1W isolated DC-DC converter with Fixed Input Voltage and Unregulated Single Output

 

Description

B0505MT-1WR4 are specially designed for applications where an isolated voltage is required in a distributed power supply system and especially suitable in applications such as digital circuits,low frequency analog circuits,relay-driven circuits and data switching circuits.

 

 

FEATURES 

  • Ultra-small, ultra-thin DFN package (9.00 x 7.00 x 3.10mm)
  • Isolation capacitance as low as 8pF
  • I/O isolation test voltage 3k VDC
  • Operating ambient temperature range:-40℃ to +125℃
  • High efficiency up to 85%
  • Continuous short-circuit protection
  • AEC-Q100 approved

 

Specifications

 

Selection Guide

 

Certification

 

Part No.

Input Voltage (VDC) Output

Full Load

Efficiency (%) Min./Typ.

Capacitive Load(µF) Max.
Nominal (Range) Voltage (VDC) Current(mA) Max./Min.
UL/EN/IEC B0505MT-1WR4

5

(4.5-5.5)

5 200/20 81/85 2400
Input Specifications
Item Operating Conditions Min. Typ. Max. Unit

Input Current

(full load / no-load)

5VDC input -- 235/7 247/15 mA
Reflected Ripple Current*   -- 10 -- mA
Surge Voltage (1sec. max.) 5VDC input -0.7 -- 9 VDC
Input Filter   Capacitance filter
Hot Plug   Unavailable
Note: * Please refer to DC-DC Converter Application Note for detailed description of reflected ripple current testing method.
Output Specifications
Item Operating Conditions Min. Typ. Max. Unit
Voltage Accuracy   See output regulation curve (Fig. 1)
Linear Regulation Input voltage change: ±1% -- -- 1.2 --
Load Regulation 10%-100% load -- 8 15 %
Ripple & Noise* 20MHz bandwidth -- 30 75 mVp-p
Temperature Coefficient Full load -- ±0.02 -- %/℃
Short-circuit Protection   Continuous, self-recovery
Note: * The “parallel cable” method is used for ripple and noise test, please refer to DC-DC Converter Application Notes for specific information.
General Specifications
Item Operating Conditions Min. Typ. Max. Unit

 

Isolation

Input-output electric strength test for 1 minute with a leakage current of 1mA max. 3000 -- -- VDC
1500 -- -- VAC
Insulation Resistance Input-output resistance at 500VDC 1000 -- --
Isolation Capacitance Input-output capacitance at 100kHz/0.1V -- 8 -- pF
Operating Temperature Derating when operating temperature≥105℃, (see Fig. 2) -40 -- 125
Mechanical Specifications
Case Material Black epoxy resin; flame-retardant and heat-resistant (UL94 V-0)
Dimensions 9.00 x 7.00 x 3.10 mm
Weight 0.5(Typ.)
Cooling Method Free air convection

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company KHC Power Technology Co.,Ltd
Location 5th Floor, Building B10, Fuqiao 2nd Industrial Zone, Fuhai Street, Bao'an District, Shenzhen
Contact Person Susan

Request A Quote

Please check your email address.
Your message must be at least 20 characters.