FLD Detector HPLC Chromatography Machine In Pesticide Residue Analysis

Price Negotiable
Price: Negotiation
MOQ: 1
Delivery Time: 30 days
Brand: Wayeal
Product Description

FLD Detector High Pressure Liquid Chromatography Machine in Pesticide Residue Analysis
 Description of Liquid Chromatography Instrument

High-performance liquid chromatography or high-pressure liquid chromatography (HPLC) is a chromatographic method that is used to separate a mixture of compounds in analytical chemistry and biochemistry so as to identify, quantify or purify the individual components of the mixture. In very small amounts, the sample mixture to be separated and tested is sent into a stream of mobile phase percolating via a column. The mixture moves through the column at varying velocities and interacts with the sorbent, also known as the stationary phase. 

Parameters of Liquid Chromatography Instrument

FLD Detector High Pressure Liquid Chromatography Machine in Pesticide Residue Analysis
Physical Specification  
Power Requirements 220V,50HZ
Ambient Temperature 4-40℃
Ambient Humidity 20-85% relative humidity(non-condensing)
System  
Qualitative repeatability(Retention time) RSD≤0.3%
Quantitative repeatability(Area) RSD≤0.6%
Pump  
Flow Rate Range 0.0001-10.000mL/min( increments :0.0001 mL/min)
Max Operating Pressure 45MPa
Pressure Pulsation <0.1MPa( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Accuracy ±0.2%( Test condition: 10MPa , at 1.0ml/min methanol)
Flow Precision RSD≤0.06%( Test condition: 10MPa , at 1.0ml/min methanol)
Gradient Accuracy ±1%
Column Oven  
Temperature Setting Range 5 °C ~ 85 °C
Temperature Stability ≤0.2°C/h
Temperature Controlling Precision ±0.1 °C
Autosampler  
Injection Volume Precision

<0.25%RSD( full loop) ;

<0.5%RSD( partial loop) ;

<1%RSD( no waste)

Linearity >0.999
Cross Contamination(Carry Over) <0.01%
Sample Capacity 120 Samples( 1.5ml vials)
Syringe 250 μL( Standard, with 500μL,1000μL, 2500μL optionals)
Sample Loop 20μL( Standard, with 50μL, 100μL, 200μL optional)

FLD Detector

 
Noise 1×10-5Au
Drift 2×10-4Fu/30min
LOD 5.0×10-10g/mL (naphthalene/methanol)
Wavelength Range 200-650nm
Wavelength Reproducibility ±2 nm
Linearity ≥1.0×104

Features of Liquid Chromatography Instrument
1. Two optional modes: binary high pressure and quaternary low pressure

2. Wavelength scaning: the absorption spectrum can be scanned in the entire range of the light source.

3. A variety of detectors available, such as DAD, ELSD,UVD,RID and FLD.

4. Dual-wavelength detection, two wavelengths canbe detected at the same time. 

 

 

 
 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Anhui Wanyi Science and Technology Co., Ltd.
Location No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Contact Person Annie

Request A Quote

Please check your email address.
Your message must be at least 20 characters.