Reusable Human Body Temperature Sensor For Medical Monitoring Equipment

Price Negotiable
Price: USD 0.1-5 /PCS
MOQ: 1000
Delivery Time: 2-7days
Brand: Jingpu Brand
Product Description

Reusable Human Body Cavity Temperature Sensor for Medical Monitoring Equipment

 

Brief Instruction:

Medical human body cavity temperature sensor ( esophgeal/ rectal temperature probe) be used for human body cavity temperature measurement, Used for the patient monitors. The sensor be composed of epoxy bead and Mono audio plug 6.3mm. Meanwhile, we also accept the customized plug or connector. The rated resistance value 2.252kΩ or 10kΩ. The measured temperature tolerance within ±0.1℃, compatible for replacement YSI400 series sensor.

 

Features:

Epoxy encapsulation

Reusability

Temperature tolerance

(25~45)℃±0.1℃

Operating temperature range: 0℃~50℃

 

Application:

Suitable for medical monitoring equipment

 

Structure and Dimensions:(Unit:mm)

 

NO. Name Material Specification QTY. Remarks
1 Chip NTC 1 /
2 Probe Epoxy Resin 1 gray
3 Wire 24AWG/1C OD3.1 Shielded round sheath wire 1 gray
4 Plug 6.3MP-φ6.3*31-50 1 gray

 

Standard packing (inner packing): 1 pcs/polybag

 

Operation Notice

 

1.Application:Temperature measure ; 

 

2.The current flowing through the NTC is controlled within the Pmax range to avoid the measurement error caused by the self-heating of the component.

 

3.Avoid excessive heat shock,The hot air blow should beat least 30mm to the probe in case heat shrink protection tube need to be attached.

 

4.Storage Temperature 0℃~50℃,30%~80%RH;Avoid in a corrosive gas and sunlit environment; After opening the package, it needs to be sealed again.

 

5.According to the structure of Glass coating NTC thermistor, when end user install, to avoid the epoxy head subjected too much tensile force and bending force from the lead wire,The lead wire shall be controlled at a bending point or a force point on a lead wire 6mm or less below the sealing head.So as not to hurt the chip, resulting in resistance drifting and even open circuit, especially when the component is heated.

 

Product Picture:

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Hefei Jingpu Sensor Technology Co., Ltd
Location Building No.2, Jinhui Photoelectric Industrial Park, Intersection of Paihe Avenue and Jixian Rd, Feixi, Hefei, Anhui, China
Contact Person LIU HUI

Request A Quote

Please check your email address.
Your message must be at least 20 characters.