6W Isolated DC-DC Converter Railway Vehicle Electronic Equipment

Description

URA1D_YMD-6WR3&URB1D_YMD-6WR3 series are isolated 6W DC-DC converter products with 40-160VDC input voltage with eficiencies of up to 86%, input to output isolation is tested with 250VDC and the converter safely operate ambient temperature of- 40℃ to +85℃, input under-voltage protection,output short-circuover-curent,over-voltage protection.They are widely used in railway vehicle applications using 72V,96Vand 110V batery voltages.

 

Features

Ultra-wide 4: 1 input voltage range

High efficiency up to 86%

I/O isolation test voltage: 2.25k VDC

Operating ambient temperfuature range: -40℃ to +85℃

Input under-voltage protection, output short- circuit, over-current, over-voltage protection

Low ripfiple & noise

Input reverse polarity protection available with chassis(A2S ) or Din-Rail mounting (A4S) version

Meets EN50155 railway standard

Industry standard pin-out

 

 

Specificatioin

Selection Guide
Certification Part No. ① Input Voltage (VDC) Output

Full Load

Efficiency④ (%) Min./Typ.

Capacitive

Load⑤

(µF)Max.

Nominal② (Range) Max.③ Voltage (VDC) Current (mA) Max./Min.

 

 

 

EN/BS EN

URA1D05YMD-6WR3

 

 

1 10

(40- 160)

 

 

 

170

±5 ±600/0 78/80 470
URA1D12YMD-6WR3 ± 12 ±250/0 82/84 100
URA1D15YMD-6WR3 ± 15 ±200/0 83/85 100
URB1D05YMD-6WR3 5 1200/0 78/80 1000
URB1D12YMD-6WR3 12 500/0 82/84 470
URB1D15YMD-6WR3 15 400/0 83/85 220
URB1D24YMD-6WR3 24 250/0 84/86 100

Note:

①Use“H”suffix for heat sink mounting,“A2S”suffix for chassis mounting and“A4S”suffix for Din-Rail mounting. We recommend to choose modules with a heat sink for enhanced heat dissipation and applications with extreme temperature requirements;

②The minimum input voltage and starting voltage of A2S and A4S Model are 1VDC higher than those of DIP package due to input reverse polarity protection function;

③Exceeding the maximum input voltage may cause permanent damage;

④Efficiency is measure at nominal input voltage and rated output load; efficiencies for A2S and A4S Model’s is decreased by 2% due to the input reverse polarity protection circuit.

⑤The specified maximum capacitive load for Vo 1 and Vo2 output is identical.

 

 

Input Specifications
Item Operating Conditions Min. Typ. Max. Unit
Input Current (full load / no-load) Nominal input voltage -- 68/3 70/8 A
Reflected Ripple Current Nominal input voltage -- 25 --
Surge Voltage (1sec. max.)   -0.7 -- 180

 

VDC

Start-up Voltage   -- -- 40
Input Under-voltage Protection   28 33 --
Start-up Time Nominal input voltage & constant resistance load -- 10 -- ms
Input Filter   Pi filter
Hot Plug   Unavailable

 

Ctrl * Module on Ctrl pin open or pulled high (3.5- 12VDC)
Module off Ctrl pin pulled low to GND (0- 1.2VDC)
Input current when off -- 3 8 A
Note: *The Ctrl pin voltage is referenced to input GND.
Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Voltage Accuracy① 0%- 100% load -- ± 1 ±3

 

 

 

%

Linear Regulation Input voltage variation from low to high at full load Vo1 -- ±0.2 ±0.5
Vo2 -- ±0.5 ± 1
Load Regulation② 0%- 100% load URB1D_YMD-6WR3 -- ±0.5 ± 1
5%- 100% load Vo1 of URA1D_YMD-6WR3   ±0.5 ± 1
Vo2 of URA1D_YMD-6WR3   ±0.5 ± 1.5
Cross Regulation Dual output, Vo1 load at 50%, Vo2 load at range of 25%- 100% -- -- ± 10
Transient Recovery Time 25% load step change, nominal input voltage   -- 300 500 µs
Transient Response Deviation 5V, ±5V output -- ±3 ±8 %
Others -- ±3 ±5
Temperature Coefficient Full load -- ±0.02 ±0.03 %/℃
Ripple & Noise③ 20MHz bandwidth, 5%- 100% load -- 50 100 mVp-p
Over-voltage Protection Input voltage range 1 10 -- 160 %Vo
Over-current Protection 120 -- 210 %Io
Short-circuit Protection Continuous, self-recovery

Note:

①Vo2 output voltage accuracy of ±5VDC output converter for 0%-5% load is ±5% max;

②URA1D_YMD-6WR3 load regulation for 0%- 100% load is ±5%;

③Under 0% -5% load conditions, ripple & noise does not exceed 5%Vo. The ”parallel cable”method is used for Ripple and Noise test, please refer to DC-DC Converter Application Notes for specific information.

Mechanical Specifications
Case Material Aluminum alloy

 

 

Dimensions

Horizontal package( without heat sink) 25.40 × 25.40 × 1 1.70 mm
Horizontal package( with heat sink) 25.40 × 25.40 × 16.20 mm
A2S wiring package ( without heat sink) 76.00 × 31.50 × 21.20 mm
A2S wiring package( with heat sink) 76.00 × 31.50 × 25.20 mm
A4S rail package( without heat sink) 76.00 × 31.50 × 25.80 mm
A4S rail package( with heat sink) 76.00 × 31.50 × 29.80 mm

 

Weight

Without heat sink Horizontal package/A2S wiring package/A4S rail package 12.5g/36.0g/56.0g (Typ.)
With heat sink Horizontal package/A2S wiring package/A4S rail package 17.0g/40.0g/59.0g (Typ.)
Cooling Methods Free air convection

 

Dimensions and Recommended Layout

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company KHC Power Technology Co.,Ltd
Location 5th Floor, Building B10, Fuqiao 2nd Industrial Zone, Fuhai Street, Bao'an District, Shenzhen
Contact Person Susan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.