Quatanary Pump HPLC High Performance Liquid Chromatography Instrument for Pharmaceutical Analysis
Description of Liquid Chromatography Instrument

The high performance liquid chromatography instrument is used to analyze less-volatile and thermal-unstable organic compounds with high boiling point and large molecular weight. It consists of reservoir, pump, sample injector, chromatographic column, detector and recorder.

Parameters of Liquid Chromatography Instrument

Binary Pump HPLC High Performance Liquid Chromatography With UV ELSD DAD Detetcor

Pump

 
Gradient  Quaternary low pressure
Flow Rate Range 0-10.0000mL/min
Flow Rate Setpoint Error ±0.2%
Flow Rate Repeatability ≤ 0.08% RSD
Gradient Stability < 0.5% RSD
Maximum Working Pressure 45MPa
In-line Degassing 5
Column Oven  
Temperature Setting Range 4 ℃ ~ 85 ℃
Temperature Stability ≤±0.02 ℃
Autosampler  
Injection Volume 0.1-20.0μL
Sample Capacity 120 Vials
Injection Linearity r > 0.9999
Inlet Cross-contamination < 0.002%
Accuracy Error of Injection Volume ±0.2μL
Injection Volume Repeatability < 0.3% RSD
Injection Speed 15 s
UV Detector  
Wavelength Range 188 - 900 nm (optional tungsten lamp)
Wavelength Error ≤ ±0.5 nm
Wavelength Repeatability ≤ ±0.1 nm
Baseline Noise 0.8 × 10-5 AU
Baseline Drift 1.0 × 10-4 AU/h
Linear Range 2.5AU
DAD Detector  
Wavelength Range 190 - 800 nm
Wavelength Error ≤ ±1.0 nm
Wavelength Repeatability ≤ ±0.1 nm
Baseline Noise 6× 10-5 AU
Baseline Drift 1 × 10-3 AU/h
Linear Range 2.0 AU
Workstation SmartLab( Self-development)

Characteristics of Liquid Chromatography Instrument 
1. Mainstream split design, complete system testing function, to meet most testing needs

2. The new cam curve design adopts electronic pulsation suppression technology and solvent

3. Compression compensation to further reduce pressure fluctuations and ensure higher repeatability of test results.

4. Optional UV, ELSD, FLD,DAD and RID detectors.
 

 


 

 

 
 
 
 
 
 
 
 
 
 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Anhui Wanyi Science and Technology Co., Ltd.
Location No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Contact Person Annie

Request A Quote

Please check your email address.
Your message must be at least 20 characters.