0.5C) |
| Charging Time (Standard) | 5.0 hours |
| Charging Time (Fast) | 2.0 hours |
| Continuous Discharge Current | 870A (1.0C) |
| Peak Discharge Current (60s) | 1,305A (1.5C) |
| Operating Temperature (Charge) | 0°C to +55°C |
| Operating Temperature (Discharge) | -20°C to +60°C |
| IP Rating | IP67 |
| Communication Protocol | CAN Bus 2.0B, RS485, Modbus TCP (optional) |
| Weight | Approx. 820 kg |
| Dimensions (L*W*H) | 1,250*850*780 mm (Customizable) |
| Installation Type | Side-extraction / Roll-out compatible |
| Warranty | 5 years / 4,000 cycles |
| Certifications | UL 1973, CE, UN38.3, IEC 62133, IEC 62619 |
With 69.6 kWh of stored energy, this battery eliminates the need for battery swapping in most three-shift operations. When paired with opportunity charging stations at staging areas, the system can operate continuously across multiple shifts without dedicated battery change-out personnel or spare battery inventory. This configuration reduces capital expenditure on backup battery assets and associated charging infrastructure.
-
Dual-module architecture: Independent BMS control for each half-pack ensures redundancy and fault isolation
-
Liquid cooling readiness: Optional thermal management channels for high-duty-cycle tropical operations
-
Reinforced steel enclosure: Impact-resistant housing rated for industrial material handling environments
-
Advanced BMS with data logging: 180-day operational history storage for fleet analytics and predictive maintenance
-
High-current busbar design: Low-resistance copper terminals rated for sustained 870A discharge
| Category | Parameter | Value |
|---|---|---|
| Electrical | Nominal Voltage | 80V |
| Electrical | Nominal Capacity | 870Ah |
| Electrical | Energy | 69.6 kWh |
| Electrical | Cell Type | Prismatic LiFePO4 |
| Electrical | Configuration | 25S8P (Dual 25S4P modules) |
| Electrical | Internal Resistance | ≤8 mΩ |
| Electrical | Self-Discharge Rate | <2% per month |
| Charging | Standard Charge Voltage | 87.5V |
| Charging | Max Charge Voltage | 91.25V |
| Charging | Standard Charge Current | 174A (0.2C) |
| Charging | Max Charge Current | 435A (0.5C) |
| Charging | Charge Temperature Range | 0°C to +55°C |
| Discharging | Cut-off Voltage | 62.5V |
| Discharging | Continuous Current | 870A (1.0C) |
| Discharging | Peak Current (60 sec) | 1,305A (1.5C) |
| Discharging | Discharge Temperature | -20°C to +60°C |
| BMS | Protection Features | Overcharge, over-discharge, over-current, short circuit, temperature, insulation fault protection |
| BMS | Balancing Method | Active balancing with cell-level monitoring |
| BMS | Communication | CAN Bus 2.0B, RS485, Modbus TCP (optional) |
| BMS | Data Logging | 180-day operational data storage |
| Mechanical | Enclosure Material | Heavy-gauge powder-coated steel |
| Mechanical | Dimensions (L*W*H) | 1,250*850*780 mm |
| Mechanical | Weight | ~820 kg |
| Mechanical | IP Rating | IP67 |
| Mechanical | Terminal Type | Copper busbar M12 |
| Environmental | Operating Humidity | ≤95% RH (non-condensing) |
| Environmental | Altitude | ≤3,000 m |
| Environmental | Cooling | Natural convection / Optional liquid cooling |
| Compliance | Certifications | UL 1973, CE, UN38.3, IEC 62133, IEC 62619, ISO 9001 |
| Compliance | Warranty | 5 years or 4,000 cycles (whichever comes first) |
-
Toyota: 8FBN15-30, 8FBE20U series
-
Hyster: J3.0-5.5XN, E4.0-5.5XN series
-
Yale: GDP/GLP 30-55VX series (electric variants)
-
Linde: E25-E50 series
-
KION: Baoli KBE series (80V heavy-duty)
-
Doosan: B25X-7, B30X-7 series
| Certification | Scope | Significance |
|---|---|---|
| UL 1973 | North American motive power safety | Required for industrial vehicle deployment in US/Canada |
| CE | European conformity | Mandatory for EU and EEA market access |
| UN38.3 | UN transport testing | Certifies safe transport by air, sea, and land |
| IEC 62133 | Secondary cell safety | International baseline for lithium battery safety |
| IEC 62619 | Industrial secondary lithium batteries | Specific to high-capacity industrial applications |
| ISO 9001 | Quality management | Consistent design and manufacturing quality |
— Sarah L., VP of Operations, Coastal Logistics Group
The CAN Bus 2.0B interface broadcasts real-time data including: state of charge (SOC), state of health (SOH), individual cell voltages, pack temperature, charge/discharge current, cycle count, and fault codes. This data integrates with most fleet telematics platforms and forklift OEM display systems.
Get in Touch