Wayeal AA23000 Flame Atomic Absorption Spectrophotometer AAS for Metal Elements Analysis
 Introduction of Atomic Absorption Spectrophotometer

Atomic absorption spectrometry (AAS) is an analytical technique that measures the concentrations of elements. Atomic absorption is so sensitive that it can measure down to parts per billion of a gram (µg dm–3) in a sample. The technique makes use of the wavelengths of light specifically absorbed by an element. They correspond to the energies needed to promote electrons from one energy level to another, higher, energy level.

Technical Datas of Atomic Absorption Spectrophotometer

Wayeal Atomic Absorption Spectrophotometer AAS For Metal Elements Analysis
Wavelength range(nm) 185-900nm
Wavelength indication error(nm) ±0.15nm
Wavelength repeatability(nm) ≤0.05 nm
Spectral Bandwidth 0.1, 0.2, 0.4, 1.0, and 2.0nm
Zero Drift ±0.002/30min
Instantaneous noise(Abs) ≤0.002 Abs
Flame Atomizer  
Detection limit Cu: ≤0.002μg/mL
Repeatability RSD≤0.25%
Graphite Furnace Atomizer  
Detection limit(Graphite Furnance: Cd pg) ≤0.3pg
Repeatability RSD≤1.5 %
Heating temperature room temperature -3000°C or so
Heating rate 3000°C/s
Autosampler  
Injection bits 108
Linear >0.999
Injection volume 1-200μL
Injection volume repeatability ≤0. 1%
Result repeatability ≤1.5%
Background correction Deuterium lamp
Lamp position 8

Features of Atomic Absorption Spectrophotometer
1. An 8-lamp holder design alows for simultaneous illumination or preheating to cater to a broader range of customer needs
2. Graphite furnace method automaticaly selects electronic dual-beam
3. One-click operation in the software alows automatic switching between lamp positions; eight lamps can be illuminated or preheated simultaneously, reducing warm-up time and increasing work efficiency
4. Patented encoded lamp feature alows for automatic recognition of element lamps through barcode scanning, which further raises the level of automation in the instrument.

Application Industries of Atomic Absorption Spectrophotometer

Clinical Analysis: Analysing metals in biological fluids such as blood and urine.

Environmental Analysis: Monitoring our environment – eg finding out the levels of various elements in rivers, seawater, drinking water, air, petrol and drinks such as wine, beer and fruit drinks.

Pharmaceuticals: In some pharmaceutical manufacturing processes, minute quantities of a catalyst used in the process (usually a metal) are sometimes present in the final product. By using AAS the amount of catalyst present can be determined.

Industry: Many raw materials are examined and AAS is widely used to check that the major elements are present and that toxic impurities are lower than specified – eg in concrete, where calcium is a major constituent, the lead level should be low because it is toxic.

Mining: By using AAS the amount of metals such as gold in rocks can be determined to see whether it is worth mining the rocks to extract the gold.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Anhui Wanyi Science and Technology Co., Ltd.
Location No. 8, Wenqu Road, High-tech Zone, Hefei, Anhui
Contact Person Annie

Request A Quote

Please check your email address.
Your message must be at least 20 characters.