OVF30 inverter fault code description
1. Base (GATE SUPPLY) fault
The hardware has detected insufficient voltage in the IGBT gate drive circuit.
(1)check whether the grounding of the inverter is good; 

(2)replace the XU2 board and UD3 board;

(3)replace the inverter
2. Inverter OCT inverter output overcurrent
(1)check the parameters INVTR OCT, DRIVE RTD I RMS, INV IFSCALE;

(2)check whether there is a short circuit or insulation problem on the motor side;

(3)check whether the brake is fully opened;

(4)check the PVT and wiring; (5), replace the inverter
3. IGBT Desatuation/
Problems with IGBT devices and related circuits such as gate drive circuits
(1)replace the base and UD3 board;

(2)replace the inverter

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Xian Sulab Machinery Co., Ltd.
Location Wanda Square Plaza, Weiyang district, Xi'an City, Shaanxi China
Contact Person Eric Cheng

Request A Quote

Please check your email address.
Your message must be at least 20 characters.